472 Speargrass Flat Road Speargrass Flat 9371
Queenstown Lakes · property 22974 · Lot 3 DP 381575 - 0.477600 Ha CT- 340681
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| BC260002 Building | Alteration To Existing Dwelling - Extension To Ground Floor Ensuite, Renovation To Upstairs Guest Room. New Construction Of 3 Bay Garage | Waiting for Further Information | ||
| RM180865 Resource | Building Alterations Of The Dwelling And An Addition To The Garage At 472 Speargrass Flat Road, Wakatipu Basin | R Neville & S Hoskin | Decision Issued | 10 Jul 2018 |
| MN180865 | R Neville & S Hoskin - Building Alterations Of The Dwelling And An Addition To The Garage At 472 Speargrass Flat Road, Wakatipu Basin | Complies | ||
| BC180704 Building | 472 Speargrass Flat Road - Single Storey Timber Frame Addition To Lounge Area, 2 Storey Dormer Addition To Existing Garage /Office With Stone Clad Wall With Outdoor Fore, Reclad Of Part Of The Existing House With Linea Weatherboard To Match Existing Garage / Office Cladding | CCC Issued | 23 Aug 2019 | |
| BC170645 Building | Heater: 472 Speargrass Flat Road, Qtn - Replace Woodburner | Decision made not to issue CCC at this time | 29 May 2017 | |
| RM081080 Resource | Additions To An Existing Cottage At Speargrass Flat Road, Wakatipu Basin | G & G Davis | Issued | 16 Sep 2008 |
| BC088069 Building | Alterations And Additions To Existing Dwelling | CCC Issued | 18 Jul 2012 | |
| BC055306 Building | Install Fireplace | CCC Issued | 21 Jul 2005 | |
| BC055270 Building | Connection To Public Sewer - Install Pump | Lapsed | 28 Jul 2005 | |
| RM020171 Resource | Extension & Conversion Of Existing Visitor Accommodation To Dwelling At Speargrass Flat Road, Wakatipu Basin | S Doubleday | Issued | 4 Apr 2002 |
| BC020137 Building | Formation Of Bedroom, Ensuite & Storage Area | CCC Issued | 16 Feb 2005 |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of BC260002 read 18 Nov 2026
- Value of work
- $300k estimated on the application form, GST included
- Lodged by
- Not named on the application form
- Timber cladding
-
- Linea weatherboard on 20mm timber cavity over
- Linea bevelback weatherboards fixed horizontally in selected colour
- Linea Weatherboard Cladding fixed horizontally on 20mm cavity batten
- Abodo thermally modified shiplap weatherboards fixed
- Linea bevelback weatherboards fixed
- upwards to the ridge. Extend no more than 20mm into gutters. Provide a minimum 150mm shiplap at side and end laps, ensuring all laps are formed to shed water to the exterior. The underlay must be
- care to keep absorbent materials (e.g. cedar, sawn framing, decking, paving) completely clean during all adjacent painting work. Correction of any such disfigurement shall be to the Architect/Designer's
Plans (PDF, 25.8MB)Project Specifications (PDF, 0.5MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.