← Board

30 Craigroy Crescent Wanaka 9305

Queenstown Lakes · property 193870 · LOT 57 DP 627497 - 0.060400 Ha CT- 1280745

Every consent eDocs lists on this property

Consent Description Applicant Status Status date
BC261420 Building Construction Of Single Storey Dwelling With Attached Garage PIC/PIM Issued

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of BC261420 read 18 Nov 2026

Value of work
$450k estimated on the application form, GST included
Designer
Tessa Silcock
tessa@tmsequestrian.com
027 443 2133
Builder
Benjamin King
ben.nz1@hotmail.com
021557276
Lodged by
Not named on the application form
Timber cladding
  • Weatherboard Soffit
  • Weatherboard D002
  • Weatherboard S
  • Vertical weatherboard wall cladding on 20x45 H1.2 cavity batten on 8mm IBS
  • Vertical Shiplap Weatherboard
  • Hermpac VertiLine Vertical Shiplap Installation Specifications. Selected Vertibat Cavity
  • Cavity Fix Vertical Shiplap Weatherboard System CMNZ30036
  • Hermpac Vertical Shiplap Installation Specifications. Selected Vertibat Cavity
  • 2.) Fix weatherboards either side of the scarf join. 3.) Crown head nail - 30mm minimum framing penetration.
  • - All weatherboard fixings pre-drilled maximum 1mm diameter smaller than the nail/screw gauge. - All Hermpac timber products, cut ends and edges to be precoated as per Installation Specifications.
  • - For non-hemmed corner flashings, ensure a minimum 75mm cover to weatherboards beyond the point where BRANZ Bulletin 411 compliant weatherboard lap or rebate combinations terminate at
  • - Prior to installation, refer to Hermpac Vertical Shiplap Technical Installation Specifications. .
  • Cavity Fix Vertical Shiplap Weatherboard System NOTES:
  • - Prior to installation, refer to Hermpac Vertical Shiplap Technical Installation Specifications. 1 Weatehrboard Internal Corner 1:5 2 Weatehrboard External Corner 1:5
  • 3 Bottom of Cladding - Weatherboard 1:5 4 Weatehrboard Scarf Join 1:5 8mm IBS RigidRAP
  • - Prior to installation, refer to Hermpac Vertical Shiplap Technical Installation Specifications. CMNZ30036
  • *Option for weatherboard to be finished hard against the back of fascia with good overlap provided weatherboard grooves are sealed. DRAWING
  • - Prior to installation, refer to Hermpac Vertical Shiplap Technical Installation Specifications. 1 : 2 @ A4 2022
  • 1 Weatherboard Sill 1:5 2 Weatehrboard Jamb 1:5 3 Weatherboard Head 1:5 4 Eave Detail 1:5
  • 2.2 TIMBER WEATHERBOARD As selected, or radiata pine to NZS 3631 for grading and to NZS 3602, table 2 Requirements for
  • 3.6 PRIME OR SEAL TIMBER WEATHERBOARDS Prime (for opaque finish) or seal (for clear finish) front and back faces, edges and end grain
  • (minimum 2 coats) before fixing weatherboards and exterior trim. 3.7 INSTALL TIMBER WEATHERBOARDS
  • Install level, true to line and face, to NZBC E2/AS1, 9.4 Timber weatherboards. 3.8 INSTALL EXTERIOR TIMBER FINISHINGS

Plans (PDF, 6.3MB)Project Specification (PDF, 0.6MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.