← Board

9 Piopio Street Lake Hawea 9382

Queenstown Lakes · property 197230 · LOT 62 DP 624962 - 0.061400 Ha CT- 1270163

Every consent eDocs lists on this property

Consent Description Applicant Status Status date
BC261487 Building Construction Of A Single Storey Detached Dwelling With Attached Double Garage. Application Complete

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of BC261487 read 18 Nov 2026

Value of work
$210k estimated on the application form, GST included
Lodged by
Peetah Schist (Agent)
peetah.schist@a1homes.co.nz
03 377 9051
Applicant
Owner
rdjoyce1@gmail.com
021 213 6271
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • Cedar Cladding nogs @ 480crs max 140x45 H1.2 frame +140x45 top plate, studs @ 600crs max, nogs @ 480crs.
  • Cedar Cladding nogs @ 480crs max Scyon Stria OR Oblique Cladding:
  • James Hardie Stria Vertical weatherboards installed, flashed and finished to the latest James Hardie specifications and in accordance with NZBC: E2/AS1 External Moisture.
  • Selected Cedar Vertical Shiplap, Various sized cladding on CAVIBAT battens, installed, flashed and finished to the latest Manufacturers specifications and in
  • Vertical Shiplap Cedar 9.92 m2 9.92 m2
  • 1. Fibre cement weatherboard over nominal 20mm drained cavity 2. Rusticated timber weatherboard over nominal 20mm drained
  • Vertical Shiplap Cedar - Western Red HP55 Roof Cladding:
  • 4 Weatherboards, exterior joinery and 14 – 18 14 – 18 14 – 18 finishing timbers
  • b) For timber weatherboards and exterior joinery, 20% at the time of painting,
  • Vertical Shiplap Weatherboard
  • Weatherboards beyond the point where BRANZ bulletin 411 compliant Weatherboard lap or rebate combinations terminate at the corner junction.
  • CLADDING DETAIL - INTERNAL CORNER - CEDAR CLADDING DETAIL - EXTERNAL CORNER - CEDAR DO NOT scale off drawings. Cross reference all drawings. Any discrepancies MUST be clarified
  • Cavity Fix Vertical Shiplap Weatherboard System Notes:
  • CLADDING DETAIL - INTERNAL CORNER - CEDAR CLADDING DETAIL - EXTERNAL CORNER - CEDAR Vertibat or Cavibat Cavity
  • Cavity Fix Vertical Shiplap Weatherboard System 1 : 2 @ A4 16/10/2017
  • CEDAR EXTERNAL CORNER CEDAR INTERNAL CORNER
  • CEDAR SOFFIT DO NOT scale off drawings. Cross reference all drawings. Any discrepancies MUST be clarified
  • Cavity Fix Vertical Shiplap Weatherboard System - Refer to NZBC Acceptable Solution E2/AS1 Table 21 for the separation
  • CEDAR SOFFIT back flashing
  • 20 James Hardie Linea™ Oblique™
  • Weatherboard Vertical Installation Technical Specification July 2018 Figure 10: Internal corner
  • Figure 9: Vertical joint 300mm weatherboard width EH wind zone and SED James Hardie Linea™
  • Weatherboard Vertical Installation Technical Specification July 2018 New Zealand 21 Figure 11: External aluminium box corner
  • James Hardie Linea™ Oblique™
  • Weatherboard Vertical Installation Technical Specification July 2018 New Zealand 17 Figure 4: Soffit detail
  • OBLIQUE/CEDAR INTERNAL CORNER Rigid wall underlays shall (required in Extra High wi
  • battens & weatherboards to be fixed to. DO NOT scale off drawings. Cross reference all drawings. Any discrepancies MUST be clarified
  • OBLIQUE/CEDAR INTERNAL CORNER Rigid wall underlays shall (required in Extra High wind z
  • battens & weatherboards to be fixed to. Figure 11: Exter
  • VERTICAL STRIA /CEDAR INTERNAL CORNER DO NOT scale off drawings. Cross reference all drawings. Any discrepancies MUST be clarified
  • of bevelback w/board cladding Stage #3
  • of bevelback w/board cladding apron flashing
  • of bevelback w/board cladding Seal all round to
  • that the weatherboard is hard against the back of
  • CEDAR WINDOW HEAD CEDAR WINDOW JAMB DO NOT scale off drawings. Cross reference all drawings. Any discrepancies MUST be clarified
  • CEDAR WINDOW SILL DO NOT scale off drawings. Cross reference all drawings. Any discrepancies MUST be clarified
  • HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM JAMES HARDIE® STRIA™ CLADDING
  • 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM This section relates to the supply and fixing of Hermpac Vertical cladding:
  • Vertical Shiplap weatherboards Board and Batten weatherboards
  • Vertical Shiplap 'Vertibat' cavity batten systems 1.1 ABBREVIATIONS AND DEFINITIONS
  • NZS 3617 Profiles of weatherboards, fascia boards and flooring JAS-ANZ CodeMark Certification CMNZ30036 - Hermpac VertiLine Vertical Shiplap Weatherboard
  • Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System installation Specifications Hermpac Vertical Shiplap Weatherboard Direct Fix System Installation Specifications
  • Hermpac Product Technical Statement (PTS) – VertiLine Vertical Shiplap Weatherboard Cavity System (July 2023)
  • Hermpac Product Installation Checklist – VertiLine Vertical Shiplap Weatherboard Cavity System (Jan 2023 V2)
  • Hermpac Board and Batten Weatherboard Cavity System Installation Specifications Hermpac Board and Batten Weatherboard Direct Fix System Installation Specifications
  • Hermpac Product Technical Statement (PTS) – Board and Batten Weatherboard Cavity System (July 2023)
  • Hermpac Product Installation Checklist – Board and Batten Weatherboard Cavity System (Jan 2023 V2)
  • Hermpac WR & Yellow Cedar cuts and characteristics iDesign Architecture Joyce 362332
  • © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 64 of 143 2 PRODUCTS
  • BRANZ Appraisal 650 - Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System Manufacturer/supplier contact details:
  • 5 years For installation of Hermpac vertical weatherboard cladding systems Provide this warranty on the installer/applicator standard form (if not available then use the
  • Hermpac vertical weatherboard cladding systems meet the requirements of the NZBC when used within the Conditions and Limitations of their Certificate CMNZ30036.
  • 2.1 VERTICAL SHIPLAP / VERTICAL BOARD AND BATTEN Weatherboards to Hermpac profiles, Lap and Rebate details to BRANZ BU 411 and general design
  • wood-based building components to achieve a 15-year durability performance. Weatherboards in lengths relevant to profile selection and application, with all unsound and open split knots excluded
  • © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 65 of 143 Acceptable Solution is limited to the following types of weatherboards and their derivatives:
  • Vertical Standard Shiplap and Hermpac Custom Profiles Vertical Standard Board and Batten and Hermpac Custom Profiles
  • A selection of the above profiles are also available in Western Red Cedar and Yellow Cedar finger-joint (CedarOne Evolve and CedarLine Evolve). CedarOne Evolve is quarter-sawn cut Cedar.
  • CedarLine Evolve is primarily flat-sawn cut Cedar. Evolve profiles are available across most standard and custom profiles. The timber is machined with a “combed” finish to the front face and
  • Western Red Cedar and Yellow Cedar. Profiles are machined with a “dressed” finish to the front face and the exposed corners are machined to paint quality - PQ (ie. rounded edges for paint
  • © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 66 of 143 3 EXECUTION
  • relative to visible edge of board. For vertical shiplap boards, where possible the exposed lap should face away from the prevailing wind.
  • Hermpac Western Red Cedar, Yellow Cedar or DuraLarch™ weatherboards fixed with Stainless Steel or Silicon Bronze Hermpac Crown, Rose and Flat Head nails or Hermpac Starcap screws and
  • Kanda weatherboards fixed with Hermpac Starcap screws are limited to use in NZS 3604 Wind Zones up to and including Extra High when dwangs or structurally fixed Vertibat cavity battens are
  • © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 67 of 143 4 SELECTIONS
  • Hermpac Western Red Cedar weatherboards fixed with stainless steel jolt head nails are limited to use in NZS 3604 Wind Zones up to and including Medium when dwangs or structurally fixed Vertibat
  • Hermpac Yellow Cedar and DuraLarch™ weatherboards fixed with jolt head nails are limited to use in NZS 3604 Wind Zones up to and including Extra High when dwangs or structurally fixed Vertibat
  • 3.9 FIXING VERTICAL SHIPLAP WEATHERBOARDS Install level, true to line and face, to NZBC E2/AS1, 9.4 Timber weatherboards. Single face fix
  • weatherboards to every fixing point, clear of the adjacent lapped board. Fixing to be driven in with a slightly upward slope. Line fixings horizontally across the boards. Pilot drill all fixings slightly
  • Hermpac Construction Drawings for accurate weatherboard fixing information. Using a Hermpac specialty clinch nail, prior to the next row of Vertical Shiplap boards being fixed
  • clinch nail into the cavity batten so that the clinch head settles flush into the weatherboard's surface. The clinch nail head must not sit proud of the timber surface nor prevent the correct separation of
  • each adjacent row of boards. Do not pin laps or weatherboard faces. Refer to Hermpac Construction Drawings and Installation Specification for suitable face fixings
  • Kanda weatherboards must be fixed with Hermpac Starcap screws), correct placement of fixings, size, length and minimum penetration requirements, and for external and internal corner
  • 3.11 APPLYING SEALANT TO BACK FLASHINGS & WEATHERBOARDS - SIKA Wipe weatherboard surfaces with a clean rag. Using an abrasive pad, rub down back flashings in a
  • weatherboards. Apply a continuous 5mm bead of adhesive to back flashing prior to fixing weatherboards.
  • © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 68 of 143 1 GENERAL

Plans (PDF, 16.5MB)Project Specification (PDF, 1.6MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.