688 Peninsula Road Kelvin Heights 9300
Queenstown Lakes · property 4597 · Lot 109 DP 11164 - 0.062500 Ha CT- OTA2/1089
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| BC261314 Building | Alteration To Existing Dwelling. Roofing To Be Replaced And Infilling Of External Deck Area. Subfloor To Be Closed In A New Rooms Added. Alterations To Interior Layout Of First Floor. New Bathroom In Lower Floor. Exterior Cladding To Be Replaced. | In Progress | ||
| RM250964 Resource | To Construct A Residential Unit Breaching Height, Building Length And Internal Setback At 688 Peninsula Road, Queenstown | J Leckie & Veritas (2017) Limited | Decision Issued | 14 Jul 2026 |
| MN250964 | J Leckie & Veritas (2017) Limited - To Construct A Residential Unit Breaching Height, Building Length And Internal Setback At 688 Peninsula Road, Queenstown | Awaiting Officer Review | ||
| BC140961 Building | Remove Existing Deck And Addition Of Laundry | CCC Issued | 9 Apr 2015 | |
| BC131145 Building | 1. Remove Existing Deck 2. Lounge Addition | CCC Issued | 30 Mar 2015 | |
| BC990149 Building | Fire Appliance | Withdrawn | ||
| BC950882 Building | Erect New Dwelling | CCC Issued | 29 Jan 2004 |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of BC261314 read 18 Nov 2026
- Value of work
- $1.8m estimated on the application form, GST included
- Designer
- Sam Vivian
sam@bespokearchitecture.co.nz
03 385 0803 - Licensed: Design
- Matthew Ryley
- Lodged by
- Bespoke Architecture (Agent)
sam@bespokearchitecture.co.nz
03 385 0803 - Applicant
- Owner
matsandjosh@gmail.com
022 182 4855
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- W02 - SELECTED TIMBER SHIPLAP CLADDING OVER CAVITY W03 - EXISTING MONOLITHIC PLASTER CLADDING RETAINED
- 10 VERTICAL SHIPLAP TIMBER WEATHERBOARDS ON 20mm CAVITY
- VERTICAL SHIPLAP TIMBER WEATHERBOARDS ON 20mm CAVITY
- WINDOW HEAD - SHIPLAP Scale 1:5
- WINDOW SILL - SHIPLAP Scale 1:5
- JSC-TMT® Vertical shiplap weatherboards JSC-TMT® Board and Batten weatherboards
- NZS 3617 Profiles of weatherboards, fascia boards and flooring NZS 3631 New Zealand timber grading rules
- BRANZ BU 411 Recommended Timber Cladding Profiles CodeMark™
- JSC VertiClad Vertical Shiplap Weatherboard Cladding Installation Guide v3.7 JSC VertiClad Vertical Shiplap Weatherboard Cladding Design Guide v1.1
- JSC VertiClad Vertical Shiplap Weatherboard System Technical Drawings JSC Verticlad System Installation Checklist
- JSC Board & Batten Weatherboard Cladding Installation Guide v3.7 JSC Board & Batten Weatherboard Cladding Design Guide v1.0
- JSC Board & Batten Weatherboard System Technical Drawings JSC Board & Batten System Installation Checklist
- JSC Exterior Weatherboard Maintenance Guide JSC Structural Cavity Batten Setout and Fixing Guide
- JSC 20mm Cavity Setout For Vertical Weatherboards JSC Coatings Exterior Wood Oil Range
- Weatherboard Cladding Installation guides. Ensure the relevant JSC Weatherboard Cladding System Installation Checklist has been signed off
- this site and building height; as required by NZS 3604. Refer to JSC Weatherboard Cladding Installation guides.
- 2.2 VERTICAL SHIPLAP WEATHERBOARDS Selected timber weatherboards machined to JSC-TMT® profiles, lap and rebate details to BRANZ
- To JSC-TMT® profiles as detailed. Refer to SELECTIONS and JSC Weatherboard Cladding System Technical Drawings.
- Weatherboard Cladding Installation Guides for fixing details. NOTE: Select appropriate nail size / length to achieve the minimum required embedment into the
- Used to retain hidden lap tongues of rebated weatherboard profiles such as vertical shiplap. Refer to JSC Weatherboard Cladding Installation Guides for fixing details.
- 2.12 JSC-TMT® WEATHERBOARD SYSTEM COATING REQUIREMENTS All JSC weatherboards including mouldings must be coated on all sides before installation and
- cavities and 9.4 Timber weatherboards. 3.6 SUBSTRATE
- Foundation and sub-floor framing and NZBC E2/AS1, 9.4 Timber weatherboards. Application - preparation/general
- of weatherboard profiles within a controlled environment delivering a full envelope seal and a premium finish. Additional coatings may need to be applied on site as per the coating
- All JSC uncoated thermally modified timber weatherboards must be coated with one coat of suitable stain to JSC specification on all four sides prior to installation.
- openings (windows, meters, etc.) to JSC Weatherboards Cladding Installation Guides. Fix 75mm upstand to framing one side and 10mm upstand to cladding the other. Length and width
- door frames and other penetrations through the cladding to JSC Weatherboards Cladding Installation Guides.
- from the wall underlay towards the back of weatherboards ensuring water is shed away from the framing. Install to JSC 20mm Cavity Setout For Vertical Weatherboards instructions.
- Application - weatherboards 3.13 SET-OUT
- Install to NZBC E2/AS1, 9.4 Timber weatherboards. Coat all cut edges before fixing with JSC specified oil/stain product. Pre-drill all fixings 1mm smaller than nail gauge to ensure a snug fit and
- Refer to JSC Weatherboards Cladding Installation Guides for fixing sizes and details. Bespoke Architecture 688 Peninsula Road 360342
- 3.15 FIXING JSC® VERTICAL SHIPLAP WEATHERBOARDS Install to JSC® VertiClad Vertical Shiplap Weatherboards Cladding Installation Guide.
- JSC TMT® Vertical Shiplap Weatherboards must be pre-drilled with a slight (0-2°) upward slope, 1mm smaller than the nail shank to reduce moisture entry. Single-fix each weatherboard at 35mm
- from the overlapping edge of the weatherboard. Refer to installation guide for minimum embedment of nails into the framing.
- Note: Where vertical weatherboards have an exposed bottom edge such as at the bottom plate, window head, inter storey junction, overhead soffit junction, etc., the bottom edge of the
- weatherboards to be cut with a 15° degree slope to form a drip edge. From the bottom edge, the back of the weatherboards to be coated up to 75-150mm prior to installation.
- All corners to be weatherproofed using corrosion resistant back flashing behind the weatherboards at all external corners to JSC VertiClad Vertical Shiplap Weatherboard Cladding Installation Guide.
- Fix windows to JSC Weatherboards Cladding Installation Guides. 3.17 FLASHING
- Fix to JSC Weatherboard Cladding Installation Guide. Material compatibility to NZBC E2/AS1, Table C.1.1.1B: Compatibility of materials in contact, and Table C.1.1.1C: Compatibility of materials
- Scribers are to be wet-sealed in place and fixed in accordance with JSC Weatherboard Cladding Installation Guide.
- James Hardie Axon™ Panel, face primed shiplap jointed panels, 9.0mm and 8.5mm thick, manufactured from cellulose fibre reinforced cement to AS/NZS 2908.2. Refer to SELECTIONS.
- Avoid distortion and contact with potentially damaging shiplap edges and surfaces. Do not drag panels across each other, or across other materials. Protect edges, corner and surface finish from
Processing RFI 1 - Plans Architectural (PDF, 17.4MB)Project Specification (PDF, 2.9MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.
From the documents of RM250964 read 19 Nov 2026
- Lodged by
- Not named on the application form
- Timber cladding
-
- -VERTICAL TIMBER SHIPLAP -PLASTER AND SUBSTRATE TO MATCH EXISTING
Updated plans 15/05/26- RENOVATION (PDF, 22.3MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.
- Not read
- no correspondence section in: Appendix A - Form 9