63 Totara Terrace Wanaka 9305
Queenstown Lakes · property 47370 · LOT 2 DP 495291 - 0.054300 Ha CT- 726506
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| RM261256 Resource | K Davis | Being Vetted | ||
| BC261475 Building | Construction Of A Two Storey Detached Dwelling With Attached Double Garage. | PIC/PIM Issued |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of BC261475 read 18 Nov 2026
- Value of work
- $1.2m estimated on the application form, GST included
- Designer
- Kent Roper
kent@adq.co.nz
0204 051 8494 - Engineer
- Matthew Cusiel
matt@engco.co.nz
021 405 230 - Licensed: Design
- Kent Roper
- Licensed: Foundations
- Matthew Cusiel
- Lodged by
- ADQ Partnership Ltd. (Kent Roper) (Architectural Designer)
kent@adq.co.nz
0204 051 8494 - Applicant
- Owner
kristin@handkproperty.co.nz
021 966 955
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- 14mm Oblique horizontal weatherboard (200) on 20mm cavity over Thermakraft Watergate Plus on
- weatherboard (200) on 20mm cavity over Thermakraft Watergate Plus on
- weatherboard (200mm) on 20mm cavity over 6mm JameHardie RABTM
- 14mm Oblique horizontal weatherboard (200) on 20mm cavity over Thermakraft
- JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING JAMES HARDIE® SOFFITS
- 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING This section relates to the supply and fixing of Oblique™ Weatherboard cladding.
- Oblique™ Weatherboard by James Hardie® Cavity Cladding System
- Oblique™ Weatherboard Horizontal Installation Technical Specification (March 2026) Oblique™ Weatherboard Vertical Installation Technical Specification (March 2026)
- Oblique™ Weatherboard Vertical Installation to Hardie™ 40mm Structural Horizontal Cavity Batten Technical Specification (March 2026)
- BRANZ Appraisal 1231 (2022) - Oblique™ Weatherboard (Horizontal) Cavity Cladding - amended 31 March 2026
- BRANZ Appraisal 1232 (2022) - Oblique™ Weatherboard (Vertical) Cavity Cladding - amended 31 March 2026
- 25 years For Oblique™ Weatherboard products (refer to James Hardie® product warranty)
- © CIL Masterspec Oct 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 55 of 200 2 PRODUCTS
- Oblique™ Weatherboard Care and Maintenance guide. Provide this information prior to practical completion.
- 1.9 OBLIQUE™ WEATHERBOARD INSTALLATION CHECKLIST Installer to complete, sign and provide a James Hardie® Installation Checklist.
- James Hardie® Oblique™ Weatherboard meets the requirements of the NZBC when used within the Conditions and Limitations of its Certificate of conformity CMNZ30147.
- James Hardie® Oblique™ Weatherboard cladding tested to AS/NZS 3837 and to specific requirements of C/AS1 or C/AS2 achieving Type A classification (peak heat release rate ≤ 100
- 2.1 OBLIQUE™ WEATHERBOARDS Oblique™ Weatherboards, rusticated profile, 14mm thick, available in 200mm or 300mm widths and
- © CIL Masterspec Oct 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 56 of 200 3 EXECUTION
- Aluminium moulding used beside window opening to end butt the Oblique™ Weatherboard. 2.6 HARDIE™ 14MM ALUMINIUM TRIMLINE JOINT FLASHING
- Oblique™ Weatherboards over cavity battens over flexible underlay. 2.12 FLEXIBLE SEALANT
- © CIL Masterspec Oct 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 57 of 200 4 SELECTIONS
- weatherboards are fixed. Application - particular installations
- 3.5 INSTALL CAVITY BATTENS - OBLIQUE™ HORIZONTAL WEATHERBOARDS Install 20mm minimum thick cavity battens to NZBC E2/AS1, 9.0 Wall claddings, where required.
- 3.7 INSTALL OBLIQUE™ WEATHERBOARDS - HORIZONTAL INSTALLATION Cut weatherboards to required lengths for vertical jointing. Prime site cut ends that are exposed
- prior to installation. Fit vertical jointers, internal and external corners and fix weatherboards as per Oblique™ Weatherboard Horizontal technical specifications.
- 4.1 JAMES HARDIE® OBLIQUE™ WEATHERBOARDS Location: Refer to archi
- Type/Brand: Oblique™ Weatherboards Thickness: 14mm
- © CIL Masterspec Oct 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 58 of 200 4.2 TIMBER CAVITY BATTEN - FOR HORIZONTAL INSTALLATION
- © CIL Masterspec Oct 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 59 of 200 1 GENERAL
- 4.3 RESENE NEW EXTERIOR LINEA™ BOARDS Surface Prep: Resene SIPDS No3 and Spec Sheet 3: 4A/1
Plans (PDF, 12.9MB)Project Specifications (PDF, 2.3MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.