St Pauls Court Queenstown 9300
Queenstown Lakes · property 21650 · Lot 16 DP 365562 - 0.065300 Ha CT- 270886
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| RM260776 Resource | S127 To Vary Consent Condition 1 Of Rm190910 To Amend Building Design And To Breach Height And Recession Plane At St Pauls Court, Queenstown | Y Pillai & C Allaka | Decision Issued | 17 Aug 2026 |
| BC261180 Building | Construction Of Three Storey Multi Unit Dwelling With Attached Garage | Waiting for Further Information | ||
| RM250468 Resource | To Carry Out A Residential Visitor Accommodation Activity From Two Residential Units For Up To 10 Guests, 365 Nights Per Year At St Pauls Court, Queenstown | Y Pillai & C Allaka | Withdrawn | |
| RM190910 Resource | Land Use Consent Is Sought To Erect Two Residential Units On Site That Will Exceed Permitted Height And Earthworks Restrictions, And Consequential Subdivision To Create Two Fee Simple Allotments At 11 St Lukes Lane, Queenstown | Y & A Chan | Decision Issued | 30 Apr 2020 |
| MN190910 | Y & A Chan - Land Use Consent Is Sought To Erect Two Residential Units On Site That Will Exceed Permitted Height And Earthworks Restrictions, And Consequential Subdivision To Create Two Fee Simple Allotments At 11 St Lukes Lane, Queenstown | Complies | ||
| ET190910 | Y & A Chan - Application To Extend The Lapse Date Of Resource Consent Rm190910 By 5 Years At St Pauls Court, Queenstown | Decision Issued | 14 May 2024 |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of BC261180 read 18 Nov 2026
- Value of work
- $4m estimated on the application form, GST included
- Designer
- Leigh Garner
leigh@originarch.com
02102317680 - Engineer
- James Knight
james@constructure.co.nz
09 320 5226 - Licensed: Design
- Leigh Garner BP134531
- Lodged by
- Leigh Garner (Architectural Designer)
leigh@originarch.com
02102317680 - Applicant
- Owner
yogesh.kg@gmail.com
02102317680
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- JSC Verticlad Timber weatherboard , to comply with E2/AS1 Vulcan Ultraclad to comply with E2/AS1
- EXTERIOR CLADDING: VERTICAL TIMBER WEATHERBOARDS (JSC VERTICLAD TMT) CAVITY: 45mm HORIZONTAL CASTELLATED BATTENS.
- W03 TIMBER FRAME - TIMBER CLADDING EXTERIOR CLADDING: JSC VERTICLAD - TMT AMBA
- WEATHERBOARDS (PINE) H3.1 - PAINT FINISH NOTE:
- EXTERIOR CLADDING: VERTICAL TIMBER WEATHERBOARDS (JSC VERTICLAD TMT)
- WEATHERBOARDS 20 SERIES BLOCKWORK
- WEATHERBOARDS JSC-H 45mm HORIZONTAL
- WEATHERBOARDS JSC ALUMINIUM CORNER
- VULCAN ULTRACLAD VERTICAL WEATHERBOARDS DIMOND PROFILED METAL ROOFING
- 4252VV Vulcan Ultraclad Vertical Weatherboards 4311D Dimond Profiled Metal Roofing
- JSC-TMT® Vertical shiplap weatherboards JSC-TMT® Board and Batten weatherboards
- NZS 3617 Profiles of weatherboards, fascia boards and flooring NZS 3631 New Zealand timber grading rules
- BRANZ BU 411 Recommended Timber Cladding Profiles CodeMark™
- JSC VertiClad Vertical Shiplap Weatherboard Cladding Installation Guide v3.7 JSC VertiClad Vertical Shiplap Weatherboard Cladding Design Guide v1.1
- JSC VertiClad Vertical Shiplap Weatherboard System Technical Drawings JSC Verticlad System Installation Checklist
- JSC Board & Batten Weatherboard Cladding Installation Guide v3.7 JSC Board & Batten Weatherboard Cladding Design Guide v1.0
- JSC Board & Batten Weatherboard System Technical Drawings JSC Board & Batten System Installation Checklist
- JSC Exterior Weatherboard Maintenance Guide Leigh Garner Architectural Design 11 St Pauls Court, New Dwellings 357604
- JSC 20mm Cavity Setout For Vertical Weatherboards JSC Coatings Exterior Wood Oil Range
- Weatherboard Cladding Installation guides. Ensure the relevant JSC Weatherboard Cladding System Installation Checklist has been signed off
- this site and building height; as required by NZS 3604. Refer to JSC Weatherboard Cladding Installation guides.
- 2.2 VERTICAL SHIPLAP WEATHERBOARDS Selected timber weatherboards machined to JSC-TMT® profiles, lap and rebate details to BRANZ
- To JSC-TMT® profiles as detailed. Refer to SELECTIONS and JSC Weatherboard Cladding System Technical Drawings.
- Weatherboard Cladding Installation Guides for fixing details. NOTE: Select appropriate nail size / length to achieve the minimum required embedment into the
- Used to retain hidden lap tongues of rebated weatherboard profiles such as vertical shiplap. Refer to JSC Weatherboard Cladding Installation Guides for fixing details.
- 2.12 JSC-TMT® WEATHERBOARD SYSTEM COATING REQUIREMENTS All JSC weatherboards including mouldings must be coated on all sides before installation and
- cavities and 9.4 Timber weatherboards. 3.6 SUBSTRATE
- Foundation and sub-floor framing and NZBC E2/AS1, 9.4 Timber weatherboards. Application - preparation/general
- of weatherboard profiles within a controlled environment delivering a full envelope seal and a premium finish. Additional coatings may need to be applied on site as per the coating
- All JSC uncoated thermally modified timber weatherboards must be coated with one coat of suitable stain to JSC specification on all four sides prior to installation.
- openings (windows, meters, etc.) to JSC Weatherboards Cladding Installation Guides. Fix 75mm upstand to framing one side and 10mm upstand to cladding the other. Length and width
- door frames and other penetrations through the cladding to JSC Weatherboards Cladding Installation Guides.
- from the wall underlay towards the back of weatherboards ensuring water is shed away from the framing. Install to JSC 20mm Cavity Setout For Vertical Weatherboards instructions.
- Application - weatherboards 3.13 SET-OUT
- Install to NZBC E2/AS1, 9.4 Timber weatherboards. Coat all cut edges before fixing with JSC specified oil/stain product. Pre-drill all fixings 1mm smaller than nail gauge to ensure a snug fit and
- Refer to JSC Weatherboards Cladding Installation Guides for fixing sizes and details. 3.15 FIXING JSC® VERTICAL SHIPLAP WEATHERBOARDS
- Install to JSC® VertiClad Vertical Shiplap Weatherboards Cladding Installation Guide. Using laser or mechanical devices, set out all nailing accurately in straight lines. Align weather
- JSC TMT® Vertical Shiplap Weatherboards must be pre-drilled with a slight (0-2°) upward slope, 1mm smaller than the nail shank to reduce moisture entry. Single-fix each weatherboard at 35mm
- from the overlapping edge of the weatherboard. Refer to installation guide for minimum embedment of nails into the framing.
- Note: Where vertical weatherboards have an exposed bottom edge such as at the bottom plate, window head, inter storey junction, overhead soffit junction, etc., the bottom edge of the
- weatherboards to be cut with a 15° degree slope to form a drip edge. From the bottom edge, the back of the weatherboards to be coated up to 75-150mm prior to installation.
- All corners to be weatherproofed using corrosion resistant back flashing behind the weatherboards at all external corners to JSC VertiClad Vertical Shiplap Weatherboard Cladding Installation Guide.
- Fix windows to JSC Weatherboards Cladding Installation Guides. 3.17 FLASHING
- Fix to JSC Weatherboard Cladding Installation Guide. Material compatibility to NZBC E2/AS1, Table C.1.1.1B: Compatibility of materials in contact, and Table C.1.1.1C: Compatibility of materials
- Scribers are to be wet-sealed in place and fixed in accordance with JSC Weatherboard Cladding Installation Guide.
- Materials - specific timber weatherboards 4.1 JSC-TMT® AMBA - VERTICAL SHIPLAP WEATHERBOARDS
- 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS This section relates to the supply and fixing of Vulcan Ultraclad® vertical inter-locking
- weatherboards. It includes:
- Aluminium weatherboards Timber battens
- UltraClad® Cladding - Aluminium Weatherboards Brochure UltraClad® Profiled Metal Cladding - Specification
- UltraClad® Aluminium Weatherboards - Installation Details BRANZ Appraisal 796 [2024]- Ultraclad® Vertical Weatherboard Cavity System
- 140mm Teeboard Weatherboards. Manufacturer/supplier contact details
- 25 years For durability of Ultraclad® aluminium weatherboards 20 years For film and colour integrity of powder coating
- © CIL Masterspec Oct 2026 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS | Page 55 of 169 2 PRODUCTS
- Vulcan Ultraclad® weatherboards are aluminium, meeting the requirements of NZBC C/AS1, 5.3 External cladding systems, and NZBC C/AS2, 5.5 External cladding systems, for non-combustible
- 2.1 VULCAN ULTRACLAD VERTICAL WEATHERBOARDS Vulcan Ultraclad® weatherboards are manufactured from 6060-T5 grade extruded aluminium to
- AS/NZS 1866. Weatherboard profiles are 15mm thick and available in a range of lengths, heights, profiles and finishes. Refer to SELECTIONS.
- 2.2 ULTRACLAD WEATHERBOARD FIXINGS 8 gauge, grade 304 Stainless Steel screw fixings via locator clips to achieve min. 30mm embedment
- © CIL Masterspec Oct 2026 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS | Page 56 of 169 3 EXECUTION
- Powder coated extruded aluminium two piece jointer for jointing lengths of Ultraclad® weatherboard, available in 5m lengths.
- © CIL Masterspec Oct 2026 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS | Page 57 of 169 Installation
- Staple separation strip to face of cavity battens to isolate aluminium weatherboards from treated cavity batten.
- 105mm max below the bottom plate. Mark precise level of weatherboard base around building and fix board starters through cavity battens to framing as per manufacturers details.
- flashing into place once Ultraclad® weatherboards have been installed. Where possible allow for continuous length from the lowest point of cladding to the soffit, top of the wall or inter-storey joint.
- Install vent (vermin barrier) strip as per manufacturers details, to base of weatherboards, horizontal open junctions and over openings (windows, meter boards, etc).
- 3.12 ULTRACLAD WEATHERBOARD INSTALLATION Cut UltraClad® weatherboards to length allowing for a 1mm gap each end of board for expansion.
- Install level, true to line and face. Lock first course of weatherboards into starter strip. Secure edge of board with locator clips screw fixed through the cavity battens to framing. Clip fixing to
- courses of weatherboards into the channel of the previous board. 3.13 INTER-STOREY JUNCTIONS
- Proprietary end cap profiles to be installed at ends of weatherboards at jambs and sills. Window and door joinery to cover cladding by 10mm min. Install inseal tape between joinery and cladding
- Cut UltraClad® weatherboards and install over penetration with 5mm equal gap all round and install sealant in accordance manufacturer's instructions.
- © CIL Masterspec Oct 2026 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS | Page 58 of 169 4 SELECTIONS
- 4.2 VULCAN ULTRACLAD VERTICAL WEATHERBOARDS Location: Refer Drawings
- Type/brand: Vulcan Ultraclad® horizontal aluminium weatherboards Profile: TBC
- © CIL Masterspec Oct 2026 4252VV VULCAN ULTRACLAD VERTICAL WEATHERBOARDS | Page 59 of 169 1 GENERAL