37 Devon Street Arrowtown 9302
Queenstown Lakes · property 9141 · Lot 17 DP 11754 - 0.052400 Ha CT- OT3C/807
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| PM260171 | Cancelled Alterations To Existing Dwelling, No Change To Footprint. | Cancelled | ||
| BC261405 Building | Alterations And Change Of Use Of Existing Residential Detached Dwelling To Multiunit Dwelling. New Roofing, External Cladding, Internal Layout Change And New Deck. | Waiting for Further Information | ||
| BC260471 Building | Alteration To Existing Dwelling: Supply & Install Of New Wood Burner Fireplace. | CCC Issued | 16 Jun 2026 | |
| BC950096 Building | Extend Existing Residence | CCC Issued | 2 Apr 2001 |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of BC261405 read 18 Nov 2026
- Value of work
- $250k estimated on the application form, GST included
- Lodged by
- Steve Henderson NZCAD Ltd (Agent for Consent Purposes)
steve@nzcad.co.nz
021 424 322 - Applicant
- Owner
nic@dentconstruction.co.nz
0221406932
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- Owner selected Bevel Back Weather Board profile to NZS 3617 Cavity
- Bevel Back Weather Board Expol R1.4 (45mm) EPS
- Back Weatherboard - Profile to NZS 3617
- Envira Bevel Back Technical Installation Specifications. Title:
- Refer to Detail Option A Envira Bevelback weatherboard Head detail
- Envira Bevel Back WeatherBoards 187x18mm Envira cavity Batten 44x20mm drained cavity
- Timber Weatherboard Cladding..........................................................................................24 Cladding & PreCladding ...........................................................................................................28
- 3617:1979(NZS) Specification for profiles of weatherboards, fascia boards, and flooring
- Shiplap spaced 9mm. 2.5.4 Panel Finish Coating
- 2.9 Timber Weatherboard Cladding 2.9.1 Scope
- Supply and install the selected Timber Weatherboard Cladding type(s) to the locations shown on the drawings, complete with all accessories. All aspects of this work shall be carried out to comply with
- The following is a list and a general description of the extent of Timber Weatherboard Cladding work, which are more specifically defined in the contract documents, required for the completion of the
- 2.9.2 Horizontal Weatherboard Profile Standard Bevel-back Weatherboard: ex.200mm x 25mm, machined to NZS 3617 and/or BRANZ
- Standard Bevel-back Weatherboard shall be run from H3.1 treated, finger-jointed dressing-grade Pinus Radiata. Durability shall be to NZS 3602 Table 2A and NZBC B2/AS1, and materials compatibility
- Handle the weatherboards carefully to avoid damage to edges and faces, store flat and keep Proposed Alterations to Probst
- 2.9.4 Weatherboard Finish Standard Bevel-back Weatherboards run from H3.1 treated Pinus Radiata shall be pre-primed to
- Co-ordinate with other trades to ensure that the weatherboards correctly allow for door and window installation, and for the locations of pipes, outlets, and fittings installed by others.
- Horizontal Weatherboards Cavity-Fixed on Timber Framing - check all aspects of preparatory works, including, but not limited to:
- is correctly in place, and has a maximum moisture content of 20% at the time of weatherboard cladding installation.
- weatherboard cladding installation. - For cavity construction without a rigid wall underlay and where the studs are at greater than
- works have been completed that will enable the weatherboards to be installed, and that the work of other trades does not negatively impact on or reduce the minimum clearances required by the NZ
- Fix pre-primed Pinus Radiata Standard Bevel-back Weatherboards with hot-dipped galvanised jolt head nails, length to embed minimum 35mm into the framing, holes pre-drilled 1mm less than the
- Install the weatherboards with one nail positioned 10mm above the top of the lower board at each stud. Punch nails 3mm below the board surface, prime nail holes and fill prior to sand and finishing.
- Fix pre-primed Standard Bevel-back Weatherboards with Grade 316 stainless steel, annular grooved jolt head nails, length to embed minimum 35mm into the framing, holes pre-drilled 1mm less than
- 2.9.8.1 Bevel-back Weatherboard - Cavity Fix Back flash all internal and external corners as detailed.
- Carefully set-out Standard Bevel-back Weatherboard cladding horizontally over the cavity battens and fix the base weatherboard to the framing, level and true to line along the base line, 50mm minimum
- weatherboards over the cavity battens and fix to the framing, keeping cladding lines consistent, level and true along walls and around corners.
- Install full length weatherboards where possible. Where joints are unavoidable, scarf the weatherboards at 45º and fix to solid framing through the overlapping board just clear of scarf join -
- stagger weatherboard joints to avoid clustering. Where boards are coated, ensure all cut ends and fresh timber is double coated with a suitable sealer/primer.
- Finish Standard Bevel-back Weatherboards, weatherboard trim, flashings and accessories at internal and external corners, window and door openings, parapets, and at junctions with other building
- Upon delivery to site, inspect weatherboards and accessories and reject any items found to be damaged, defective or substandard. Contact the manufacturer/supplier for replacement.
- Store weatherboards, flashings and accessories undercover, flat and true, clear of the ground by at least 150mm and supported on dry, clean timber bearers at maximum 900mm centres, or as
- recommended by the weatherboard manufacturer. Keep stored materials and accessories dry and protected from damage and contamination at all times, and free from bending, distortion or excessive
- Do not use damaged or defective weatherboards or accessories. Dock any oversized knots, unacceptable grade characteristics or damaged areas of weatherboard.
- Weatherboards must be dry prior to installation. Do not install weatherboards during periods of wet weather. Seal all cut ends and fresh-cut timber with two coats of the selected exterior primer or
- Handle weatherboards in accordance with the manufacturer's recommendations and in a manner that prevents damage to or deterioration of the material, including surface marking.
Plans (PDF, 4.6MB)Project Specifications (PDF, 8.1MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.
From the documents of BC260471 read 19 Nov 2026
- Value of work
- $4k estimated on the application form, GST included
- Builder
- Dent Construction
nic@dentconstruction.co.nz
0221406932 - Lodged by
- Not named on the application form
- Applicant
- Owner
nic@dentconstruction.co.nz
0221406932
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
- Not mentioned in the documents read