← Board

14 Northview Terrace Kawarau Falls 9300

Queenstown Lakes · property 52290 · LOT 55 DP 497935 - 0.075700 Ha CT- 736556

Every consent eDocs lists on this property

Consent Description Applicant Status Status date
RM260770 Resource New Res Unit, With Associated Earthworks And Landscaping, Breaching Recession Place, Earthworks And Construction Noise Standards At 14 Northview Terrace, Kawarau Falls, Queenstown D & G Thornbury Decision Issued 13 Aug 2026
BC261546 Building New Threestorey Residential Dwelling With A Separate Flat And Attached Garage Rejected - Awaiting Info for Documentation Check
RM210357 Resource The Construction Of A Dwelling With Associated Earthworks, Noise, And Height Breaches At 14 Northview Terrace, Kawarau Falls, Queenstown J & S Mcneill & Bealey Trustee 13 Limited Decision Issued 23 Jun 2021
MN210357 J & S Mcneill & Bealey Trustee 13 Limited - The Construction Of A Dwelling With Associated Earthworks, Noise, And Height Breaches At 14 Northview Terrace, Kawarau Falls, Queenstown Unable to be monitored
PM190083 New Residential Dwelling (14 Northview Terrace) PIC/PIM Issued

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of BC261546 read 18 Nov 2026

Designer
Kerr Ritchie Ltd (Bronwen Kerr)
bronwen@kerrritchie.com
0273710441
Engineer
Chris Arlington (ENGCO)
chris@engco.co.nz
027 531 0760
Lodged by
Bronwen Kerr (architect)
bronwen@kerrritchie.com
0273710441
Applicant
Owner
diane@thornco.nz
0275609040
0272609040
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • 52.01 Details - Sliding Window - Shiplap 13 Nov 2026 52.02 Details - Window Fixed Ultraclad 13 Nov 2026
  • aluminium weatherboards. Colour Flaxpod (matt powdercoat).
  • Timber Weatherboards Cedar stained Wood X
  • Timber Shiplap Ultraclad Shadoline
  • Timber Shiplap Timber Shiplap
  • Alarm Timber Shiplap Ultraclad Shadoline
  • Ultraclad Shadoline vertical weatherboards. Rhom battens on RL AZ brackets.
  • C2 - Vertical timber shiplap Vertical shiplap profiled weatherboards
  • Shiplap Viblock
  • Shiplap FCL.2445
  • Shiplap ?
  • Timber Shiplap sump
  • Specified vertical shiplap aluminium cladding system
  • Shiplap Cladding
  • L3 Shiplap Grid Z C05
  • L2 Shiplap Grid Z C06
  • shiplap 480
  • Specified shiplap profiled weatherboards
  • Shiplap Typical XS C08
  • L3 Shiplap Internal Corner C13
  • Shiplap to Shadoline Ex. Corner C15
  • Shiplap 1 : 5
  • Window Shiplap Jamb W07
  • Win. Head - Shiplap W05
  • HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM SOFFIT CLADDING
  • VULCAN ULTRACLAD VERTICAL WEATHERBOARDS BRICK VENEER CLADDING
  • 4221HV Hermpac Vertical Weatherboard Cladding System 4239 Soffit Cladding
  • 4252VV Vulcan Ultraclad Vertical Weatherboards 4261 Brick Veneer Cladding
  • 4252VV Vulcan Ultraclad Vertical Weatherboards 4521PT Altus Thermal Aluminium Windows & Doors
  • 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM This section relates to the supply and fixing of Hermpac Vertical cladding:
  • Vertical Shiplap weatherboards Board and Batten weatherboards
  • Vertical Shiplap 'Vertibat' cavity batten systems 1.1 RELATED WORK
  • Refer to painting sections for finishes to weatherboard cladding. 1.2 ABBREVIATIONS AND DEFINITIONS
  • NZS 3617 Profiles of weatherboards, fascia boards and flooring JAS-ANZ CodeMark Certification CMNZ30036 - Hermpac VertiLine Vertical Shiplap Weatherboard
  • Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System installation Specifications Hermpac Product Technical Statement (PTS) – VertiLine Vertical Shiplap Weatherboard Cavity
  • Hermpac Product Installation Checklist – VertiLine Vertical Shiplap Weatherboard Cavity System (Jan 2023 V2)
  • Hermpac WR & Yellow Cedar cuts and characteristics BRANZ Appraisal 650 - Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System
  • © CIL Masterspec Nov 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 104 of 318 2 PRODUCTS
  • 5 years For installation of Hermpac vertical weatherboard cladding systems Provide this warranty on the installer/applicator standard form (if not available then use the
  • Hermpac vertical weatherboard cladding systems meet the requirements of the NZBC when used within the Conditions and Limitations of their Certificate CMNZ30036.
  • 2.1 WESTERN RED CEDAR Hermpac Canadian Western Red Cedar (Thuja plicata) supplied from sustainably managed forests
  • 2.2 VERTICAL SHIPLAP Weatherboards to Hermpac profiles, Lap and Rebate details to BRANZ BU 411 and general design
  • wood-based building components to achieve a 15-year durability performance. Weatherboards in lengths relevant to profile selection and application, with all unsound and open split knots excluded
  • Acceptable Solution is limited to the following types of weatherboards and their derivatives: Vertical Standard Shiplap and Hermpac Custom Profiles
  • © CIL Masterspec Nov 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 105 of 318 A selection of the above profiles are also available in Western Red Cedar and Yellow Cedar
  • finger-joint (CedarOne Evolve and CedarLine Evolve). CedarOne Evolve is quarter-sawn cut Cedar. CedarLine Evolve is primarily flat-sawn cut Cedar. Evolve profiles are available across most
  • Site applications to manufacturers specifications. All Hermpac weatherboards and mouldings must be coated all six sides prior to installation.
  • © CIL Masterspec Nov 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 106 of 318 3 EXECUTION
  • All Hermpac weatherboard cladding systems will arrive on site with a minimum of one coat factory finish. Additional coat/s will be required to achieve the desired look. Ensure site coating
  • applications are to coating manufacturers specifications. All Hermpac weatherboards and mouldings must be coated with a specified coating system on all bare surfaces and ends must be
  • framing, and NZBC E2/AS1, 9.4 Timber weatherboards, governing support for timber board cladding and Hermpac Installation Specifications.
  • © CIL Masterspec Nov 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 107 of 318 3.9 PENETRATIONS
  • relative to visible edge of board. For vertical shiplap boards, where possible the exposed lap should face away from the prevailing wind.
  • Install level, true to line and face, to NZBC E2/AS1: 9.4 Timber weatherboards. Double coat all cut ends before fixing. Provide one face fixing per weatherboard at each Vertibat cavity batten over
  • Hermpac Western Red Cedar, Yellow Cedar, DuraLarch™ or AshinDura™ weatherboards fixed with Stainless Steel or Silicon Bronze Hermpac Crown, Rose and Flat Head nails or Hermpac Starcap
  • screws and Kanda weatherboards fixed with Hermpac Starcap screws are limited to use in NZS 3604 Wind Zones up to and including Extra High when dwangs or structurally fixed Vertibat cavity
  • Hermpac Western Red Cedar weatherboards fixed with stainless steel jolt head nails are limited to use in NZS 3604 Wind Zones up to and including Medium when dwangs or structurally fixed Vertibat
  • Hermpac Yellow Cedar, DuraLarch™ and AshinDura™ weatherboards fixed with jolt head nails are limited to use in NZS 3604 Wind Zones up to and including Extra High when dwangs or structurally
  • 3.13 FIXING VERTICAL SHIPLAP WEATHERBOARDS Install level, true to line and face, to NZBC E2/AS1: 9.4 Timber weatherboards. Single face fix
  • weatherboards to every fixing point, clear of the adjacent lapped board. Fixing to be driven in with a slightly upward slope. Line fixings horizontally across the boards. Pilot drill all fixings slightly
  • Hermpac Construction Drawings for accurate weatherboard fixing information. Using a Hermpac specialty clinch nail, prior to the next row of Vertical Shiplap boards being fixed
  • clinch nail into the cavity batten so that the clinch head settles flush into the weatherboard's surface. The clinch nail head must not sit proud of the timber surface nor prevent the correct separation of
  • each adjacent row of boards. Do not pin laps or weatherboard faces. Kerr Ritchie Ltd Thornbury House 358359
  • © CIL Masterspec Nov 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 108 of 318 4 SELECTIONS
  • Kanda weatherboards must be fixed with Hermpac Starcap screws), correct placement of fixings, size, length and minimum penetration requirements, and for external and internal corner
  • Coated weatherboards laid over Mill Finish Grade 316 Stainless Steel: Sika: Wipe weatherboard surfaces with a clean rag. Using an abrasive pad, rub down Stainless
  • Steel in a single pass before cleaning with Sika Aktivator-205. Coat both weatherboards and Stainless Steel with Sika Primer 3N and apply a continuous 5mm bead of Sikaflex-11FC or Sikaflex
  • Soudal: Wipe weatherboard surfaces with a clean rag before wiping Stainless Steel only with Gorilla 696 Surface Activator, being careful not to coat any powder coated surfaces. Apply a minimum
  • 4.1 HERMPAC - VERTICAL SHIPLAP Location: refer drawings - Note: Weatherboards are profiled,
  • Species: Western Cedar Grade: Finger Joint
  • Profile type: Vertical Shiplap Surface finish: Band Sawn Face (BSF)
  • 4.2 WEATHERBOARD FASTENINGS - STAINLESS STEEL NAILS - WOOD OIL / OIL STAIN FINISH Nails: Crown Head
  • © CIL Masterspec Nov 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 109 of 318 4.4 HERMPAC CAVITY CLOSER/VERMIN-PROOFING
  • Material: Stainless Steel or PVC with fire-treated cedar 4.5 THIRD PARTY PROCESSOR - ZONE - FIREZONE VANGUARD FP
  • WRC Shiplap Boards: Timber delivered from Hermpac to Zone after profiling and then returned to Hermpac for coating
  • Cavity Battens: 18x45mm V8 cedar cavity battens to be impregnated with FireZone Vanguard FP if
  • © CIL Masterspec Nov 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 110 of 318 1 GENERAL
  • NZS 3617 Profiles of weatherboards, fascia boards and flooring NZS 4251.1 Solid plastering: Cement plasters for walls, ceilings and soffits
  • 2.1 SHIPLAP WEATHERBOARDS Shiplap timber weatherboard profile as per NZS 3617 or as detailed. In long lengths with species
  • 3.6 FIXING SHIPLAP WEATHERBOARDS AS SOFFIT CLADDING Adjust set-out to ensure there is a 2mm expansion gap between successive boards. Using full
  • Shiplap Weatherboard soffit cladding 4.1 SHIPLAP WEATHERBOARD - SOFFIT CLADDING
  • 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS This section relates to the supply and fixing of Vulcan Ultraclad® vertical inter-locking
  • weatherboards. It includes:
  • Aluminium weatherboards Timber battens
  • UltraClad® Cladding - Aluminium Weatherboards Brochure UltraClad® Profiled Metal Cladding - Specification
  • UltraClad® Aluminium Weatherboards - Installation Details BRANZ Appraisal 796 [2024]- Ultraclad® Vertical Weatherboard Cavity System
  • 140mm Teeboard Weatherboards. Manufacturer/supplier contact details
  • 25 years For durability of Ultraclad® aluminium weatherboards 20 years For film and colour integrity of powder coating
  • © CIL Masterspec Nov 2026 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS | Page 115 of 318 2 PRODUCTS
  • Vulcan Ultraclad® weatherboards are aluminium, meeting the requirements of NZBC C/AS1, 5.3 External cladding systems, and NZBC C/AS2, 5.5 External cladding systems, for non-combustible
  • 2.1 VULCAN ULTRACLAD VERTICAL WEATHERBOARDS Vulcan Ultraclad® weatherboards are manufactured from 6060-T5 grade extruded aluminium to
  • AS/NZS 1866. Weatherboard profiles are 15mm thick and available in a range of lengths, heights, profiles and finishes. Refer to SELECTIONS.
  • 2.2 ULTRACLAD WEATHERBOARD FIXINGS 8 gauge, grade 304 Stainless Steel screw fixings via locator clips to achieve min. 30mm embedment
  • © CIL Masterspec Nov 2026 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS | Page 116 of 318 3 EXECUTION
  • Powder coated extruded aluminium two piece jointer for jointing lengths of Ultraclad® weatherboard, available in 5m lengths.
  • © CIL Masterspec Nov 2026 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS | Page 117 of 318 Installation
  • Staple separation strip to face of cavity battens to isolate aluminium weatherboards from treated cavity batten.
  • 105mm max below the bottom plate. Mark precise level of weatherboard base around building and fix board starters through cavity battens to framing as per manufacturers details.
  • flashing into place once Ultraclad® weatherboards have been installed. Where possible allow for continuous length from the lowest point of cladding to the soffit, top of the wall or inter-storey joint.
  • Install vent (vermin barrier) strip as per manufacturers details, to base of weatherboards, horizontal open junctions and over openings (windows, meter boards, etc).
  • 3.12 ULTRACLAD WEATHERBOARD INSTALLATION Cut UltraClad® weatherboards to length allowing for a 1mm gap each end of board for expansion.
  • Install level, true to line and face. Lock first course of weatherboards into starter strip. Secure edge of board with locator clips screw fixed through the cavity battens to framing. Clip fixing to
  • courses of weatherboards into the channel of the previous board. 3.13 INTER-STOREY JUNCTIONS
  • Proprietary end cap profiles to be installed at ends of weatherboards at jambs and sills. Window and door joinery to cover cladding by 10mm min. Install inseal tape between joinery and cladding
  • Cut UltraClad® weatherboards and install over penetration with 5mm equal gap all round and install sealant in accordance manufacturer's instructions.
  • © CIL Masterspec Nov 2026 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS | Page 118 of 318 4 SELECTIONS
  • 4.3 VULCAN ULTRACLAD HORIZONTAL WEATHERBOARDS Location: refer 20 series
  • Type/brand: Vulcan Ultraclad® horizontal aluminium weatherboards Profile: Shadoline (UA 6975)
  • © CIL Masterspec Nov 2026 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS | Page 119 of 318 1 GENERAL
  • Installation - Rockwool Thermalrock® S, with weatherboard cladding, fibre cement sheet or similar lightweight cladding styles
  • Fire retardant system providing a Type A classification for solid western red cedar and thermally modified nordic pine timber claddings
  • FireZone™ Vanguard FP when used on minimum 16mm, western red cedar and thermally modified Nordic Pine has been tested to ISO 5660.1 to specific requirements of BPS, paragraph 8.4.1.3 or
  • Western Red Cedar and Thermally Modified Nordic Pine external claddings providing a Type A Classification to NZBC C/AS1, 5.3 External cladding systems, and NZBC C/AS2, 5.5 External
  • Location: to western cedar vertival weatherboard cladding and timber battens
  • Substrate: Solid Timber Cladding. Refer to ~ for details Species: Hermpac western cedar
  • Cladding: Vertical shiplap weatherboards to soffits and vertical alum. cladding

Plans (PDF, 24.7MB)Project Specifications (PDF, 3.0MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.