RM260517 Resource To Establish A Residential Unit Including Breaches Of Building Length And Indigenous Vegetation Clearance Standards, And The Variation And Potential Cancellation Of An Existing Consent Notice At 749 Aubrey Road, Wanaka S Bartrom, A Hackerschmied & Ardmore Trustee No 6 Limited Decision Issued 9 Jul 2026
DB260511 Construction Of Shed With A Habitable Space Within Development Contribution Not Required
BC261419 Building Construction Of Two Storey Dwelling With Attached Garage Granted
BC260511 Building Construction Of Shed With A Habitable Space Within. Boundary Retaining Wall And Sub-Soil Drainage To Soakpit Under Exemption Ex1649. Building Consent Issued 2 Jun 2026
RM250396 Resource To Construct An Accessory Building With Breach Road And Internal Boundary Setback With Associated Earthworks, Vary Consent Notice Conditions And Contaminated Land At 749 Aubrey Road, Albert Town, Wanaka S Bartrom & A Hackerschmied Decision Issued 30 Oct 2025
MN250396 S Bartrom & A Hackerschmied - To Construct An Accessory Building With Breach Road And Internal Boundary Setback With Associated Earthworks, Vary Consent Notice Conditions And Contaminated Land At 749 Aubrey Road, Albert Town, Wanaka Awaiting Monitoring Inspection
PM240042 To Build A 3.6M High Retaining Wall And 10Mx20m Shed/Garage With An Office/Studio PIC/PIM Issued
CC240066 Warbler Home Family Trust - Connection To Water Reticulation And Vehicle Crossing At 749 Aubrey Road, Wanaka Approved
RM180357 Resource To Change Condition 1 Of Rm170 To Amend The Location And Design Of An Approved Dwelling At 749 Aubrey Road, Wanaka Bailey Trustee Services Limited Decision Issued 3 Apr 2018
MN180357 Bailey Trustee Services Limited - To Change Condition 1 Of Rm170 To Amend The Location And Design Of An Approved Dwelling At 749 Aubrey Road, Wanaka Unable to be monitored
BC180409 Building 749 Aubrey Road, Wanaka - New Dwelling And Carport Lapsed 6 Jun 2018
RM170746 Resource New Dwelling And Water Tanks At 749 Aubrey Road, Wanaka R Macdonald & Bailey Trustee Services Limited Decision Issued 4 Oct 2017
MN170746 R Macdonald & Bailey Trustee Services Limited - New Dwelling And Water Tanks At 749 Aubrey Rd, Wanaka Monitoring Not Required
RM150884 Resource R Macdonald & Bailey Trustee Services Ltd - Land Use Consent To Construct A Residential Unit Being A Garage/Office Containing A Kitchenette, Two Sheds (Retrospective) That Breach Minimum Setback, Undertake Associated Landscaping And Earthworks And To Vary Condition 6 And Cancel Conditions 1, 3 And 4 Of Consent Notice 6674069.3 At 749 Aubrey Road, Wanaka Withdrawn Withdrawn
SS030339 Signing & Sealing - Warbler Home Family Trust - S243e Easement Cancellation - Subdivide Property Into 8 Allotments At Anderson Road, Wanaka, New Dp 355535 Issued

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of RM260517 read 19 Nov 2026

Lodged by
Nicole Malpass
nicole@ipsolutions.nz
02108060084
Applicant
S Bartrom, A Hackerschmied & Ardmore Trustee No 6 Limited
info@freeflowplumbing.co.nz
022 3188 994
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • brick veneer, and cedar weatherboards, with matching roofing and dark-toned joinery. The material palette is recessive and consistent with the natural environment, Consent

AEE (PDF, 7.7MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.

From the documents of BC261419 read 18 Nov 2026

Licensed: Design
Dylan Thomson
Licensed: Carpentry
MATT SMITH
Lodged by
Not named on the application form
dylan@southerndraught.co.nz
0276004838
Applicant
Owner
info@freeflowplumbing.co.nz
02108327363
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • Shiplap sarking to match weatherboard profile
  • Wall cladding: Hermpac HP55 Cedar shiplap weatherboard on 40mm structural castellated
  • WC VB HP55 shiplap weather board on 40mm H3.1 structural castellated cavity battens
  • S1 HP53 shiplap sarking on 70x35 SG8 soffit battens fixed to underside of trusses with 2/75x3.06mm nails at each intersection. S2 HP53 shiplap sarking on 90x45 SG8 H1.2 soffit battens (on edge) @ 600mm crs max fixed to underside of each truss with 12Gx150mm
  • WC VB HP55 shiplap weather board on 40mm H3.1 structural castellated cavity battens @ 480mm crs max. t: 027 600 4838 w: southerndraught.co.nz e: dylan@southerndraught.co.nz
  • WC VB HP55 shiplap weather board on 40mm H3.1 structural castellated cavity battens @ 480mm crs max. A
  • WC VB HP55 shiplap weather board on 40mm H3.1 structural castellated cavity battens @ 480mm crs max. t: 027 600 4838 w: southerndraught.co.nz
  • Hermpac HP55 Cedar shiplap weatherboard RAB IBS Rigid RAP with 15mm
  • Base of weatherboard cladding Scale 1:5 @ A3
  • Shiplap barge board Confirm all Nuralite details are accurate
  • Shiplap sarking on 70x35 SG8 H1.2 soffit battens @ 600mm crs
  • Shiplap weatherboard beyond Eave at dining room alcove
  • Shiplap sarking on 90x45 SG8 H1.2 soffit battens (on edge) @ 600mm crs
  • Shiplap sarking on 70x35 SG8 H1.2 soffit battens @ 600mm crs fixed to underside of
  • Hermpac HP55 Cedar shiplap weatherboard
  • Shiplap barge board H3 stair sub framing below
  • Shiplap weatherboard cladding 45mm H3.2 structural cavity battens @
  • Hermpac Weatherboard Cladding Systems...........................................................84 DYNEXbuild DynaFlash Universal Back Flashings................................................88
  • CODEMARK CMNZ30036 Vertical Shiplap .........................................................123 Escea install .........................................................................................................123
  • 3617:1979(NZS) Specification for profiles of weatherboards, fascia boards, and flooring
  • 5.4 Hermpac Weatherboard Cladding Systems 5.4.1 Scope
  • Supply and install the Hermpac Pacific Limited Weatherboard System, as specified herein, to the walls identified on the drawings, complete with all accessories and trim. For the purpose
  • 5.4.2 Vertical Weatherboard Vertical Shiplap Weatherboard
  • Supply and install the Hermpac Vertical Shiplap Weatherboard Cavity System, as specified herein, to the walls identified on the drawings, complete with all accessories and trim. All
  • The Hermpac Vertical Shiplap Weatherboard Cavity System is CodeMark assured. No substitutions or deletions are permitted for the Hermpac Vertical Shiplap Weatherboard
  • Western Red Cedar Weatherboard Profile ~as identified on the accompanying drawings
  • Hermpac Eave Mouldings - Shiplap Weatherboard Hermpac Vertical Shiplap Weatherboard Eave Moulding - Selected to suit the details shown
  • on the drawings. Nail fixings matched with the selected weatherboard fixing. Unless specified otherwise on the drawings, timber species, grade and surface finish to match weatherboards.
  • Hermpac vertical weatherboards. Vertibat V5 - 45 x 45mm thick, and Vertibat V6 - 70mm x 45mm thick, bevelled and castellated timber cavity battens; incorporating 20mm wide x 5mm
  • installed by others, and to install Hermpac Weatherboard Cladding System as required. 5.4.7 Workmanship
  • Building Work (RBW) memorandum and the associated Hermpac Weatherboard Cladding System, Product Installation Check List. Issue a copy of the RBW document to the Building
  • referenced and followed when installing Hermpac weatherboards. 5.4.8 Delivery & Handling
  • Store weatherboards and accessories undercover, flat and true, clear of the ground by at least 150mm and supported on dry and clean timber bearers at maximum 900mm centres in
  • accordance with Hermpac recommendations. Keep stored weatherboards and accessories dry and protected from damage and contamination, and free from bending or excessive
  • Do not use damaged or defective weatherboards or accessories. Dock any oversized knots, unacceptable or unrequired grade characteristic, or damaged
  • areas of weatherboard. Do not install weatherboards during periods of wet weather. Double seal all cut ends and fresh cut timber with selected exterior coating. Some grades of timber
  • Handle weatherboards in accordance with the manufacturer's recommendations and in a manner that prevents damage and surface marking.
  • Install the specified Hermpac Weatherboard Cladding System, complete with accessories, in accordance with the Hermpac installation requirements and technical literature and as shown
  • Weatherboard soaker and/or flashing material compatibility shall be in accordance with NZBC E2/AS1 2.2, and as shown on the drawings.
  • All internal and external weatherboard corner junctions, inter-storey junctions, and weatherboard trim and accessories, shall be constructed and installed to the details shown on
  • Always keep Hermpac weatherboard cladding lines consistent and true along walls and around corners.
  • Hermpac Vertical Shiplap Weatherboard Cavity-Fixed over a Rigid Wall Underlay on Timber framing
  • Hermpac Vertical Shiplap Weatherboards installed over a cavity drain (20mm/40mm/45mm) over a rigid wall underlay:
  • As specified and shown on the drawings, fix shiplap weatherboards to the timber framing through 20mm thick Vertibat cavity battens, or fix to Vertibat 40mm or 45mm thick cavity
  • Install full length weatherboards where possible. Where joints are unavoidable, scarf the weatherboards at 30º over a cavity batten line, and fix weatherboard ends, with the top board
  • Overlap, joint and fix cavity-installed Hermpac Shiplap Weatherboards in accordance with Hermpac installation requirements and as detailed on the drawings. NB: Ensure
  • weatherboard end-grains are double coated. 5.4.10 Fixing
  • Fix Hermpac Shiplap Weatherboards Fix Hermpac Shiplap Weatherboards with Grade 316 Stainless Steel finish as identified on
  • Ensure the weatherboards are set-out with an overlap of 32mm. Single fix weatherboards at every fixing point, with screws driven in a slight upward slope,
  • located 35-40mm from the bottom edge of the weatherboard, and no closer than 32mm from the end of the board.
  • Check that the specified Hermpac Weatherboard System has been correctly installed and fixed to the layout and details shown on the drawings; that all joints, associated trim and
  • Weatherboard Cladding System Product Installation Check List. Issue a copy of the RBW document to the Building Consent Authority and to the Main Contractor.
  • 1. CODEMARK CMNZ30036 Vertical Shiplap 2. Escea install
  • Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System 1. Certificate Holder Details
  • The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System consists of vertically fixed shiplap weatherboards, ventilated cavity battens, flashings and accessories.
  • The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System is an external vertically fixed wall cladding system for residential and light commercial type buildings where domestic construction techniques are used.
  • The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System if designed, used, installed and maintained in accordance with the conditions of this Certificate will comply with or contribute to compliance with the following performance provisions of the NZ Building Code:
  • 1. The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System is certified for buildings: a. not greater than 10 metre height, and
  • Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System This certificate is issued by an independent certification body accredited by JAS-ANZ, the product certification body appointed by the Chief Executive of the Ministry of Business,
  • i. up to and including Extra High; for oil or stain finished Western Red Cedar, Yellow Cedar or Kanda, or with paint finished AshinDura, and
  • are at maximum 400mm centres) for paint finished Western Red Cedar, or d. constructed with timber framing subject to specific engineering design up to a maximum design differential ultimate limit state
  • oil or stain finished Western Red Cedar, Yellow Cedar or Kanda. 2. The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System shall be designed, used, installed and maintained in accordance with:
  • a. the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System Installation Specifications, May 2023 V3 including: i. the Hermpac standard construction drawings applicable (refer sections 9 & 11 of this certificate), and
  • 3. The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System shall be only installed vertically on vertical, flat surfaces. 4. Only aluminium window and door joinery meeting the requirements of NZS 4211:2008 (including Amendment1) for the relevant Wind
  • Shiplap Weatherboard Cavity System. 5. The designer shall provide a signed Declaration for submission with the building consent application that the use of this product in the
  • 6. The installer shall supply a signed Product Installation Checklist Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System (January 2023 V2) for consideration for issuing a Code Compliance Certificate (CCC).
  • 1. Herman Pacific Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System Installation Specifications
  • 2. Herman Pacific VertiLine Vertical Shiplap Weatherboard 18-20mm Cavity System – Construction Drawings -
  • 3. Herman Pacific VertiLine Vertical Shiplap Weatherboard 40-45mm Cavity System – Construction Drawings
  • 4. Herman Pacific VertiLine Vertical Shiplap Weatherboard Cavity System Random Width and Depth– Construction Drawings
  • 5. Herman Pacific Product Installation Checklist – Hermpac Accoya VertiLine Vertical Shiplap Weatherboard Cavity System_Checklist
  • 6. BRANZ Hermpac Vertiline Vertical Shiplap Weatherboard Cavity System – BRANZ Appraisal No. 650 (2020)
  • Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System – BRANZ Appraisal No. 650 (2020)
  • 8. BRANZ HERMPAC Cedar Horizontal Cavity Battens – BRANZ Appraisal 1189 (2021)
  • 9. BRANZ Structures Test Report - HERMPAC Weatherboard Connections 5 March 2021 10. SCION Durability and Potential End-uses of some Timber Species
  • Shiplap Weatherboard 10 May 2013
  • the VertiLine Vertical Shiplap Weatherboard Cavity System 22 May 2020
  • 13. Herman Pacific Yellow Cedar – Technical Data Sheet 2021 14. Herman Pacific Kanda – Technical Data Sheet 2021
  • 16. Herman Pacific Hermpac Weatherboard Cladding Cavity Systems – SDS Index 20-May-2020 17. Henkel Adhesives Safety Data Sheet – Loctite HB S039 Purbond November 2015
  • • The system consists of vertically fixed shiplap weatherboards, proprietary cavity battens, flashings and accessories. • The Hermpac VertiLine Vertical Shiplap Weatherboards are manufactured from Western Red Cedar. Selected Weatherboards are also
  • manufactured from Yellow Cedar, Kanda and AshinDura. Western Red Cedar, Yellow Cedar and Kanda weatherboards are supplied either raw, with one coat of machine applied premium penetrating exterior grade oil stain to Hermpac specifications or, with a machine applied
  • primer coat and one machine applied undercoat of exterior grade paint to Hermpac specifications. AshinDura weatherboards are treated to H3.1 and are only available with a machine applied primer coat and one machine applied coat of exterior grade paint to Hermpac
  • o VertiLine Vertical Shiplap Weatherboard 18-20mm Cavity System – Construction Drawings - Version 2 dated 01 January 2022; and
  • o VertiLine Vertical Shiplap Weatherboard 40-45mm Cavity System – Construction Drawings - Version 2 dated 01 January 2022; and
  • o VertiLine Vertical Shiplap Weatherboard Cavity System Random Width and Depth– Construction Drawings - Version 2 dated 01 January 2022.

Plans (PDF, 27.9MB)Project Specification (PDF, 7.0MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.

From the documents of BC260511 read 19 Nov 2026

Value of work
$400k estimated on the application form, GST included
Designer
Sam Connell
sam@figureandground.co.nz
02040563884
Engineer
Alexander Loye
alex@tetrad.co.nz
033650726
Licensed: Design
Sam Connell
Lodged by
Figure and Ground (Designer)
ashleigh@figureandground.co.nz
033524333
Applicant
Owner
info@freeflowplumbing.co.nz
022 3188 994
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
Not mentioned in the documents read

From the documents of RM250396 read 19 Nov 2026

Lodged by
Not named on the application form
Timber cladding
Not mentioned in the documents read