420 Mcdonnell Road Arrowtown 9371
Queenstown Lakes · property 190420 · LOT 1 DP 616852 - 118.600000 Ha CT- 1237891 LOT 2 DP 616852 - 22.225000 Ha CT- 1237891
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| RM261122 Resource | Consent Is Sought To Change Condition 1, Condition 28C And V Of Decision 1 Of Rm180497 To Clarify And Revise The Ffl For The Approved Residential Allotments At 420 Mcdonnell Road, Queenstown | Hogan Gully Farm Limited | S107G On Hold - Review of Draft Conditions | |
| RM261063 Resource | To Vary Condition 11(G) Of Decision 1. Subdivision Of Rm180497 (As Varied By, Rm221045, Rm240036, Rm240933, Rm241025, Rm250068, Rm250680, And Rm260823) (Appendix C) To Correct An Error, Improve Clarity, And Ensure That The Condition Can Be Complied With At 420 Mcdonnell Road, Queenstown | Hogan Gully Farm Limited | Formally Received | |
| RM260823 Resource | To Change Condition 20 Of Decision 3 Of Rm180497, To Enable Changes To The Operating Hours Of The Clubhouse At 420 Mcdonnell Road, Arrowtown | Hogan Gully Farm Limited | Decision Issued | 10 Sep 2026 |
| BC261495 Building | Stage 1 Of 2 Foundations, Subfloor Structure, And Drainage To Civil Connection For Future 10 Singlestorey Visitor Accommodation Buildings, | Application Complete | ||
| BC261341 Building | Stage 2 Of 3 - Construction Of Commercial Building - External Envelope (Walls & Roof) Only | Waiting for Further Information | ||
| BC251332 Building | Stage 1 Of 3 - Construction Of Commercial Building - Foundations, Basement Walls, Floor Slabs And Sub-Floor Drainage Only. Including Amendment 01 - Change To Precast Columns, Wider Precast Panels, Ramp To Basement And Retaining Walls, Confirmed Backfill Design, Revised Drainage. | Building Consent Issued | 4 Mar 2026 |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of RM261063 read 18 Nov 2026
- Lodged by
- Not named on the application form
- Timber cladding
- Not mentioned in the documents read
- Not read
- no application form (Form 9); no plans
From the documents of BC261341 read 18 Nov 2026
- Designer
- Richard Andrews- Patterson Associates
richard@pattersons.com
+64 9 303 4004 - Engineer
- Not named
peterh@holmesgroup.com
+64 27 4331057 - Lodged by
- Patterson Associates Ltd (The owner has authorised Pattersons (architects) to make this application on their behalf.)
richard@pattersons.com
09 303 4004 - Applicant
- Owner
shane.muir@trojanholdings.co.nz
021797784
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- This section relates to the supply and fixing of timber cladding: weatherboards
- shiplap board and batten
- NZS 3617 Profiles of weatherboards, fascia boards and flooring NZS 3631 New Zealand timber grading rules
- 2.4 WEATHERBOARDS Profile (unless detailed otherwise) to NZS 3617, species and grading to NZS 3602, NZS 3631,
- components to achieve a 15-year durability performance. Weatherboards in long lengths, with all knots excluded.
- 2.5 BOARD AND BATTEN In long lengths to profile detailed with species and grading to the requirements of NZS 3602, NZS
- Machine folded aluminium/zinc coated steel sheet to profile of weatherboard and mitred corner joints.
- Machine folded half-hard copper sheet to profile of weatherboard and mitred corner joints. Finishes
- 3.12 FIXING BEVEL BACK WEATHERBOARDS For rebated bevel back boards ensure a minimum gap of 2mm at the overlap between successive
- boards. Nail weatherboards to every fixing point with one nail just clear of the lap. Weatherboards should be fixed in full lengths where possible, stagger end joints across adjacent boards. Where
- External corners for horizontal weatherboards or mitred external corners with either a back flashing in accordance to NZBC E2/AS1, Figure 9.4.4.4B: External corners for horizontal weatherboards or a
- corner soaker in accordance to NZBC E2/AS1, Figure 9.4.4.4A: Corner soakers for bevel-back weatherboards. Back flash internal corners in accordance to NZBC E2/AS1, Figure 9.4.4.5: Internal
- corners for horizontal or vertical weatherboards, either scribe and notch internal corner or use 'W' internal corner flashing.
- 3.13 FIXING RUSTICATED WEATHERBOARDS Adjust vertical set-out to provide a minimum 2mm expansion gap at the overlap between successive
- 9.4.4.4B: External corners for horizontal weatherboards. Back flash internal corners in accordance to NZBC E2/AS1, Figure 9.4.4.5: Internal corners for horizontal or vertical weatherboards, either
- 3.14 FIXING VERTICAL SHIPLAP WEATHERBOARDS Adjust horizontal set-out to ensure there is a minimum 2mm expansion gap at the overlap between
- corners for vertical weatherboards. Back flash internal corners in accordance to NZBC E2/AS1, Figure 9.4.4.5: Internal corners for horizontal or vertical weatherboards, either scribe and notch
- 3.15 FIXING BOARD AND BATTEN Fit boards with a 5mm to 8mm gap between boards and with weather grooves to boards & battens
- 4.5 WEATHERBOARDS Location: ~
- 4.6 BOARD AND BATTEN Location: ~
- NZS 3617 Profiles of weatherboards, fascia boards and flooring NZS 4251.1 Solid plastering: Cement plasters for walls, ceilings and soffits
- 2.32 SHIPLAP WEATHERBOARDS Shiplap timber weatherboard profile as per NZS 3617 or as detailed. In long lengths with species
- 3.30 FIXING SHIPLAP WEATHERBOARDS AS SOFFIT CLADDING Adjust set-out to ensure there is a 2mm expansion gap between successive boards. Using full
- Shiplap Weatherboard soffit cladding 4.1 SHIPLAP WEATHERBOARD - SOFFIT CLADDING
- Installation - IKO Enertherm ALU board, with weatherboard cladding, fibre cement sheet cladding, metal profile cladding or similar lightweight cladding styles
Project Specifications (PDF, 29.9MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.
From the documents of BC251332 read 19 Nov 2026
- Value of work
- $12.9m estimated on the application form, GST included
- Designer
- Richard Andrews - Patterson Associates
richard@pattersons.com
+64 9 303 4004 - Engineer
- Peter Hogan - Holmes NZ LP
peterh@holmesgroup.com
+64 27 4331057 - Lodged by
- Patterson Associates Ltd (The owner has authorised Pattersons (architects) to make this application on their behalf.)
richard@pattersons.com
09 303 4004 - Applicant
- Owner
shane.muir@trojanholdings.co.nz
021797784
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding