6 Rinsary Lane Lake Hawea 9382
Queenstown Lakes · property 176680 · LOT 3 DP 608803 - 0.175300 Ha CT- 1201628
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| RM260457 Resource | Application To Construct A Residential Unit Exceeding 15% Building Coverage Requirements By 2% At 6 Rinsary Lane, Lake Hawea | K Roulston And O’Malley & Co Nominees Limited | Decision Issued | 7 May 2026 |
| MN260457 | K Roulston And O’Malley & Co Nominees Limited - Application To Construct A Residential Unit Exceeding 15% Building Coverage Requirements By 2% At 6 Rinsary Lane, Lake Hawea | Awaiting Officer Review | ||
| BC261270 Building | Construction Of Single Storey Dwelling With Attached Garage | Waiting for Further Information |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of RM260457 read 19 Nov 2026
- Lodged by
- Alex Dunn - The Property Group
adunn@propertygroup.co.nz
027 335 6325 - Applicant
- K Roulston And O’Malley & Co Nominees Limited
roulston@xtra.co.nz
027 224 2898
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- Thermo Brushed Nordic Pine 135x20mm Timber Cladding (Ver cal Profile) on 20mm cavity
Appendix C - Plans (PDF, 2.6MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.
From the documents of BC261270 read 18 Nov 2026
- Licensed: Design
- Joshua Scott BP136158
- Lodged by
- Not named on the application form
josh@huskdd.co.nz
027 884 2922 - Applicant
- Owner
roulston@xtra.co.nz
027 224 2898
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- Thermo Brushed Nordic Pine 135x20mm Timber Cladding (Ver cal Profile) on 20mm cavity
- JSC TMT Weatherboard Cladding........................................................................................52 Ecoply Barrier ......................................................................................................................55
- 3617:1979(NZS) Specification for profiles of weatherboards, fascia boards, and flooring
- - Cedar Clears (Western Red Cedar, Thuja plicata) - Rimu - (NZ Red Pine)
- upwards to the ridge. Extend no more than 20mm into gutters. Provide a minimum 150mm shiplap at side and end laps, ensuring all laps are formed to shed water to the exterior. The underlay must be
- 3.11 JSC TMT Weatherboard Cladding 3.11.1 Scope
- JSC Cladding Systems comprises: weatherboards installed over H3.2 treated timber castellated cavity battens to form either a 20mm cavity or a 45 mm cavity, fascia boards and moulding profiles.
- 3.11.3 Weatherboard Type & Profile Vertical Shiplap Cladding System
- Store weatherboards and accessories undercover, flat and clear of the ground in accordance with JSC Husk Design + Draft K Roulston Residence Issued for Consent
- not install weatherboards when wet. Contact JSC Architectural Team for complete system fixing details and installation guidelines:
- at the time of weatherboards installation, and that any additional framing required for fixing at corners, openings and soffits is correctly in place. Ensure that the building wrap or rigid air barrier as
- vent strip are correctly installed and appropriate for the weatherboards installation, and in complete accordance with JSC requirements.
- Ensure set-out of weatherboards allows for a 2mm expansion gap between lapped boards. All nail fixings are to be pre-drilled a minimum of 1mm diameter smaller than the nail gauge. Face fix
- weatherboards with a single nail at each fixing point, with nails driven in a slight (2°+) upward slope, 35mm from the overlapping edge of the weatherboard. Nails shall achieve a minimum 30mm
- Do not pin laps of weatherboards. Clinch nails may be used for temporary fixing. 3.11.8 Installation
- Weatherboard flashing material compatibility shall be in accordance with NZBC E2/AS1 2.2, and as shown on the drawings.
- Check that the specified JSC TMT® Weatherboard cladding system has been correctly installed and fixed to the layout and details shown on the drawings; that all joints, associated trim and accessories
Architectural Plans (PDF, 14.4MB)Project Specification (PDF, 0.9MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.