| RM261009 Resource | Construct An External Stairwell That Encroaches Into An Internal And Road Boundary Setback At 93 Stalker Road, Lower Shotover, Queenstown | N Jones & J Utton | Decision Issued | 30 Sep 2026 |
| BC261412 Building | On Hold - Alteration To An Existing Dwelling - Proposed Second Floor Flat Addition | Application OnHold - Clock is Paused | ||
| BC170952 Building | 93 Stalker Road, Shotover Country - New Single Storey Four Bedroom Dwelling With Attached Double Garage | CCC Issued | 15 May 2018 |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of BC261412 read 18 Nov 2026
- Value of work
- $350k estimated on the application form, GST included
- Lodged by
- Not named on the application form
- Timber cladding
-
- JAMES HARDIE LINEA WEATHERBOARD 70 SERIES CLAY BRICK VENEER
- JAMES HARDIE LINEA WEATHERBOARD INSTALLED TO EXTERIOR. EXTENT 90mm INTERNAL TIMBER FRAMED WALL
- WITH JAMES HARDIE LINEA WEATHERBOARD INSTALLED TO EXTERIOR. EXTENT OF GENERAL 90x45mm EXTERNAL TIMBER FRAMING
- JAMES HARDIE LINEA WEATHERBOARD
- JAMES HARDIE LINEA WEATHERBOARD JAMES HARDIE LINEA (16mm) WEATHERBOARD
- JAMES HARDIE LINEA WEATHERBOARD 2,775
- JAMES HARDIE LINEA WEATHERBOARD 1 SIDE. UNDERLAYS
- JAMES HARDIE LINEA WEATHERBOARD 300
- JAMES HARDIE LINEA WEATHERBOARD 1 SIDE. GBCJ30 GIB FIRE RATED CEILING SYSTEM, 30/30/30
- JH LINEA WEATHERBOARDS - BARGE DETAIL 1:10
- 'SELECTED' LINEA WEATHERBOARD TO 45x20mm FIXED OVER JAMES HARDIE "H3.1" VERTICAL CAVITY BATTENS FIXED OVER
- JH LINEA WEATHERBOARDS - EAVE DETAIL 1:10
- JH LINEA W.BOARDS - PARALLEL APRON FLASHING DETAIL 1:10
- BRICK/LINEA - INTER-STOREY JUNCTION 1:10
- JH LINEA W.BOARD - INTER-STOREY JUNCTION 1:10
- 'SELECTED' LINEA WEATHERBOARD TO 45x20mm FIXED OVER JAMES HARDIE "H3.1" VERTICAL CAVITY BATTENS
- HARDIE LINEA WEATHERBOARD INSTALLED TO EXTERIOR. 13mm GIB ON RONDO STEEL BATTENS DIRECT FIXED @
- HARDIE LINEA WEATHERBOARD INSTALLED TO EXTERIOR. 140x35mm & 90x45mm "H1.2" SG8 TOP PLATES
- HARDIE LINEA WEATHERBOARD INSTALLED TO EXTERIOR. 'SELECTED' LINEA WEATHERBOARD TO 45x20mm FIXED
- HARDIE LINEA WEATHERBOARD INSTALLED TO EXTERIOR. EXISTING JAMES HARDIE LINEA WEATHERBOARD FIXED
- LINEA WEATHERBOARDS TO PROVIDE EXTERIOR FIRE RATING FOR TWO-WAY FRR 30/30/30 FIRE RATING
- HARDIE LINEA WEATHERBOARD INSTALLED TO EXTERIOR. UPVC VENT STRIP (MITRE AT CORNERS) FIXED
- JH LINEA W.BOARDS - EXTERNAL CORNER 1:5
- LINEA ALUMINIUM EXTERNAL SLIMLINE BOX CORNER
- WEATHERBOARD 15mm CLEARANCE MUST BE MAINTAINED
- LINEA BOARD - SILL DETAIL 1:5
- LINEA BOARD - JAMB DETAIL 1:5
- LINEA BOARD - HEAD DETAIL 1:5
- SELECTED WEATHERBOARD. JAMES HARDIE UPVC VENT STRIP OVER JAMES HARDIE
- HARDIE LINEA WEATHERBOARD INSTALLED TO EXTERIOR. EXTENT OF JHETGL30 (FRR 30/30/30) TWO WAY FIRE
- HARDIE LINEA WEATHERBOARD INSTALLED TO EXTERIOR. GENERAL NOTES FOR MATERIALS SECTION
- James Hardie Linea™ Weatherboard ..................................................................................65 External Window & Door Joinery ............................................................................................68
- CodeMark Certificate of Conformity - James Hardie Linea Weatherboard Direct Fixed and Cavity Cladding..................................................................................................................115
- Linea™ Weatherboard Cavity Fix Technical Specification .................................................115 BRANZ Appraisal No.767 - Pink® Batts® Skillion Roof Insulation ......................................115
- BRANZ Appraisal No.446 - Linea Weatherboard Direct Fixed Cladding ............................115 COLORSTEEL Maxam™ Product Information Sheet...........................................................115
- 3617:1979(NZS) Specification for profiles of weatherboards, fascia boards, and flooring
- - Cedar Clears (Western Red Cedar, Thuja plicata) Premier Services Limited JCO26005 Utton Issued for Tender/Consent
- 5.3 James Hardie Linea™ Weatherboard 5.3.1 Scope
- Supply and install Linea Weatherboard 150mm as a fibre-cement weatherboard cladding material to the walls identified on the drawings, complete with all accessories. The Linea Weatherboards are to
- the James Hardie Linea Weatherboard Technical Specification (check www.jameshardie.co.nz, or call 0800 808 868 for the latest edition), Linea BRANZ Appraisals, and other relevant product
- James Hardie Linea Weatherboard Linea-Weatherboard-Direct-Fix-Technical- Specification.pdf and Linea-Weatherboad-Cavity-Fix-Technical-Specification.pdf Cladding is CodeMark
- Framing shall be plumb and in true alignment, complete and suitable for the weatherboards, and maximum moisture content as per NZS 3602. Ensure that the framing is true in line with no
- necessary works have been completed eg. flashings etc that will enable the weatherboards and all accessories to be installed.
- water against the building, and that the ground will be remain clear of the weatherboards by at least 100mm at all times in accordance with E2/AS1.
- Flexible silicone sealant to be SIKA Silaflex MS. Use to seal the weatherboards and accessories in accordance with the sealant manufacturer’s recommendations and to James Hardie requirements.
- All installation work shall be carried out by an LBP, or supervised by an LBP, in accordance with Linea Weatherboards Technical Specification and other relevant product manufacturers' recommendations.
- breathing silica dust. Do not use any damaged or blemished weatherboards or accessories. 5.3.7 Installation
- Install the Linea Weatherboards through the flexible underlay or rigid air barrier to the framing in accordance with the Technical Specification and BRANZ Appraisal No.446, complete with all
- accessories eg. corner mouldings, cant strip, sealant, soakers, etc. Weatherboard end joints are to be formed off framing with a tongue & groove joint and sealant.
- Ensure that all cut edges of weatherboards are primed prior to installation with Dulux 1 Step Prep, Resene Quick Dry, or similar. Ensure that the bottom edge of the weatherboard overhangs below the
- Fix weatherboards and accessories with galvanised nails using the concealed nailing method in accordance with James Hardie requirements.
- Ensure that the Linea Weatherboards have been fixed correctly, that all vertical joints and accessories have been completed correctly, and that all penetrations have been taped correctly. Check that no
- damage has occurred to any installed weatherboard element or associated component, replace as necessary. Check that no dirt has been mounded up within 175mm of the weatherboards, and
- maintain the clearance. Ensure that the weatherboards are painted within 90 days of the sheet installation, complete with all accessories and flashings. Hand over a copy of the latest edition of the
- Linea Weatherboard Product Warranty to the client. Hand over a copy of the latest Linea Weatherboard Care and Maintenance Schedule to the client.
- extreme care to keep absorbent materials (e.g. cedar, sawn framing, decking, paving) completely clean during all adjacent painting work. Correction of any such disfigurement shall be to the
Plans (PDF, 13.0MB)Project Specifications (PDF, 0.5MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.