← Board

47 Stonehenge Road Wanaka 9382

Queenstown Lakes · property 191940 · LOT 23 DP 623502 - 0.068200 Ha CT- 1269235

Every consent eDocs lists on this property

Consent Description Applicant Status Status date
BC260358 Building Construct A New Single Storey Dwelling With Attached Garage CCC Processing Awaiting Further Information 29 Apr 2026

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of BC260358 read 18 Nov 2026

Designer
Threefold Architecture - Bryce Monk
bryce@threefoldarchitecture.co.nz
027 425 0644
Engineer
Engco - Patrick de la Mare
patrick@engco.co.nz
027 475 2775
Builder
Blair Coupe Building Ltd
blairbronnie@xtra.co.nz
021 689 465
Licensed: Design
Bryce Monk
Lodged by
Not named on the application form
martine@threefoldarchitecture.co.nz
027 252 9331
Applicant
Owner
blairbronnie@xtra.co.nz
021 689 465
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • SOFFITS - SHIPLAP ROSENFELD KIDSON WESTERN RED CEDAR STAINED SHIPLAP
  • TIMBER CLADDING ROSENFELD KIDSON SHIPLAP CLADDING SYSTEM, STAINED
  • VERTICAL WESTERN RED CEDAR RK55 PROFILE (110MM COVER BOARDS) OVER 20X45MM H3.2 HORIZONTAL CASTELLATED
  • CEDAR FACING BOARDS ADHESIVE F I X E D O V E R E . 1 . 1 5 C O R N E R
  • CEDAR FACE PANEL SCREW FIXED. E.2.05
  • CEDAR FACE PANEL SCREW FIXED. FLEXIBLE FLASHING TAPE OVER E.1.15
  • WEATHERBOARD CLADDING SYSTEM PENETRATIONS ARE THE RESPONSIBILITY OF
  • RUSTICATED W/B ON VERTICAL CAVITY BATTENS, OVER RAB/BUILDING WRAP ON
  • SHIPLAP WEATHERBOARD CLADDING SYSTEM TYPICAL VENT DUCT PENETRATION
  • New 3 bedroom, single story home with attached garage. Construction consistes of raft slab, and timber framing, clad with cedar vertical shiplap and kahu.
  • Rosenfeld Kidson & Co Cedarscreen Weatherboard Systems ...............................................................................57 Roofing..........................................................................................................................................................................62
  • 3617:1979(NZS) Specification for profiles of weatherboards, fascia boards, and flooring 3622:2004(NZS) Verification of timber properties
  • - Cedar Clears (Western Red Cedar, Thuja plicata) - Rimu - (NZ Red Pine)
  • 5.9 Rosenfeld Kidson & Co Cedarscreen Weatherboard Systems 5.9.1 Scope
  • 5.9.1.1 Cedarscreen Vertical Shiplap Weatherboard - 20mm Cavity Supply and install the Rosenfeld Kidson Cedarscreen Vertical Shiplap Weatherboard 20mm Cavity System, as specified herein, to the
  • The Rosenfeld Kidson Cedarscreen Vertical Shiplap Weatherboard 20mm Cavity System is CodeMark assured: CodeMark Product Certificate No. CM70083, issued by Bureau Veritas Australia Pty Ltd.
  • No substitutions or deletions are permitted for the Rosenfeld Kidson Cedarscreen Vertical Shiplap Weatherboard 20mm Cavity System.
  • 5.9.2.1 Western Red Cedar, Premium Clears No 1 – Vertical Shiplap Weatherboard Rosenfeld Kidson Vertical Shiplap Weatherboard Premium Grade PC1 Clears shall be manufactured from sustainably sourced
  • Canadian Western Red Cedar (Thuja plicata). Producers carry SFI, CSA, FSC or PEFC Certifications. Western Red Cedar used above ground complies with New Zealand Building Code Clause B2 Durability, Performance Requirement
  • 5.9.3 Weatherboard Profile 5.9.3.1 RK55 Vertical Shiplap
  • RK55 Rosenfeld Kidson Vertical Shiplap Weatherboard: 110mm effective cover, 135mm wide x 18.5mm thick. Installed Location:
  • 5.9.4 Weatherboard Finish & Coating 5.9.4.1 Bandsawn Face - Dryden WoodOil ColorTone Finish - Western Red Cedar
  • Cedarscreen Western Red Cedar weatherboard profiles and timber mouldings shall be manufactured with a Bandsawn Face (BSF) and supplied factory-coated with Dryden WoodOil and specified Dryden ColorTone tint applied to all faces and edges.
  • All site-cut ends, notches and holes in weatherboards and timber mouldings must be sealed with one coat of Dryden WoodOil Following installation, Cedarscreen Western Red Cedar weatherboards and timber mouldings shall be coated with a finishing coat of
  • 5.9.5.1 Timber Cavity Battens, 20mm Cavity - Vertical Weatherboard Timber Cavity Battens (non-structural) to form a nominal 20mm deep drained cavity for vertical weatherboards.
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s) 5.9.7.2 RK97 External Timber Moulding
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s) 5.9.8 Co-operation
  • barriers, and trims and any other related works are completed in accordance with the Cedarscreen Weatherboard Cladding System technical manuals and approved construction drawings.
  • Cedarscreen weatherboards. Coordinate with trades the locations of pipes, outlets, cables, meter boards and other fittings installed by others, and to install
  • Cedarscreen Weatherboard Cladding System as required. 5.9.9 Workmanship
  • required construction and installation techniques, in accordance with applicable Cedarscreen Weatherboard Cladding Manual(s) and to fully comply with all warranty requirements.
  • Store Cedarscreen weatherboards and accessories undercover, flat and true, clear of the ground by at least 100mm and supported on dry and clean timber in accordance with Rosenfeld Kidson & Co recommendations. Keep stored weatherboards and accessories dry
  • Do not use damaged or defective weatherboards or accessories. Should a problem be encountered with any Rosenfeld Kidson & Co product, immediately contact Rosenfeld Kidson & Co on 09 573 0503 (North Island) or 03 349 3316 (South Island). Do not continue
  • Handle weatherboards in accordance with the manufacturer's recommendations and in a manner that prevents damage and surface marking.
  • 5.9.11.1 Cavity Fix over Rigid Underlay - 20mm Cavity, Vertical Weatherboard Cedarscreen Shiplap Weatherboard Cladding - installed over bevelled and castellated Cavity Batten profiles with a Rigid Wall
  • Install Cedarscreen Weatherboard Cladding, complete with all system components and accessories required for proper installation and performance, in accordance with the appropriate Cedarscreen Cladding System Manual and as shown on the approved
  • Ensure that all site-cuts to weatherboards and timber mouldings are properly sealed with Dryden WoodOil accordance with WoodOil application requirements
  • All internal and external weatherboard corner junctions, inter-storey junctions, and weatherboard trim and accessories, shall be constructed and installed to the details shown on the drawings and Cedarscreen technical resources.
  • - The layout of the vertical shiplap weatherboards should be configured against the prevailing wind. - Establish an accurate measurement between the starting corner and finishing point, working out an even board set out taking into
  • - Jamb to head and sill junctions – ensure weatherboards are full width and continuous in length. - Ensure vertical weatherboards are continuous in length between inter storey heights (maximum height 2 storey).
  • - Check weatherboard length spread and use appropriately to suit each cladding face. 5.9.13 Fixing
  • 5.9.13.1 Fixing - Vertical Weatherboard, Stainless Steel Fix Cedarscreen Weatherboards with Rose Head, Annular Grooved, Grade 316 Stainless Steel Nails in accordance with Cedarscreen
  • All nail fixings shall be pre-drilled slightly smaller than the nail gauge. Do not brad weatherboards prior to face nailing. Single fix rusticated weatherboards at every fixing point, located 35-40mm up from the bottom or lapped edge of the weatherboard,
  • Ensure the weatherboards are set-out with an overlap of 25mm, with a 2mm expansion gap between boards at the overlap. Set rose head nails flush onto the board surface - not into or below the surface.
  • Check that the CedarscrenWeatherboard Cladding system has been correctly installed and fixed to the layout and details shown on the drawings and in accordance with the requirements of the applicable Cedarscreen Cladding Manual(s)
  • weatherboard cladding system is weathertight. Check for damage and defects - replace or repair as necessary to the required standard.
  • materials (e.g. cedar, sawn framing, decking, paving) completely clean during all adjacent painting work. Correction of any such disfigurement shall be to the Architect/Designer's approval.

Plans (PDF, 20.6MB)Project Specification (PDF, 1.4MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.