26 Panners Way Queenstown 9300
Queenstown Lakes · property 5362 · Lot 1 DP 25043 - 0.107100 Ha CT- OT17A/333
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| RM260780 Resource | Consent Is Required For Two New Residential Units Where Land Use Consent Is Sought For Various Built Form Breaches. Subdivision Consent Is Sought To Allow The Existing Residential Unit On The Site To Be Held In One Title, With The Two New Residential Units Proposed By Way Of This Consent To Be Held In One Title At 26 Panners Way, Queenstow | S Austin | Decision Issued | 17 Sep 2026 |
| EA260780 | S Austin - Engineering Acceptance In Relation To - Consent Is Required For Two New Residential Units Where Land Use Consent Is Sought For Various Built Form Breaches. Subdivision Consent Is Sought To Allow The Existing Residential Unit On The Site To Be Held In One Title, With The Two New Residential Units Proposed By Way Of This Consent To Be Held In One Title At 26 Panners Way, Queenstow | Being Vetted | ||
| DR260780 | S Austin - Consent Is Required For Two New Residential Units Where Land Use Consent Is Sought For Various Built Form Breaches. Subdivision Consent Is Sought To Allow The Existing Residential Unit On The Site To Be Held In One Title, With The Two New Residential Units Proposed By Way Of This Consent To Be Held In One Title At 26 Panners Way, Queenstow | Development Contribution Notice Sent | ||
| BC261406 Building | Addition To Existing Garagesleepout And Construction Of Two Storey Dwelling With Connecting Corridor To Existing Garagesleepout To Create 6 Bedroom, 4 Bathroom Dwelling | Waiting for Further Information | ||
| BC071086 Building | Construct New Wall | CCC Issued | 30 Oct 2007 | |
| BC055837 Building | Alteration To Existing Dwelling To Increase Living Space On | CCC Issued | 29 Jun 2007 | |
| RM020092 Resource | Undertake Earthworks For A House And Garage At Panners Way, Larch Hill, Queenstown | M & P Jamieson | Issued | 10 May 2002 |
| BC960126 Building | Re-Alignment Of Stormwater Drainage | CCC Issued | 31 May 2007 | |
| BC950747 Building | Realine Sewer Services & Provide Services | CCC Issued | 6 Sep 1995 | |
| RM940943 Resource | Subdivision To Create Lots 1 & 2 New Dp 25043 | M Jamieson | Issued | 21 Feb 1994 |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of RM260780 read 19 Nov 2026
- Lodged by
- Alex Dunn - Southern Planning Group
alex@southernplanning.co.nz
0278402855 - Applicant
- S Austin
samualaustin@gmail.com
0277496760
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
- Not mentioned in the documents read
From the documents of BC261406 read 18 Nov 2026
- Value of work
- $800k estimated on the application form, GST included
- Designer
- Michael Macfie
michael@macfiearchitecture.co.nz
0221921415 - Engineer
- Alyx Hodgson (DHC)
alyx@dhc.co.nz
0211120973 - Licensed: Design
- Michael Macfie BP116717
- Lodged by
- Macfie Architecture Ltd (Designer)
michael@macfiearchitecture.co.nz
0221921415
093796687 - Applicant
- Owner
samualaustin@gmail.com
0277496760
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- HORIZONTAL TIMBER CLADDING OVER 20MM CAVITY CLADDING:
- TIMBER CLADDING TO MATCH EXISTING JOINERY:
- 7. TIMBER BEVEL BACK WEATHERBOARDS : Weathertex weatherboards over 20mm H3.1 cavity battens over
- WEATHERBOARDS WITH MS SEALANT NATURAL STONE VENEER
- SELECTED WEATHERTEX WEATHERBOARDS FLASHING TAPE TO SEAL OVERLAP OF NEW TO OLD BUILDING WRAP -
- SELECTED WEATHERTEX WEATHERBOARDS SILICONE SEALANT
- SEAL AND GLUE TO ADJACENT WEATHERBOARDS WITH MS SEALANT & WEATHERTEX LARGE END STOP
- SELECTED WEATHERTEX WEATHERBOARDS SELECTED CAVITY BATTEN
- WEATHERTEX WEATHERBOARDS ALUMINIUM HEAD FLASHING WITH MINIMUM 15 DEGREE FALL
- WEATHERTEX WEATHERBOARDS SELECTED DOUBLE GLAZED ALUMINIUM JOINERY
- WEATHERTEX WEATHERBOARDS line of head flashing over
- SELECTED TIMBER BEVELBACK WEATHERBOARDS H3.1 PRE-PRIMED GROOVED TIMBER FACING
- SELECTED WEATHERTEX WEATHERBOARDS TIMBER FRAMING
- SELECTED WEATHERTEX WEATHERBOARDS OPTION FOR BOXED CORNER DETAIL:
- SELECTED WEATHERTEX WEATHERBOARDS PAINTED WEATHERBOARD
- SELECTED WEATHERTEX WEATHERBOARDS SELECTED 20MM CAVITY BATTENS
- SELECTED TIMBER BEVELBACK WEATHERBOARDS SELECTED CAVITY BATTEN
- WEATHERBOARDS. PAINT FINISH 90x40 JOLT HEAD NAIL, STST FIXING AS PER TABLE 24 E2/AS1, MATERIAL
- PAINTED DIRECT FIXED WEATHERBOARD 35MM MIN FRAMING PENETRATION,
- WEATHERTEX WEATHERBOARDS TO MATCH DWELLING PROFILE NEW H3.2 90 X 90 STRUCTURAL POSTS @ 1000 CTRS MAX
- SELECTED BEVELBACK WEATHERBOARD SELECTED BUILDING UNDERLAY
- SELECTED BEVEL BACK WEATHERBOARDS CONTINUOUS SEALANT OVER PEF ROD
- WEATHERTEX WEATHERBOARDS SELECTED BUILDING UNDERLAY
- Selected bevel back weatherboards Selected timber packer to suit
- Selected timber bevelback weatherboards Pipe penetration sloping to the outside
- ITI NZ WEATHERTEX HORIZONTAL WEATHERBOARD WALL CLADDING
- 4222WH ITI NZ Weathertex Horizontal Weatherboard 4239JH James Hardie® Soffits
- 4222WHITI NZ WEATHERTEX HORIZONTAL WEATHERBOARD This section relates to the supply and fixing of ITI NZ Ltd Weathertex, horizontal weatherboard
- Weathertex Selflok or Primelok weatherboards. All associated cavity battens, flashings, accessories and fixings to complete installation.
- BRANZ Appraisal 511 (2020) Weathertex Direct Fixed Weatherboard Cladding Systems - Amended 19 June 2025
- BRANZ Appraisal 512 (2020) Weathertex Cavity Fixed Weatherboard Cladding Systems - Amended 19 June 2025
- Weathertex New Zealand Installation Manual - Selflok Weatherboards (Dec 2024) Weathertex New Zealand Installation Manual - Primelok Weatherboards (Dec 2024)
- Weathertex Construction Details - Primelok Weatherboards - Direct Fix Construction Weathertex Construction Details - Primelok Weatherboards - Cavity Fix Construction
- Weathertex Construction Details - Selflok Weatherboards – Direct Fix Construction Weathertex Construction Details - Selflok Weatherboards – Cavity Fix Construction
- © CIL Masterspec Oct 2026 4222WH ITI NZ WEATHERTEX HORIZONTAL WEATHERBOARD | Page 97 of 213 Company: ITI NZ Limited
- 25 years For Weathertex Selflok and Primelok weatherboards, factory primed
- 15 years For Weathertex Selflok weatherboards, natural finish For associated components and accessories.
- Weathertex Direct Fixed Weatherboard Cladding System has been appraised as meeting provisions of the NZBC when used within the Conditions and Limitations of its BRANZ Appraisal 511.
- Weathertex Cavity Fixed Weatherboard Cladding System has been appraised as meeting provisions of the NZBC when used within the Conditions and Limitations of its BRANZ Appraisal 512.
- © CIL Masterspec Oct 2026 4222WH ITI NZ WEATHERTEX HORIZONTAL WEATHERBOARD | Page 98 of 213 2 PRODUCTS
- 2.1 WEATHERTEX PRIMELOK WEATHERBOARDS Weathertex Primelok weatherboards comply with AS/NZS 1859.4 for exterior hardboard and tested
- Weathertex Primelok weatherboards are 168mm or 197mm wide x 9.5mm thick x 3660mm long planks with a pre-primed finish. Planks incorporate a Primelok PVC Aligning Spline at the rear to
- For Weathertex pre-primed weatherboards with concealed or semi-concealed fixing, use specified hot dip galvanized nails in accordance with Fastening Tables in Weathertex New Zealand
- For Weathertex Selflok, pre-primed weatherboards with exposed traditional fix fastenings and for Weathertex Selflok, natural finish weatherboards use specified Grade 304 stainless steel nails for
- For Weathertex weatherboards use self-drilling, minimum 10g x 50mm countersunk Class 4 hot-dip galvanized screws for climatic zones B & C and suitably coated steel screws for Sea Spray Zone or
- paragraphs 9.1.7.5 - 9.1.7.7, for use in conjunction all Weathertex weatherboards. Available in 1830mm lengths.
- © CIL Masterspec Oct 2026 4222WH ITI NZ WEATHERTEX HORIZONTAL WEATHERBOARD | Page 99 of 213 3 EXECUTION
- For Primelok weatherboards, can substitute Weathertex Large Cavity Closer & Weathertex Starter Strip for a folded colour coated steel cavity closer strip 29mm wide, to requirements of NZBC
- Weathertex weatherboards except for Selflok Natural (unprimed) weatherboards. 2.11 TRIMTEC INTERNAL / EXTERNAL CORNER / STOP END TRIMS
- conjunction all Weathertex weatherboards, supplied in various profiles and lengths to suit selected weatherboards. Corner plugs used with traditional external corners are made from PVC. Refer to
- 2.12 WEATHERTEX STARTER STRIP - FOR PRIMELOK WEATHERBOARDS ONLY Weathertex Starter Strip, folded colour coated steel profile for use in conjunction with Weathertex
- Large Cavity Closer profile when using Primelok weatherboards. Available in 3000mm lengths. 2.13 FLASHINGS
- © CIL Masterspec Oct 2026 4222WH ITI NZ WEATHERTEX HORIZONTAL WEATHERBOARD | Page 100 of 213 Application - preparation / general
- suit weatherboard profile. Application - Weathertex Horizontal Weatherboards
- Installation of Weathertex weatherboards shall be in accordance to the Weathertex New Zealand Installation manual and BRANZ Appraisal 511 for Weathertex Direct Fixed Weatherboard Cladding
- Systems and BRANZ Appraisal 512 for Weathertex Cavity Fixed Weatherboard Cladding Systems. 3.11 GROUND CLEARANCE - SEAL BOTTOM EDGE & BACK FACE
- Ensure Weathertex weatherboards overhang bottom plate on a concrete slab by minimum 50mm. Ensure the bottom edge of Weathertex weatherboards are minimum 100mm clear of paved
- Reprime all cut edges of Weathertex pre-primed weatherboards with high quality tannin blocking exterior primer (water or solvent based). It is advisable to pre-paint a top coat at board ends
- If using countersunk screw fixings for pre-primed weatherboards, allow to prime screw holes after screwing. Once holes are filled, the filler should be sanded and area re-primed prior to painting.
- Weathertex weatherboards. It is recommended that expansion gaps be used for wall lengths greater than 6m to allow for thermal expansion / contraction of aluminium trims.
- © CIL Masterspec Oct 2026 4222WH ITI NZ WEATHERTEX HORIZONTAL WEATHERBOARD | Page 101 of 213 4 SELECTIONS
- Application - Weathertex Primelok Weatherboards 3.15 FIT PRIMELOK STARTER STRIP
- 3.16 FIXING - PRE-PRIMED PRIMELOK WEATHERBOARDS Install level, true to line and face. Commence at wall base, position the first boards so the Primelok
- board). For successive rows of weatherboards rest each plank on the previous row interlocking the Primlok spline with the angle top edge of the plank below, apply firm pressure to ensure interlocking
- 3.17 TRADITIONAL JOINER - PRIMELOK PRE-PRIMED WEATHERBOARDS Form joints midway between studs and stagger randomly throughout the wall. Between each stud,
- second row. Use Weathertex traditional jointer to suit profile / finish of selected weatherboard, fit joiner to the installed plank, rest the next plank on the plank below and slide into joiner. Joiners
- joining edge. To fit joiners to cut plank, trim back the spline on the back of the weatherboard to suit. Finishing
- Guide and to NZBC E2/AS1. Ensure minimum flashing cover to weatherboards is maintained. 3.19 PAINTING PRE-PRIMED WEATHERBOARDS
- Ensure Weathertex pre-primed weatherboards are painted with 60 days of installation. Refer to relevant painting section for details.
- © CIL Masterspec Oct 2026 4222WH ITI NZ WEATHERTEX HORIZONTAL WEATHERBOARD | Page 102 of 213 Materials
- 4.1 WEATHERTEX PRIMELOK - HORIZONTAL WEATHERBOARDS, PRE-PRIMED Location: Refer to plans
- 4.3 FIXINGS - FOR PRIMELOK WEATHERBOARD TO TIMBER FRAMING Location: refer to plans
- pre-primed Weathertex weatherboards - applied within 60 days of board installation.
- © CIL Masterspec Oct 2026 4222WH ITI NZ WEATHERTEX HORIZONTAL WEATHERBOARD | Page 103 of 213 1 GENERAL
- NZS 3617 Profiles of weatherboards fascia boards and flooring NZS 3631 New Zealand timber grading rules
- 2.7 TIMBER WEATHERBOARD Dressing grade to NZS 3631, to NZS 3617 for profile and treated to NZS 3602, table 2, reference
- 2.8 BOARD AND BATTEN In long lengths to profile detailed with species and grading to the requirements of NZS 3602 but with
- 2.9 FIBRE-CEMENT WEATHERBOARD Cellulose cement autoclaved sheets to NZS/AS 2908.2.
- Weatherboards: 14% at time of fixing Exterior joinery and trim: 14%
- 3.8 PRIME OR SEAL TIMBER WEATHERBOARDS AND TRIM Prime or seal all front and back faces, edges and end grain before fixing weatherboards and exterior
- 3.9 FIXINGS TO TIMBER CLADDINGS Stainless Steel Grooved nail
- 3.10 INSTALL TIMBER WEATHERBOARDS Install level, true to line and face, to NZBC E2/AS1: 9.4 Timber weatherboards. Refer to NZS 3604
- Weatherboard cladding - H3.1 (non-structural) 4.2 FIBRE CEMENT RIGID BACKING
- 4.3 TIMBER WEATHERBOARD Location: Refer to drawings
- Cladding: weatherboard Wall grille type/size: To suit cladding type and profile, provided by manufacturer or
- ITI NZ Weathertex Horizontal Weatherboard James Hardie® Soffits
Plans (PDF, 14.5MB)Project Specifications (PDF, 1.6MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.