← Board

103 Arrowtown-lake Hayes Road Lake Hayes 9371

Queenstown Lakes · property 2732 · Lot 3 DP 11726 - 0.081200 Ha CT- OT3C/558

Every consent eDocs lists on this property

Consent Description Applicant Status Status date
RM260302 Resource Withdrawn S Green, J Walden & J Walden Withdrawn
BC261336 Building Alteration & Addition To Existing Dwelling, Including A New Internal Access Garage. Application Documentation Checked
SS190221 Signing And Sealing - C Lloyd, G Brinsley, J Brinsley & M Brinsley - Addition Of A Residential Flat That Will Be Located Within The Internal Boundary Setback At 103 Arrowtown-Lake Hayes Road, Wakatipu Basin Issued
RM190221 Resource Addition Of A Residential Flat That Will Be Located Within The Internal Boundary Setback At 103 Arrowtown-Lake Hayes Road, Wakatipu Basin C Lloyd, G Brinsley, J Brinsley & M Brinsley Decision Issued 5 Aug 2019
RM190002 Resource Enclose An Existing Car Port Into A Store Room That Will Be Located Within The 2M Internal Boundary Setback At 103 Arrowtown-Lake Hayes Road, Arrowtown C Lloyd, G Brinsley, J Brinsley & M Brinsley Decision Issued 19 Mar 2019
MN190221 C Lloyd, G Brinsley, J Brinsley & M Brinsley - Addition Of A Residential Flat That Will Be Located Within The Internal Boundary Setback At 103 Arrowtown-Lake Hayes Road, Wakatipu Basin Unable to be monitored
DB191325 Alter Lower Basement Area: Add To Floor Area To Include New Kitchen And Bathroom And Extending Living Area. Alter Ground Floor Plan To Include Extended Bedroom1 And New En-Suite And Wr. Alter Bed 2 By Removing Exist Wall - 103 Arrowtown-Lake Hayes Road Cancelled
BC191325 Building Alter Lower Basement Area: Add To Floor Area To Include New Kitchen And Bathroom And Extending Living Area. Alter Ground Floor Plan To Include Extended Bedroom1 And New En-Suite And Wr. Alter Bed 2 By Removing Exist Wall. Building To Be Used As A Single Household Unit. CCC Issued 26 Feb 2025
BC181823 Building Alteration To Existing Dwelling - Enclose Existing Carport (In Part) To For New Storage Area. Am181823.01: Installation Of Metro Wee Rad, Freestanding, Dry, Wood Burner. Removal Of Non-Load Bearing Wall Between Kitchen And Lounge. Alterations To Laundry, Wc And Form New Door To Hallway. Change Of Slab Detail To Enclosed Carport Store Area. 103 Arrowtown-Lake Hayes Road - CCC Issued 3 Sep 2021
BC040008 Building Connection To New Lake-Hayes Sewage Scheme CCC Issued 14 Jan 2005

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of BC261336 read 18 Nov 2026

Value of work
$1m estimated on the application form, GST included
Lodged by
Not named on the application form
james@threefoldarchitecture.co.nz
0273509943
Applicant
Owner
janewaldengreen@gmail.com
021468622
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • E.2.01 SHIPLAP VENEER SECTIONAL GARAGE DOOR, FLUSH FACE PANEL FINISH WITH ADJACENT CLADDING. NO REVEALS. AUTO
  • 40X40MM BANDSAWN FACE CEDAR BATTENS WITH 20MM GAP, FIXED OVER 40X40MM SHS SED STEEL FRAME. STAIN FINISH TO
  • TIMBER CLADDING RK TIMBERS SHIPLAP CLADDING SYSTEM, CHARTEK FINISHED
  • VERTICAL WESTERN RED CEDAR RK55 PROFILE (110MM COVER BOARDS - 6MM NEGATIVE) OVER 45X20MM H3.2 HORIZONTAL
  • PLANK WEATHERBOARD WALL CLADDING - EXISTING 7.5MM JAMES HARDIE, HARDIE PLANK WEATHERBOARD. 300MM
  • SHIPLAP TIMBER CEILING - REFER TO INTERIOR DESIGN DRAWINGS FOR FURTHER INFORMATION AND SPECIFICATION
  • 2. ALL SHIPLAP FITTED TO THE DOOR SHALL ALIGN WITH WALL CLADDING.
  • E.2.01 SHIPLAP FIXED TO 12MM H3 PLYWOOD ON CAVITY BATTENS AS REQUIRED TO
  • ALLOW FOR WEATHERBOARDS SHOWN DASHED TO BE INSTALLED AFTER
  • TIMBER CLADDING TO TIMBER SUBFLOOR SCALE 1:5
  • TIMBER CLADDING SLIDING DOOR SILL SCALE 1:5
  • TIMBER CLADDING WINDOW SILL SCALE 1:5
  • TIMBER CLADDING WINDOW HEAD SCALE 1:5
  • TIMBER CLADDING WINDOW JAMB SCALE 1:5
  • TIMBER CLADDING SLIDING DOOR HEAD SCALE 1:5
  • TIMBER CLADDING INTERNAL CORNER SCALE 1:5
  • TIMBER CLADDING EXTERNAL CORNER SCALE 1:5
  • SCREW FIXED 40MM CEDAR BATTENS TO 50X50X3MM MS ANGLE, PC FINISH.
  • SCREW FIXED 40MM MACROCARPA BATTENS TO 50X50X3MM MS ANGLE,
  • TIMBER CLADDING EXTERIOR SURFACE STACKER HEAD OVER WINDOW HEAD SCALE 1:5
  • TIMBER CLADDING EXTERIOR SURFACE STACKER SILL TO WALL SCALE 1:5
  • TIMBER CLADDING EXTERIOR SURFACE STACKER HEAD TO WALL SCALE 1:5
  • TIMBER CLADDING EXTERIOR SURFACE STACKER SILL SCALE 1:5
  • TIMBER CLADDING EXTERIOR SURFACE STACKER HEAD SCALE 1:5
  • TIMBER CLADDING EXTERIOR SURFACE STACKER JAMBS SCALE 1:5
  • TIMBER CLADDING EXTERIOR SURFACE STACKER TO WINDOW JAMB SCALE 1:5
  • TIMBER CLADDING EXTERIOR SURFACE STACKER OVER JAMB OVER WINDOW JAMB SCALE 1:5
  • NEW RAIN SCREEN 40MMX40MM CEDAR TIMBER BATTENS @ 60MM CRS
  • SCREW FIXED 40MM CEDAR BATTENS TO 50X6MM MS FLAT PLATE STRAP, PC FINISH.
  • TIMBER CLADDING PIPE PENETRATION
  • SHIPLAP ON CAVITY BATTENS, OVER RAB/ BUILDING WRAP ON FRAMING.
  • Rosenfeld Kidson & Co Cedarscreen Weatherboard Systems ...............................................................................84 External Window & Door Joinery ..................................................................................................................................90
  • 3617:1979(NZS) Specification for profiles of weatherboards, fascia boards, and flooring 3622:2004(NZS) Verification of timber properties
  • Check the condition of existing timber framing, flooring, weatherboards/cladding, timber facings and trim, etc., as access is available during the contract, and report any deterioration to the Architect/Designer. Any remedial works to be proceeded with will be directed
  • All exterior cornices, eaves and eaves soffit trim, weatherboard panels trim to adjacent materials, all bandsawn cedar. 7.4.11 Interior Finishing Trim
  • 8.3 Rosenfeld Kidson & Co Cedarscreen Weatherboard Systems 8.3.1 Scope
  • 8.3.1.1 Cedarscreen Vertical Shiplap Weatherboard - 20mm Cavity Supply and install the Rosenfeld Kidson Cedarscreen Vertical Shiplap Weatherboard 20mm Cavity System, as specified herein, to the
  • The Rosenfeld Kidson Cedarscreen Vertical Shiplap Weatherboard 20mm Cavity System is CodeMark assured: CodeMark Product Certificate No. CM70083, issued by Bureau Veritas Australia Pty Ltd.
  • No substitutions or deletions are permitted for the Rosenfeld Kidson Cedarscreen Vertical Shiplap Weatherboard 20mm Cavity System.
  • 8.3.2.1 Western Red Cedar, Premium Clears No 1 – Vertical Shiplap Weatherboard Rosenfeld Kidson Vertical Shiplap Weatherboard Premium Grade PC1 Clears shall be manufactured from sustainably sourced
  • Canadian Western Red Cedar (Thuja plicata). Producers carry SFI, CSA, FSC or PEFC Certifications. Western Red Cedar used above ground complies with New Zealand Building Code Clause B2 Durability, Performance Requirement
  • 8.3.3 Weatherboard Profile 8.3.3.1 RK55 Vertical Shiplap
  • RK55 Rosenfeld Kidson Vertical Shiplap Weatherboard: 110mm effective cover, 135mm wide x 18.5mm thick. Installed Location:
  • 8.3.4 Weatherboard Finish & Coating 8.3.4.1 Bandsawn Face - Dryden WoodOil Clear Finish - Western Red Cedar
  • Cedarscreen Western Red Cedar weatherboard profiles and timber mouldings shall be shall be manufactured with a Bandsawn Face (BSF) and supplied factory-coated with Dryden WoodOil applied to all faces and edges.
  • All site-cut ends, notches and holes in weatherboards and timber mouldings must be sealed with one coat of Dryden WoodOil Threefold Architecture Ltd. 103 Arrowtown - Lakes Hayes Road Alteration Issued for Consent
  • Following installation, Cedarscreen Western Red Cedar weatherboards and timber mouldings shall be coated with a finishing coat of Dryden WoodOil, applied to all exposed surfaces.
  • 8.3.5.1 Timber Cavity Battens, 20mm Cavity - Vertical Weatherboard Timber Cavity Battens (non-structural) to form a nominal 20mm deep drained cavity for vertical weatherboards.
  • Cedarscreen Weatherboard Cladding Manual(s) 8.3.7.2 RK33 Eaves Mould
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s) 8.3.7.3 RK41 Timber Moulding
  • Cedarscreen Weatherboard Cladding Manual(s). 8.3.7.4 RK42 External Timber Moulding
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s). 8.3.7.5 RK91 Boxed Corner Cover Board
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s) 8.3.7.6 RK92 Boxed Corner Cover Board
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s) 8.3.7.7 RK93 External Timber Moulding
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s). 8.3.7.8 RK94 External Timber Moulding
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s). 8.3.7.9 RK95 External Timber Moulding
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s). 8.3.7.10 RK97 External Timber Moulding
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s) 8.3.7.11 RKA900 External Timber Moulding
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s). 8.3.7.12 RKA901 Timber Moulding
  • Cedarscreen Weatherboard Cladding Manual(s). Threefold Architecture Ltd. 103 Arrowtown - Lakes Hayes Road Alteration Issued for Consent
  • barriers, and trims and any other related works are completed in accordance with the Cedarscreen Weatherboard Cladding System technical manuals and approved construction drawings.
  • Cedarscreen weatherboards. Coordinate with trades the locations of pipes, outlets, cables, meter boards and other fittings installed by others, and to install
  • Cedarscreen Weatherboard Cladding System as required. 8.3.9 Workmanship
  • required construction and installation techniques, in accordance with applicable Cedarscreen Weatherboard Cladding Manual(s) and to fully comply with all warranty requirements.
  • Store Cedarscreen weatherboards and accessories undercover, flat and true, clear of the ground by at least 100mm and supported on dry and clean timber in accordance with Rosenfeld Kidson & Co recommendations. Keep stored weatherboards and accessories dry
  • Do not use damaged or defective weatherboards or accessories. Should a problem be encountered with any Rosenfeld Kidson & Co product, immediately contact Rosenfeld Kidson & Co on 09 573 0503 (North Island) or 03 349 3316 (South Island). Do not continue
  • Handle weatherboards in accordance with the manufacturer's recommendations and in a manner that prevents damage and surface marking.
  • 8.3.11.1 Cavity Fix over Rigid Underlay - 20mm Cavity, Vertical Weatherboard Cedarscreen Shiplap Weatherboard Cladding - installed over bevelled and castellated Cavity Batten profiles with a Rigid Wall
  • Install Cedarscreen Weatherboard Cladding, complete with all system components and accessories required for proper installation and performance, in accordance with the appropriate Cedarscreen Cladding System Manual and as shown on the approved
  • Ensure that all site-cuts to weatherboards and timber mouldings are properly sealed with Dryden WoodOil accordance with WoodOil application requirements
  • All internal and external weatherboard corner junctions, inter-storey junctions, and weatherboard trim and accessories, shall be constructed and installed to the details shown on the drawings and Cedarscreen technical resources.
  • - The layout of the vertical shiplap weatherboards should be configured against the prevailing wind. - Establish an accurate measurement between the starting corner and finishing point, working out an even board set out taking into
  • - Jamb to head and sill junctions – ensure weatherboards are full width and continuous in length. - Ensure vertical weatherboards are continuous in length between inter storey heights (maximum height 2 storey).
  • - Check weatherboard length spread and use appropriately to suit each cladding face. 8.3.13 Fixing
  • 8.3.13.1 Fixing - Vertical Weatherboard, Cedarscreen Plug Nail, Silicon Bronze Fix Cedarscreen Weatherboards with Annular Grooved, Silicon Bronze RK Cedarscreen Plug Nails in accordance with Cedarscreen
  • All nail fixings shall be pre-drilled slightly smaller than the nail gauge. Do not brad weatherboards prior to face nailing. Single fix rusticated weatherboards at every fixing point, located 35-40mm up from the bottom or lapped edge of the weatherboard,
  • Ensure the weatherboards are set-out with an overlap of 25mm, with a 2mm expansion gap between boards at the overlap. Set rose head nails flush onto the board surface - not into or below the surface.
  • Check that the CedarscrenWeatherboard Cladding system has been correctly installed and fixed to the layout and details shown on the drawings and in accordance with the requirements of the applicable Cedarscreen Cladding Manual(s)
  • weatherboard cladding system is weathertight. Check for damage and defects - replace or repair as necessary to the required standard.

Plans (PDF, 19.1MB)Project Specifications (PDF, 1.0MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.