1 Jessies Crescent Wanaka 9305
Queenstown Lakes · property 17866 · Lot 3 DP 319220 - 0.115700 Ha CT- 75605
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| RM260782 Resource | Construct Two Residential Units Breaching The Site Separation, Building Coverage, Recession Plane, Earthworks And Transport Standards, And For Consent To Use Each For Rva For Up To 120 Nights Per Annum + Subsequently Undertake A Two-Lot Subdivision + S221 To Cancel Consent Notice 5590070.2 At 1 Jessies Crescent, Wanaka | Jessies Build Limited And S & L Le Heron | Decision Issued | 14 Oct 2026 |
| EA260782 | Jessies Build Limited And S & L Le Heron Engineering Acceptance In Relation To Construct Two Residential Units Breaching The Site Separation, Building Coverage, Recession Plane, Earthworks And Transport Standards, And For Consent To Use Each For Rva For Up To 120 Nights Per Annum Subsequently Undertake A Twolot Subdivision S221 To Cancel Consent Notice 5590070.2 At 1 Jessies Crescent, Wanaka | Being Vetted | ||
| BC261465 Building | Construction 2 X Detached Dwellings | Waiting for Further Information |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of RM260782 read 19 Nov 2026
- Lodged by
- Erin Stagg - Edgar Planning
erin@edgarplanning.co.nz
027 251 1921 - Applicant
- Jessies Build Limited And S & L Le Heron
sam@figureandground.co.nz
020 4056 3884
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- including schist and shiplap timber. The buildings will have gable roofs and maximum height of 7.2m. An assessment against the Residential Desing Guidelines has been undertaken by Figure
AEE 26.076 Jessies Build (PDF, 3.5MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.
From the documents of BC261465 read 18 Nov 2026
- Designer
- Sam Coneele
sam@figureandground.co.nz
02040563884 - Engineer
- Alexander Loye
alex@tetrad.co.nz
0274257708 - Licensed: Design
- Sam Conelle
- Lodged by
- Figure and Ground
ashleigh@figureandground.co.nz
03 352 4333 - Applicant
- Owner
sam@figureandground.co.nz
02040563884
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- CEDAR: 140x45 H1.2 SG8 STUDS @ 400 crs FOR
- DWANGS @ 800 crs FOR CEDAR EXTRACTION FAN POSITIONS, DUCTED
- GUTTER OVER CEDAR FASCIA COLORSTEEL 1/2 ROUND
- GUTTER OVER CEDAR FASCIA 0.40 BMT COLORSTEEL KAHU ROOFING OVER
- HORIZONTAL CEDAR WEATHERBOARDS ON 20mm CAVITY SYSTEM ON BUILDING PAPER ON H1.2
- HORIZONTAL CEDAR WEATHERBOARDS; STAIN FINISH OVER 20mm CAVITY
- 9mm CEDAR T&G CEILING LINING TO TIMBER CEILING BATTENS @600max.crs
- 9mm CEDAR T&G CEILING LINING TIMBER CEILING BATTENS @600m
- WALL BASE - CEDAR. 6
- INT CORNER - CEDAR. 5
- WINDOW SILL - CEDAR. 2
- WINDOW HEAD - CEDAR. 1
- WINDOW JAMB - CEDAR. 3
- EXT CORNER - CEDAR. 4
- BEAM - CEDAR. 8
- BARGE - CEDAR. 7
- WINDOW JAMB - CEDAR. 13
- BARGE - CEDAR. 10
- CEDAR HORIZONTAL WEATHERBOARD OVER H3.1 20mm CAVITY SYSTEM ON
- 40x20 VERTICAL CEDAR BATTENS @ EQUAL CENTRES CEDAR HORIZONTAL WEATHERBOARD
- 40x20 VERTICAL CEDAR BATTENS @ EQUAL CENTRES
- 180x20 CEDAR BARGE BARGE FLASHING WITH CLADDING
- CEDAR CLASHED AROUND 200X90 ENGINEERED BEAM, 20MM
- CEDAR CLASHED AROUND 100 ENGINEERED SHS WITH
- SCREWS, 20MM CEDAR CLASHED AROUND
- 9mm CEDAR SOFFIT LINING FIXED TO UNDERSIDE RAFTERS
- EAVE - CEDAR. 14
- EAVE - CEDAR. 15
- EAVE - CEDAR. 16
- 45x45 VERTICAL CEDAR BATTENS @ EQUAL CENTRES
- CEDAR CLASHED AROUND 180x20 CEDAR BARGE
- 40x20 VERTICAL CEDAR BATTENS @ EQUAL CENTRES INSULATED GARAGE
- 180x20 CEDAR BARGE COLORSTEEL HALF ROUND GUTTER
- 180x20 CEDAR BARGE CEDAR WEATHERBOARD SOFFIT LINING TO
- INT CORNER - CEDAR / STONE. SCALE 1:5
- Hermpac Weatherboard Cladding Systems ........................................................................35 GIB® Plasterboard Linings...................................................................................................40
- 3617:1979(NZS) Specification for profiles of weatherboards, fascia boards, and flooring
- - Cedar Clears (Western Red Cedar, Thuja plicata) Figure & Ground 1 Jessies Crescent Issued for Consent
- 5.6 Hermpac Weatherboard Cladding Systems 5.6.1 Scope
- Supply and install the Hermpac Pacific Limited Weatherboard System, as specified herein, to the walls identified on the drawings, complete with all accessories and trim. For the purpose of this
- 5.6.2 Horizontal Weatherboard Horizontal Rusticated Weatherboard
- Supply and install the Hermpac Horizontal Rusticated Weatherboard Cavity System, as specified herein, to the walls identified on the drawings, complete with all accessories and trim. All aspects of
- The Hermpac Rusticated Weatherboard Cavity System is CodeMark assured. No substitutions or deletions are permitted for the Hermpac Horizontal Rusticated Weatherboard
- Western Red Cedar Weatherboard Profile ~as identified on the accompanying drawings
- Timber Cavity Battens - Horizontal Weatherboards, 20mm Cavity Timber Cavity Battens - to form a nominal 20mm deep drained cavity for Hermpac horizontal
- weatherboards. 40x20mm, minimum H3.2 treated Radiata pine cavity battens. Fix timber cavity battens to stud with 40 x 2.5mm hot-dipped galvanised flat head nails or stainless
- installed by others, and to install Hermpac Weatherboard Cladding System as required. 5.6.6 Workmanship
- Work (RBW) memorandum and the associated Hermpac Weatherboard Cladding System, Product Installation Check List. Issue a copy of the RBW document to the Building Consent Authority and to
- when installing Hermpac weatherboards. 5.6.7 Delivery & Handling
- Store weatherboards and accessories undercover, flat and true, clear of the ground by at least 150mm and supported on dry and clean timber bearers at maximum 900mm centres in accordance
- with Hermpac recommendations. Keep stored weatherboards and accessories dry and protected from damage and contamination, and free from bending or excessive compression.
- Do not use damaged or defective weatherboards or accessories. Dock any oversized knots, unacceptable or unrequired grade characteristic, or damaged areas of
- weatherboard. Do not install weatherboards during periods of wet weather. Double seal all cut ends and fresh cut timber with selected exterior coating. Some grades of timber will require more docking
- Handle weatherboards in accordance with the manufacturer's recommendations and in a manner that prevents damage and surface marking.
- Install the specified Hermpac Weatherboard Cladding System, complete with accessories, in accordance with the Hermpac installation requirements and technical literature and as shown on the
- Weatherboard soaker and/or flashing material compatibility shall be in accordance with NZBC E2/AS1 2.2, and as shown on the drawings.
- All internal and external weatherboard corner junctions, inter-storey junctions, and weatherboard trim and accessories, shall be constructed and installed to the details shown on the drawings.
- Always keep Hermpac weatherboard cladding lines consistent and true along walls and around corners.
- Hermpac Rusticated Weatherboard Cavity - Fixed over a Flexible Wall Underlay on Timber framing Preparation
- Hermpac Rusticated Weatherboards installed over a nominal 18mm cavity drain over a flexible wall underlay:
- Carefully set-out and fix the base weatherboard to the timber studs through the cavity battens, level along the base line, minimum 50mm or as detailed, below the bottom plate or floor structure.
- Install full length weatherboards where possible. From the base board upwards, level and true the weatherboards to the cavity battens.
- Where joints are unavoidable, scarf the weatherboards at 30º directly over a stud line, and fix weatherboard ends as specified and just clear of the scarf join.
- Overlap, joint and fix cavity-installed Hermpac Rusticated Weatherboards in accordance with Hermpac installation requirements and as detailed on the drawings. NB: Ensure weatherboard end-
- Fix Hermpac Vertical Shiplap Weatherboards Fix Hermpac Weatherboards with Grade 316 Stainless Steel Annular Grooved Rose Head Nails in
- The nail shank must be minimum 3.15mm diameter for cavity-fixed weatherboards, or 2.8mm diameter for direct-fixed weatherboards.
- Ensure the weatherboards are set-out with an overlap of 25mm, with a 2mm expansion gap between boards at the overlap.
- Single fix weatherboards at every fixing point, with nails driven in a slight upward slope, located 30- 35mm from the edge of the weatherboard, and no closer than 32mm from the end of the board.
- Check that the specified Hermpac Weatherboard System has been correctly installed and fixed to the layout and details shown on the drawings; that all joints, associated trim and accessories finished
- Weatherboard Cladding System Product Installation Check List. Issue a copy of the RBW document to the Building Consent Authority and to the Main Contractor.
Plans (PDF, 8.5MB)Project Specification (PDF, 0.5MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.