2 Grand Terrace Square Arrowtown 9302
Queenstown Lakes · property 189830 · changed title from 1014570 on 28/09/22; changed title from 1043574 on 04/01/24; changed title from 1158641 on 14/10/24; changed from 1174429 on 17/06/25
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| RM260491 Resource | Application To Construct A Residential Unit In Area R16 Of Millbrook And Partially Outside A Building Platform With Breach Of Earthworks Standards At 2 Grand Terrace Square, Queenstown | The Crang Family Trust | Decision Issued | 2 Jun 2026 |
| MN260491 | The Crang Family Trust - Application To Construct A Residential Unit In Area R16 Of Millbrook And Partially Outside A Building Platform With Breach Of Earthworks Standards At 2 Grand Terrace Square, Queenstown | Awaiting Officer Review | ||
| BC261473 Building | Construction Of A In Part 2 Storey Detached Dwelling With Attached Garage. | PIC/PIM Issued |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of RM260491 read 19 Nov 2026
- Lodged by
- Not named on the application form
- Timber cladding
-
- The finish of the walls are Millbrook stone with bagged plaster and cedar. The windows including the skylights, will be wooden joinery with low reflectivity glass, Windows on
AEE - 2 Grand Terrace Square (PDF, 7.3MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.
- Not read
- no correspondence section in: Attachment A - Form 9 revised; Attachment A - Form 9; Email from agent with application form - 28.04.26
From the documents of BC261473 read 18 Nov 2026
- Value of work
- $4m estimated on the application form, GST included
- Designer
- Sam Baxter / Yuchung Chang
yuchung@sumichchaplin.com
09 522 1286 - Engineer
- Andrew Thompson
andrew.thompson@envelope-eng.co.nz
027 234 1107 - Licensed: Design
- Sam Baxter
- Licensed: Design
- Andrew Thompson
- Lodged by
- Yuchung Chang (Architect)
yuchung@sumichchaplin.com
09 522 1286 - Applicant
- Owner
vaughan@crangcivil.co.nz
021 910 411
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- Rosenfeld Kidson (ITI) bandsawn vertical shiplap Accoya weatherboard for selected Charred finish by Blackwood Project.
- Refer to larger details for use of RK56 weatherboard profiles, RKA94 (65mm) corner mouldings. Weatherboards cladding system fixed on
- framed structure. Weatherboard setout to be as per the elevations. All timber to be quarter sawn (vertical grain). All fixings to be silicon
- Weatherboard cladding system to be in accordance with Rosenfeld Kidson (ITI) specification and details. Proprietary RK aluminium
- Joinery to be made from A-Grade Western Red Cedar (clears). Window sills to be made from A-Grade Western Red Cedar (clears)
- Accoya W/B panels. Refer to note 4221. Garage door tracks, support brackets, door sub frame and hinges to be powdercoated
- 90mm or 140mm framing as shown with ITI Accoya Board for Charred Finish 165 x 18mm vertical shiplap profileover 20mm cavity over rigid air
- Cedar Timber Joinery with DGU. TIMBER FRAMING SIZES & CENTRES (AS PER NZS3604)
- or @ 400crs for Vertical Cedar Weatherboards. NEW INTERNAL TIMBER FRAMED WALL
- @ 400crs for Vertical Cedar Weatherboards. TOP & BOTOM PLATE FIXING
- 0401 Cedar Cladding External Corner SCALE 1:5
- Weatherboard Cladding Base Detail SCALE 1:5
- Cedar Cladding to Plaster Wall Junction SCALE 1:5
- DRESSED CEDAR TO EDGES OF G DOOR
- CEDAR BOARD CONNECTION ALONG THE TOP OF THE GARAGE DOOR.
- RK71 135x18mm CEDAR FASCIA BOARD FOR SELECTED STAIN
- Flat Roof to Timber Cladding SCALE 1:5
- Barge Flashing for Timber Cladding SCALE 1:5
- 90x200 CEDAR CEILING BEAMS @ 600crs FOR SELECTED STAIN FINISH.
- RK ITI VERTICAL WEATHERBOARDS JAMES HARDIE® SOFFITS
- 4221CV RK ITI Vertical Weatherboards 4239JH James Hardie® Soffits
- 4221CV RK ITI VERTICAL WEATHERBOARDS This section relates to the supply and fixing of RK ITI Vertical weatherboard cladding systems.
- Vertical shiplap weatherboards Vertical board & batten cladding
- NZS 3617 Profiles of weatherboards, fascia boards and flooring NZS 3631 NZ Timber Grading Rules
- BRANZ BU 411 Recommended timber cladding profiles CodeMark Certificate CMNZ70080 ver3 - RK Board & Batten
- © CIL Masterspec Oct 2026 4221CV RK ITI VERTICAL WEATHERBOARDS | Page 74 of 319 1.4 MANUFACTURER/SUPPLIER DOCUMENTS
- RK VERTICAL 20mm - Vertical Shiplap Weatherboards V5, October 2020 RK VERTICAL 45mm - Vertical Shiplap Weatherboards V5, October 2020
- RK Board & Batten Weatherboards V1.0, November 2020 Vertical Shiplap Weatherboard - 20 mm Cavity on Flexible Underlay - Drawing Set 12 October 2020
- Vertical Shiplap Weatherboard - 20 mm Cavity on Rigid Underlay - Drawing Set 12 October 2020 Vertical Shiplap Weatherboard - 45 mm Cavity on Flexible Underlay - Drawing Set 12 October 2020
- Vertical Shiplap Weatherboard - 45 mm Cavity on Rigid Underlay - Drawing Set 12 October 2020 Board & Batten Weatherboard - Direct Fixed on Flexible Underlay - Drawing Set 12 October 2020
- Board & Batten Weatherboard - 20mm Cavity on Flexible Underlay - Drawing Set 12 October 2020 RK Timbers Factory Oil Maintenance Guide
- Sika Methodology - RK Timbers powder coated flashing to cedar bonding Manufacturer/supplier contact details
- 5 years For installation of Vertical weatherboard cladding systems Provide this warranty on the installer/applicator standard form (if not available then use the
- RK Vertical 45mm Weatherboard cladding systems meet the requirements of the NZBC when used within the Conditions and Limitations of their Certificates CMNZ70082.
- © CIL Masterspec Oct 2026 4221CV RK ITI VERTICAL WEATHERBOARDS | Page 75 of 319 2 PRODUCTS
- RK Vertical 20mm Weatherboard cladding systems meet the requirements of the NZBC when used within the Conditions and Limitations of their Certificates CMNZ70083.
- 2.1 TIMBER SPECIES - WESTERN RED CEDAR Canadian Western Red Cedar (Thuja Pilcata).
- 2.3 RK TIMBERS VERTICAL WEATHERBOARDS Timber weatherboards to RK Timbers Standard and Architectural profiles. General design to NZS
- © CIL Masterspec Oct 2026 4221CV RK ITI VERTICAL WEATHERBOARDS | Page 76 of 319 3 EXECUTION
- Dryden WoodOil timber finish, applied onto all faces of the timber weatherboards, fascia, timber corners, boxed corner cover boards, mouldings and scribers. Refer to SELECTIONS.
- Sansin PrecisionCoat timber finish, applied onto all faces of the timber weatherboards, fascia, timber corners, boxed corner cover boards, mouldings and scribers. Refer to SELECTIONS.
- Paint coatings applied onto all faces of the timber weatherboards, fascia, timber corners, boxed corner cover boards, mouldings and scribers. Refer to SELECTIONS.
- Dryden WoodOil timber finish, factory spray-applied onto all faces of the timber weatherboards, fascia, timber corners, boxed corner cover boards, mouldings and scribers.
- © CIL Masterspec Oct 2026 4221CV RK ITI VERTICAL WEATHERBOARDS | Page 77 of 319 3.7 FACTORY COATING - STAIN FINISH
- Sansin PrecisionCoat timber finish, spray-applied onto all faces of the timber weatherboards, fascia, timber corners, boxed corner cover boards, mouldings and scribers.
- weatherboards, fascia, timber corners, boxed corner cover boards, mouldings and scribers. Application - cavity battens
- Application - vertical shiplap weatherboards 3.14 INSTALL WEATHERBOARDS - 20mm CAVITY BATTENS
- Seal all cut edges prior to installation. Start fixing vertical shiplap weatherboards from an internal or external corner with leading board lap (top lap) pointing in the same direction as the prevailing wind.
- Weatherboards to be full storey height, full width and continuous in length at jamb to head and sill junctions with minimum 50mm overhang of bottom plate and finish a minimum 100mm above paved
- Application - internal corners - vertical shiplap 3.15 INSTALL TIMBER INTERNAL CORNER PROFILES
- Application - external corners - vertical shiplap 3.16 INSTALL TIMBER EXTERNAL CORNER PROFILES
- © CIL Masterspec Oct 2026 4221CV RK ITI VERTICAL WEATHERBOARDS | Page 78 of 319 4 SELECTIONS
- © CIL Masterspec Oct 2026 4221CV RK ITI VERTICAL WEATHERBOARDS | Page 79 of 319 1 GENERAL
Plans (PDF, 50.0MB)Project Specification (PDF, 3.2MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.