15 Dip Road Jacks Point 9371
Queenstown Lakes · property 200440 · LOT 1141 DP 629299 - 0.044800 Ha CT- 1288586
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| BC261518 Building | Construction Of Single Storey Multiunit Dwelling With Attached Garage | Application Complete |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of BC261518 read 18 Nov 2026
- Value of work
- $800k estimated on the application form, GST included
- Designer
- Danny Kissell
danny@dkdesigns.co.nz
0211109163 - Licensed: Design
- Danny Kissell BP130990
- Lodged by
- Danny Kissell (Agent)
danny@dkdesigns.co.nz
0211109163 - Applicant
- Owner
joshuascott1202@gmail.com
0277760236
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- A05 CEDAR DETAILS A06 FIXTURE DETAILS
- VERT CEDAR SHIPLAP WEATHERBOARD
- VERT LINEA OBLIQUE WALL
- LINEA OBLIQUE WALL CLADDING SANDSTONE GREY 27% 52.72M² / 24% VERT CEDAR SHIPLAP WALL CLADDING WOOD X GLACIER PEAK NA 44.65M² / 20%
- VERT LINEA OBLIQUE WALL CLADDING HARDIE 20MM HORIZ CAVITY BATTENS
- VERT CEDAR WEATHERBOARD WALL CLADDING H3.1 20X40 VERTIBAT CAVITY BATTEN
- 10MM CEDAR SOFFIT LINING COLORSTEEL 5 RIB ROOF CLADDING
- VERT CEDAR WEATHERBOARD WALL CLADDING
- VERT CEDAR SHIPLAP WEATHERBOARD WALL CLADDING
- 18.5MM CEDAR SOFFIT LINING SOLID BLOCKING
- INTERNAL CORNER CEDAR/5 RIB USE TEMPORARY SPACER
- VERTICAL Cedar SHIPLAP WEATHERBOARD WALL
- Linea™ Oblique™
- Weatherboard fixed vertically
- Weatherboard fixed vertically, seal edges before fixing
- Weatherboard Cut the long edges of Linea™
- Weatherboard to butt into the aluminium
- Weatherboard James Hardie horizontal
- Weatherboard Proprietary tape or alternatively
- edge of Linea™ Oblique™
- Weatherboard fixed vertically Line of head flashing over
- Weatherboard to be sealed before
- Weatherboard fixed vertically Square of flexible
- Weatherboard over flashing tape, carefully cut to suit
- OBLIQUE/CEDAR Note: All site cut edges to be sealed 40
- Cedar shiplap Weatherboard
- Vertical Shiplap Weatherboard
- LINEA BOLIQUE Flexible flashing tape
- Selected CEDAR Vertical
- Weatherboard SELANT
- INTERNAL CORNER JUNCTION BETWEEN LINEA OBLQIUE & VERT SHIPLAP WIND | HIGH
- CEDAR DETAILS DATE | 03/11/26
- HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING
- 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM This section relates to the supply and fixing of Hermpac Vertical cladding:
- Vertical Shiplap weatherboards Board and Batten weatherboards
- Vertical Shiplap 'Vertibat' cavity batten systems 1.1 RELATED WORK
- Refer to painting sections for finishes to weatherboard cladding. 1.2 ABBREVIATIONS AND DEFINITIONS
- NZS 3617 Profiles of weatherboards, fascia boards and flooring JAS-ANZ CodeMark Certification CMNZ30036 - Hermpac VertiLine Vertical Shiplap Weatherboard
- Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System installation Specifications Hermpac Vertical Shiplap Weatherboard Direct Fix System Installation Specifications
- Hermpac Product Technical Statement (PTS) – VertiLine Vertical Shiplap Weatherboard Cavity System (July 2023)
- Hermpac Product Installation Checklist – VertiLine Vertical Shiplap Weatherboard Cavity System (Jan 2023 V2)
- Hermpac Board and Batten Weatherboard Cavity System Installation Specifications Hermpac Board and Batten Weatherboard Direct Fix System Installation Specifications
- Hermpac Product Technical Statement (PTS) – Board and Batten Weatherboard Cavity System (July 2023)
- Hermpac Product Installation Checklist – Board and Batten Weatherboard Cavity System (Jan 2023 V2)
- Hermpac WR & Yellow Cedar cuts and characteristics BRANZ Appraisal 650 - Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System
- © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 28 of 100 2 PRODUCTS
- 5 years For installation of Hermpac vertical weatherboard cladding systems Provide this warranty on the installer/applicator standard form (if not available then use the
- Hermpac vertical weatherboard cladding systems meet the requirements of the NZBC when used within the Conditions and Limitations of their Certificate CMNZ30036.
- 2.1 WESTERN RED CEDAR Hermpac Canadian Western Red Cedar (Thuja plicata) supplied from sustainably managed forests
- 2.2 VERTICAL SHIPLAP Weatherboards to Hermpac profiles, Lap and Rebate details to BRANZ BU 411 and general design
- wood-based building components to achieve a 15-year durability performance. Weatherboards in lengths relevant to profile selection and application, with all unsound and open split knots excluded
- Acceptable Solution is limited to the following types of weatherboards and their derivatives: Vertical Standard Shiplap and Hermpac Custom Profiles
- Vertical Standard Board and Batten and Hermpac Custom Profiles DK Designs Limited Lot 1141 Proposed 4+1 363516
- © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 29 of 100 A selection of the above profiles are also available in Western Red Cedar and Yellow Cedar
- finger-joint (CedarOne Evolve and CedarLine Evolve). CedarOne Evolve is quarter-sawn cut Cedar. CedarLine Evolve is primarily flat-sawn cut Cedar. Evolve profiles are available across most
- Western Red Cedar and Yellow Cedar. Profiles are machined with a “dressed” finish to the front face and the exposed corners are machined to paint quality - PQ (ie. rounded edges for paint
- © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 30 of 100 3 EXECUTION
- Site applications to manufacturers specifications. All Hermpac weatherboards and mouldings must be coated all six sides prior to installation.
- All Hermpac weatherboard cladding systems will arrive on site with a minimum of one coat factory finish. Additional coat/s will be required to achieve the desired look. Ensure site coating
- applications are to coating manufacturers specifications. All Hermpac weatherboards and mouldings must be coated with a specified coating system on all bare surfaces and ends must be
- framing, and NZBC E2/AS1, 9.4 Timber weatherboards, governing support for timber board cladding and Hermpac Installation Specifications.
- © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 31 of 100 Application - vertical cladding over cavity battens
- relative to visible edge of board. For vertical shiplap boards, where possible the exposed lap should face away from the prevailing wind.
- Install level, true to line and face, to NZBC E2/AS1: 9.4 Timber weatherboards. Double coat all cut ends before fixing. Provide one face fixing per weatherboard at each Vertibat cavity batten over
- Hermpac Western Red Cedar, Yellow Cedar or DuraLarch™ weatherboards fixed with Stainless Steel or Silicon Bronze Hermpac Crown, Rose and Flat Head nails or Hermpac Starcap screws and
- Kanda weatherboards fixed with Hermpac Starcap screws are limited to use in NZS 3604 Wind Zones up to and including Extra High when dwangs or structurally fixed Vertibat cavity battens are
- Hermpac Western Red Cedar weatherboards fixed with stainless steel jolt head nails are limited to use in NZS 3604 Wind Zones up to and including Medium when dwangs or structurally fixed Vertibat
- Hermpac Yellow Cedar and DuraLarch™ weatherboards fixed with jolt head nails are limited to use in NZS 3604 Wind Zones up to and including Extra High when dwangs or structurally fixed Vertibat
- 3.13 FIXING VERTICAL SHIPLAP WEATHERBOARDS Install level, true to line and face, to NZBC E2/AS1: 9.4 Timber weatherboards. Single face fix
- weatherboards to every fixing point, clear of the adjacent lapped board. Fixing to be driven in with a slightly upward slope. Line fixings horizontally across the boards. Pilot drill all fixings slightly
- Hermpac Construction Drawings for accurate weatherboard fixing information. DK Designs Limited Lot 1141 Proposed 4+1 363516
- © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 32 of 100 4 SELECTIONS
- Using a Hermpac specialty clinch nail, prior to the next row of Vertical Shiplap boards being fixed alongside (nogs or dwangs at maximum 480mm centres) and at a position hard up against but not
- clinch nail into the cavity batten so that the clinch head settles flush into the weatherboard's surface. The clinch nail head must not sit proud of the timber surface nor prevent the correct separation of
- each adjacent row of boards. Do not pin laps or weatherboard faces. Refer to Hermpac Construction Drawings and Installation Specification for suitable face fixings
- Kanda weatherboards must be fixed with Hermpac Starcap screws), correct placement of fixings, size, length and minimum penetration requirements, and for external and internal corner
- Coated weatherboards laid over Mill Finish Grade 316 Stainless Steel: Sika: Wipe weatherboard surfaces with a clean rag. Using an abrasive pad, rub down Stainless
- Steel in a single pass before cleaning with Sika Aktivator-205. Coat both weatherboards and Stainless Steel with Sika Primer 3N and apply a continuous 5mm bead of Sikaflex-11FC or Sikaflex
- Soudal: Wipe weatherboard surfaces with a clean rag before wiping Stainless Steel only with Gorilla 696 Surface Activator, being careful not to coat any powder coated surfaces. Apply a minimum
- 4.1 HERMPAC - VERTICAL SHIPLAP Location: See plans
- Species: Cedar Grade: HERMPAC Premium Clears No.1 (PC1)
- Profile type: Vertical Shiplap Thickness: 18.5mm
- 4.2 WEATHERBOARD FASTENINGS - SILICON BRONZE NAILS - WOOD OIL / OIL STAIN FINISH Nails: Crown Head
- © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 33 of 100 4.4 VERTIBAT PINE CAVITY BATTENS - NON STRUCTURALLY FIXED
- © CIL Masterspec Oct 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 34 of 100 1 GENERAL
- 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING This section relates to the supply and fixing of Oblique™ Weatherboard cladding.
- Oblique™ Weatherboard by James Hardie® Cavity Cladding System
- Oblique™ Weatherboard Horizontal Installation Technical Specification (March 2026) Oblique™ Weatherboard Vertical Installation Technical Specification (March 2026)
- Oblique™ Weatherboard Vertical Installation to Hardie™ 40mm Structural Horizontal Cavity Batten Technical Specification (March 2026)
- BRANZ Appraisal 1231 (2022) - Oblique™ Weatherboard (Horizontal) Cavity Cladding - amended 31 March 2026
- BRANZ Appraisal 1232 (2022) - Oblique™ Weatherboard (Vertical) Cavity Cladding - amended 31 March 2026
- 25 years For Oblique™ Weatherboard products (refer to James Hardie® product warranty)
- © CIL Masterspec Oct 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 35 of 100 2 PRODUCTS
- Oblique™ Weatherboard Care and Maintenance guide. Provide this information prior to practical completion.
- 1.10 OBLIQUE™ WEATHERBOARD INSTALLATION CHECKLIST Installer to complete, sign and provide a James Hardie® Installation Checklist.
- James Hardie® Oblique™ Weatherboard meets the requirements of the NZBC when used within the Conditions and Limitations of its Certificate of conformity CMNZ30147.
- James Hardie® Oblique™ Weatherboard cladding tested to AS/NZS 3837 and to specific requirements of C/AS1 or C/AS2 achieving Type A classification (peak heat release rate ≤ 100
- 2.1 OBLIQUE™ WEATHERBOARDS Oblique™ Weatherboards, rusticated profile, 14mm thick, available in 200mm or 300mm widths and
- Aluminium moulding used beside window opening to end butt the Oblique™ Weatherboard. DK Designs Limited Lot 1141 Proposed 4+1 363516
- © CIL Masterspec Oct 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 36 of 100 3 EXECUTION
- 2.9 WEATHERBOARD INTERNAL "W" CORNER Anodised aluminium extrusion to flash behind cladding at internal corners.
- Oblique™ Weatherboards over cavity battens over flexible underlay. 2.15 FLEXIBLE SEALANT
- weatherboards are fixed. DK Designs Limited Lot 1141 Proposed 4+1 363516
- © CIL Masterspec Oct 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 37 of 100 4 SELECTIONS
- 3.5 INSTALL CAVITY BATTENS - OBLIQUE™ VERTICAL WEATHERBOARDS Install 20mm thick Hardie™ Horizontal Cavity Battens. Fix horizontal cavity battens to wall framing
- 3.7 INSTALL OBLIQUE™ WEATHERBOARDS - VERTICAL INSTALLATION Cut weatherboards to required lengths. Prime site cut ends that are exposed prior to installation.
- Fit joint flashing, internal corners and external corners and fix weatherboards as per Oblique™ Weatherboard Vertical technical specifications.
- 4.1 JAMES HARDIE® OBLIQUE™ WEATHERBOARDS Location: See plans
- Type/Brand: Oblique™ Weatherboards Thickness: 14mm
- © CIL Masterspec Oct 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 38 of 100 4.5 HARDIE™ 14MM ALUMINIUM INTERNAL CORNER
- © CIL Masterspec Oct 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 39 of 100 1 GENERAL
Plans (PDF, 2.3MB)Project Specifications (PDF, 1.0MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.