← Board

31 Kahiwi Drive Lower Shotover 9304

Queenstown Lakes · property 171300 · LOT 29 DP 599390 - 0.206900 Ha CT- 1169556 LOT 204 DP 599390 - 0.093900 Ha CT- Multiple

Every consent eDocs lists on this property

Consent Description Applicant Status Status date
RM260230 Resource Application Under Section 127 Of The Resource Management Act 1991 (Rma) To Change Conditions 1, 13 (Specifically 13C, J, And K), And 19 Of Rm250021 To Remove The Need For Road Widening With The Private Ways At Kahiwi Drive, Lower Shotover, Queenstown Koko Ridge Limited Decision Issued 5 May 2026
BC261461 Building Construction Of Single Storey Multiunit Dwelling With Attached Garage PIC/PIM Issued

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of BC261461 read 18 Nov 2026

Value of work
$1.4m estimated on the application form, GST included
Designer
Christina Luo
info@arclightarch.co.nz
0210529968
Engineer
Andrew Lind
andy@engco.co.nz
027 545 5494
Licensed: Design
Tiankun Lu BP135284
Lodged by
Christina Luo (Designer and authorised agent (Signed Owner’s Authorisation letter attached))
info@arclightarch.co.nz
0210529968
Applicant
Owner
mialzhang0303@hotmail.com
0223458808
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • VERTICAL SHIPLAP WEATHERBOARD
  • 2.2 VERTICAL SHIPLAP WEATHERBOARD
  • Selected timber vertical shiplap weatherboard on 20mm thickness timber cavity batten on selected wall underlay on wall framing
  • that the weatherboard is hard against the back of
  • mm Expansion \ contraction gap between Weatherboards Nail
  • Note: Hermpac Cedar weatherboards fixed with jolt head nails are limited to use in NZS 3604 Wind Zones up to and including Medium when dwangs or structurally fixed Vertibat cavity battens are at maximum 480 mm centres, and NZS 3604 Wind Zones up to, and
  • Hermpac DuraLarch and Ashin-Dura weatherboards fixed with jolt head nails are limited to use in NZS 3604 Wind Zones up to and including Extra High when dwangs or structurally fixed Vertibat cavity battens are at maximum 480 mm centres.
  • AND WEATHERBOARD BUILDING UNDERLAY
  • Vertical Shiplap Weatherboard WALL UNDERLAY
  • BRICK VENEER - ALUMINIUM WINDOW HEAD WITH WEATHERBOARD 1
  • SHIPLAP WEATHBERBOARD - BRICK VENEER INTERNAL CORNER 10
  • Wall Cladding: Vertical shiplap Cedar weatherboard, Brick Veneer Roofing: Metalcraft T-Rib Roofing
  • Hermpac Weatherboard Cladding Systems.........................................................142 External Window & Door Joinery .............................................................................175
  • Product Technical Statement - Vertical Shiplap Cavity........................................299 Installation Specifications - Vertical Shiplap - Direct Fixed ..................................299
  • HermPac -Vertical Shiplap PTS ...........................................................................299 Product installation Check List .............................................................................299
  • BRANZ Appraisal 1181 – Vertical Shiplap ...........................................................299 CODEMARK CMNZ30138 Vertical Shiplap .........................................................299
  • Installation Specifications - Vertical Shiplap Cavity Fixed....................................299 Product installation Check List .............................................................................299
  • 3617:1979(NZS) Specification for profiles of weatherboards, fascia boards, and flooring
  • - Cedar Clears (Western Red Cedar, Thuja plicata) - Rimu - (NZ Red Pine)
  • Sectional, overhead, ply and polystyrene sandwich panel, cedar TG & V faced, garage door(s) as shown and noted on the drawings, installed complete with automatic opening door
  • Provide a minimum 150mm shiplap at side and end laps, ensuring all laps are formed to shed water to the exterior. The underlay must be installed tight and without creases or sagging,
  • 8.11 Hermpac Weatherboard Cladding Systems 8.11.1 Scope
  • Supply and install the Hermpac Pacific Limited Weatherboard System, as specified herein, to the walls identified on the drawings, complete with all accessories and trim. For the purpose
  • 8.11.2 Vertical Weatherboard Vertical Shiplap Weatherboard
  • Supply and install the Hermpac Vertical Shiplap Weatherboard Cavity System, as specified herein, to the walls identified on the drawings, complete with all accessories and trim. All
  • The Hermpac Vertical Shiplap Weatherboard Cavity System is CodeMark assured. Arclight Architecture Limited LOT 291- 31 KAHIWI DRIVE,
  • No substitutions or deletions are permitted for the Hermpac Vertical Shiplap Weatherboard Cavity System.
  • Vertical Shiplap Weatherboard Supply and install the Hermpac Vertical Shiplap Weatherboard System, as specified herein,
  • No substitutions or deletions are permitted for the Hermpac Vertical Shiplap Weatherboard System.
  • Vertical Shiplap CedarOne Weatherboard Supply and install the Hermpac Vertical Shiplap CedarOne Evolve Weatherboard Cavity
  • The Hermpac Vertical Shiplap CedarOne Evolve Weatherboard Cavity System is CodeMark assured.
  • No substitutions or deletions are permitted for the Hermpac Vertical Shiplap CedarOne Evolve Weatherboard Cavity System.
  • Vertical Shiplap CedarLine Evolve Weatherboard Supply and install the Hermpac Vertical Shiplap CedarOne Evolve Weatherboard Cavity
  • The Hermpac Vertical Shiplap CedarLine Evolve Weatherboard Cavity System is CodeMark assured.
  • No substitutions or deletions are permitted for the Hermpac Vertical Shiplap CedarLine Evolve Weatherboard Cavity System.
  • Vertical Shiplap CedarOne Mantle Weatherboard Supply and install the Hermpac Vertical Shiplap CedarOne Mantle Weatherboard Cavity
  • The Hermpac Vertical Shiplap CedarOne Mantle Weatherboard Cavity System is CodeMark assured.
  • No substitutions or deletions are permitted for the Hermpac Vertical Shiplap CedarOne Mantle Weatherboard Cavity System.
  • Vertical Shiplap CedarLine Mantle Weatherboard Supply and install the Hermpac Vertical Shiplap CedarOne Mantle Weatherboard Cavity
  • The Hermpac Vertical Shiplap CedarLine Mantle Weatherboard Cavity System is CodeMark assured.
  • No substitutions or deletions are permitted for the Hermpac Vertical Shiplap CedarLine Mantle Weatherboard Cavity System
  • Board & Batten Weatherboard Supply and install the Hermpac Board & Batten Weatherboard Cavity System, as specified
  • The Hermpac Board & Batten Weatherboard Cavity System is CodeMark assured. No substitutions or deletions are permitted for the Hermpac Board & Batten Weatherboard
  • Vertical Random Width Weatherboard Supply and install the Hermpac Vertical Random Width Weatherboard Cavity System, as
  • The Hermpac Vertical Random Width Weatherboard Cavity System is CodeMark assured. No substitutions or deletions are permitted for the Hermpac Vertical Random Width
  • Weatherboard Cavity System Vertical Random Width CedarOne Weatherboard
  • Supply and install the Hermpac Vertical Random Width CedarOne Evolve Weatherboard Cavity System, as specified herein, to the walls identified on the drawings, complete with all
  • The Hermpac Vertical Random Width CedarOne Evolve Weatherboard Cavity System is CodeMark assured.
  • CedarOne Evolve Weatherboard Cavity System. Vertical Random Width CedarLine Evolve Weatherboard
  • Supply and install the Hermpac Vertical Random Width CedarOne Evolve Weatherboard Arclight Architecture Limited LOT 291- 31 KAHIWI DRIVE,
  • The Hermpac Vertical Random Width CedarLine Evolve Weatherboard Cavity System is CodeMark assured.
  • CedarLine Evolve Weatherboard Cavity System. Vertical Random Width CedarOne Mantle Weatherboard
  • Supply and install the Hermpac Vertical Random Width CedarOne Mantle Weatherboard Cavity System, as specified herein, to the walls identified on the drawings, complete with all
  • The Hermpac Vertical Random Width CedarOne Mantle Weatherboard Cavity System is CodeMark assured.
  • CedarOne Mantle Weatherboard Cavity System. Vertical Random Width CedarLine Mantle Weatherboard
  • The Hermpac Vertical Random Width CedarLine Mantle Weatherboard Cavity System is CodeMark assured.
  • CedarLine Mantle Weatherboard Cavity System. Vertical Random Width & Depth Weatherboard
  • Supply and install the Hermpac Vertical Random Width & Depth Weatherboard Cavity System, as specified herein, to the walls identified on the drawings, complete with all
  • The Hermpac Vertical Random Width & Depth Weatherboard Cavity System is CodeMark assured.
  • Weatherboard Cavity System. Arclight Architecture Limited LOT 291- 31 KAHIWI DRIVE,
  • 8.11.3 Vertical Accoya Weatherboard Vertical Shiplap Weatherboard
  • The Hermpac Vertical Shiplap Weatherboard Cavity System is CodeMark assured. No substitutions or deletions are permitted for the Hermpac Vertical Shiplap Weatherboard
  • Weatherboard Cavity System Vertical Random Width & Depth Weatherboard
  • Weatherboard Cavity System 8.11.4 Timber Species & Profile
  • Western Red Cedar Weatherboard Profile ~as identified on the accompanying drawings
  • Yellow Cedar Weatherboard Profile ~as identified on the accompanying drawings
  • Weatherboard Profile ~as identified on the accompanying drawings Grade ~as identified on the accompanying drawings
  • Weatherboard Profile ~as identified on the accompanying drawings Grain/Cut – Mixed grain
  • Weatherboard Profile ~as identified on the accompanying drawings Grain/Cut - Quartersawn
  • Accoya Weatherboard Profile ~as identified on the accompanying drawings
  • Accoya Grey Weatherboard Profile ~as identified on the accompanying drawings
  • Weatherboard Profile ~as identified on the accompanying drawings Grade - S&B
  • Hermpac Cover Battens - Shiplap Weatherboard Hermpac Vertical Shiplap Weatherboard Cover Battens - Selected to suit the details shown
  • on the drawings. Fixed with 50 x 2.8mm nails matched with the selected weatherboard fixing. Unless specified otherwise on the drawings, timber species, grade and surface finish to match
  • weatherboards. Hermpac External Corner Mouldings - Shiplap Weatherboard
  • Hermpac Vertical Shiplap Weatherboard External Corner Moulding - Selected to suit the details shown on the drawings. Nail fixings matched with the selected weatherboard fixing.
  • weatherboards. Hermpac Internal Corner Mouldings - Shiplap Weatherboard
  • Hermpac Vertical Shiplap Weatherboard Internal Corner Moulding - Selected to suit the details shown on the drawings. Nail fixings matched with the selected weatherboard fixing.
  • weatherboards. Hermpac Eave Mouldings - Shiplap Weatherboard
  • Hermpac Vertical Shiplap Weatherboard Eave Moulding - Selected to suit the details shown on the drawings. Nail fixings matched with the selected weatherboard fixing. Unless specified
  • otherwise on the drawings, timber species, grade and surface finish to match weatherboards. Hermpac Cover Battens - Board & Batten Weatherboard
  • Hermpac Board & Batten Weatherboard Cover Battens - Selected to suit the details shown on the drawings. Fixed with 50 x 2.8mm nails matched with the selected weatherboard fixing.
  • weatherboards. Aluminium corner flashings to suit moulding (refer www.hermpac.co.nz for required flashing size).
  • Hermpac Eave Mouldings - Board & Batten Weatherboard Hermpac Board & Batten Weatherboard Eave Moulding - Selected to suit the details shown
  • on the drawings. Nail fixings matched with the selected weatherboard fixing. Unless specified otherwise on the drawings, timber species, grade and surface finish to match weatherboards.
  • Hermpac vertical weatherboards. Vertibat V1 - 40 x 20mm thick, and Vertibat V2 - 70mm x 20mm thick, bevelled and castellated timber cavity battens; incorporating 20mm wide x 5mm
  • Vertibat cavity battens is also available manufactured from Western Red Cedar. Fix Vertibat 20mm thick cavity battens along dwang lines, etc., with 40 x 2.5mm hot-dipped
  • installed by others, and to install Hermpac Weatherboard Cladding System as required. 8.11.8 Workmanship
  • Building Work (RBW) memorandum and the associated Hermpac Weatherboard Cladding System, Product Installation Check List. Issue a copy of the RBW document to the Building
  • referenced and followed when installing Hermpac weatherboards. 8.11.9 Delivery & Handling
  • Store weatherboards and accessories undercover, flat and true, clear of the ground by at least 150mm and supported on dry and clean timber bearers at maximum 900mm centres in
  • accordance with Hermpac recommendations. Keep stored weatherboards and accessories dry and protected from damage and contamination, and free from bending or excessive
  • Do not use damaged or defective weatherboards or accessories. Dock any oversized knots, unacceptable or unrequired grade characteristic, or damaged
  • areas of weatherboard. Do not install weatherboards during periods of wet weather. Double seal all cut ends and fresh cut timber with selected exterior coating. Some grades of timber
  • Handle weatherboards in accordance with the manufacturer's recommendations and in a manner that prevents damage and surface marking.
  • Install the specified Hermpac Weatherboard Cladding System, complete with accessories, in accordance with the Hermpac installation requirements and technical literature and as shown
  • Weatherboard soaker and/or flashing material compatibility shall be in accordance with NZBC E2/AS1 2.2, and as shown on the drawings.
  • All internal and external weatherboard corner junctions, inter-storey junctions, and weatherboard trim and accessories, shall be constructed and installed to the details shown on
  • Always keep Hermpac weatherboard cladding lines consistent and true along walls and around corners.
  • Hermpac Vertical Shiplap Weatherboard Cavity-Fixed over a Flexible Wall Underlay on Timber framing
  • Hermpac Vertical Shiplap Weatherboards installed over a cavity drain (20mm/40mm/45mm) over a flexible wall underlay:
  • As specified and shown on the drawings, fix shiplap weatherboards to the timber framing through 20mm thick Vertibat cavity battens, or fix to Vertibat 40mm or 45mm thick cavity
  • Install full length weatherboards where possible. Where joints are unavoidable, scarf the weatherboards at 30º over a cavity batten line, and fix weatherboard ends, with the top board
  • Overlap, joint and fix cavity-installed Hermpac Shiplap Weatherboards in accordance with Hermpac installation requirements and as detailed on the drawings. NB: Ensure
  • weatherboard end-grains are double coated. Hermpac Vertical Shiplap Weatherboard Cavity-Fixed over a Rigid Wall Underlay on Timber
  • Hermpac Vertical Shiplap Weatherboards installed over a cavity drain (20mm/40mm/45mm) over a rigid wall underlay:
  • weatherboard end-grains are double coated. Hermpac Vertical Shiplap Weatherboard Direct-Fixed over a Flexible Wall Underlay on
  • Hermpac Vertical Shiplap Weatherboards direct-fixed to timber framing over a flexible wall underlay:
  • Fix weatherboards to the timber framing, and maintain the base overhang minimum 50mm, or as detailed, below the bottom plate or floor structure.
  • Install full length weatherboards where possible. Where joints are unavoidable, scarf the weatherboards at 30º over a nog/dwang line, and fix weatherboard ends, with the top board
  • Overlap, joint and fix weatherboards in accordance with the manufacturer's recommendations and as detailed on the drawings. NB: Ensure weatherboard end-grains are double coated.
  • Check for and eliminate any creep and/or spread of shiplap weatherboards during installation. Internal and external corner junctions, weatherboard trim and accessories, all constructed and
  • Hermpac Vertical Shiplap Weatherboard Direct-Fixed over a Rigid Wall Underlay on Timber framing
  • Hermpac Vertical Shiplap Weatherboards direct-fixed to timber framing over a rigid wall underlay:
  • Fix weatherboards to the timber framing through the rigid underlay, and maintain the base overhang minimum 50mm, or as detailed, below the bottom plate or floor structure.
  • Check for and eliminate any creep and/or spread of shiplap weatherboards during installation. Arclight Architecture Limited LOT 291- 31 KAHIWI DRIVE,
  • Internal and external corner junctions, weatherboard trim and accessories, all constructed and installed to the details shown on the drawings.
  • Hermpac Board & Batten Weatherboard Cavity-Fixed over a Flexible Wall Underlay on Timber framing
  • Hermpac Board & Batten Weatherboards installed over a cavity drain (20mm/40mm/45mm) over a flexible wall underlay:
  • joint. NB: Ensure weatherboard end-grains are double coated. Check for and eliminate any creep and/or spread of cladding boards during installation.
  • Hermpac Board & Batten Weatherboard Cavity-Fixed over a Rigid Wall Underlay on Timber framing
  • Hermpac Board & Batten Weatherboards installed over a cavity drain (20mm/40mm/45mm) over a rigid wall underlay:
  • Fix Hermpac Vertical Shiplap Weatherboards Fix Hermpac Weatherboards with Grade 316 Stainless Steel Annular Grooved Rose Head
  • The nail shank must be minimum 3.15mm diameter for cavity-fixed weatherboards, or 2.8mm diameter for direct-fixed weatherboards.
  • Ensure the weatherboards are set-out with an overlap of 25mm, with a 2mm expansion gap between boards at the overlap.
  • Single fix weatherboards at every fixing point, with nails driven in a slight upward slope, located 30-35mm from the edge of the weatherboard, and no closer than 32mm from the end
  • Fix Hermpac Vertical Shiplap Weatherboards Fix Hermpac Vertical Shiplap Weatherboards with Silicon Bronze Annular Grooved Rose
  • Fix Hermpac Vertical Shiplap Weatherboards Fix Hermpac Vertical Shiplap Weatherboards with Grade 316 Stainless Steel Annular
  • Ensure the weatherboards are set-out with an overlap of 25mm, with a 2mm expansion gap between the boards at the overlap.
  • Fix Hermpac Vertical Shiplap Weatherboards Arclight Architecture Limited LOT 291- 31 KAHIWI DRIVE,
  • Fix Hermpac Vertical Shiplap Weatherboards with Silicon Bronze Annular Grooved Flat Head Nails in accordance with Hermpac fixing requirements and as shown on the drawings.
  • Fix paint-finished Hermpac Vertical Shiplap Weatherboards Fix paint-finished Hermpac Vertical Shiplap Weatherboards with Grade 316 Stainless Steel
  • Single fix weatherboards at every fixing point, with nails driven in a slight upward slope, located 30-35mm (35-40mm for Multisplay profiles) from the edge of the weatherboard, and
  • Fix Hermpac Shiplap Weatherboards Fix Hermpac Shiplap Weatherboards with Grade 316 Stainless Steel finish as identified on
  • Ensure the weatherboards are set-out with an overlap of 32mm. Single fix weatherboards at every fixing point, with screws driven in a slight upward slope,
  • located 35-40mm from the bottom edge of the weatherboard, and no closer than 32mm from the end of the board.
  • Fix Hermpac Vertical Shiplap Weatherboards Fix Hermpac Vertical Shiplap Weatherboards with Hermpac Crown Head, annular grooved
  • Fix Hermpac Board & Batten Weatherboards Arclight Architecture Limited LOT 291- 31 KAHIWI DRIVE,
  • Fix Hermpac Board & Batten Weatherboards with Grade 316 Stainless Steel Annular Grooved Hermpac Crown Head Nails in accordance with Hermpac fixing requirements and as
  • Ensure the weatherboards are set-out with a nominal 7mm gap between boards. Single fix in centre of the board width at maximum 480mm vertical centres, with nails driven in
  • Fix Hermpac Board & Batten Weatherboards with Silicon Bronze Annular Grooved Hermpac Crown Head Nails in accordance with Hermpac fixing requirements and as shown on the
  • Fix Hermpac Cedar Board & Batten Weatherboards Fix Hermpac Cedar Board & Batten Weatherboards with Grade 316 Stainless Steel Annular
  • Fix Hermpac Board & Batten Weatherboards Fix Hermpac Board & Batten Weatherboards with Silicon Bronze Annular Grooved Rose
  • Fix Hermpac Board & Batten Weatherboards Fix Hermpac Board & Batten Weatherboards with Grade 316 Stainless Steel Annular
  • Fix Hermpac Board & Batten Weatherboards Fix Hermpac Board & Batten Weatherboards with Silicon Bronze Annular Grooved Flat Head
  • Fix paint-finished Hermpac Board & Batten Weatherboards Fix paint-finished Hermpac Board & Batten Weatherboards with Grade 316 Stainless Steel
  • Fix Hermpac Board & Batten Weatherboards Fix Hermpac Board & Batten Weatherboards with Grade 316 Stainless Steel or Bronzed
  • Fix Hermpac Bevelback Weatherboards Fix Hermpac Bevelback Weatherboards, with Grade 316 Stainless Steel Annular Grooved
  • Ensure the weatherboards are set-out with an overlap of 32mm. Single fix weatherboards at every fixing point, with nails driven in a slight upward slope,
  • Fix Hermpac Bevelback Weatherboards Fix Hermpac Bevelback Weatherboards with Silicon Bronze Annular Grooved Hermpac
  • Rose Head Nail, Stainless Steel - Cedar Bevelback Weatherboard Fix Hermpac Cedar Bevelback Weatherboards with Grade 316 Stainless Steel Annular
  • Fix Hermpac Bevelback Weatherboards Fix Hermpac Bevelback Weatherboards with Silicon Bronze Annular Grooved Rose Head
  • Fix Hermpac Bevelback Weatherboards Fix Hermpac Bevelback Weatherboards with Grade 316 Stainless Steel Annular Grooved Flat
  • Fix Hermpac Bevelback Weatherboards Fix Hermpac Bevelback Weatherboards with Silicon Bronze Annular Grooved Flat Head
  • Fix paint-finished Hermpac Bevelback Weatherboards Fix paint-finished Hermpac Bevelback Weatherboards with Grade 316 Stainless Steel
  • Fix Hermpac Cedar Bevelback Weatherboards Fix Hermpac Cedar Bevelback Weatherboards with Grade 316 Stainless Steel finish as
  • Ensure the weatherboards are set-out with an overlap of 32mm. Arclight Architecture Limited LOT 291- 31 KAHIWI DRIVE,
  • Single fix weatherboards at every fixing point, with screws driven in a slight upward slope, located 35-40mm from the bottom edge of the weatherboard, and no closer than 32mm from
  • Fix Hermpac Rebated Bevelback Weatherboards Fix Hermpac Rebated Bevelback Weatherboards with Grade 316 Stainless Steel Annular
  • Ensure the weatherboards are set-out with a minimum overlap of 25mm, with a 2mm expansion gap between boards at the overlap. All nail fixings shall be pre-drilled a maximum
  • Single fix weatherboards at every fixing point, with nails driven in a slight upward slope, located 30-32mm from the bottom edge of the weatherboard, and no closer than 32mm from
  • Crown Head Nail, Silicon Bronze - Cedar Rebated Bevelback Weatherboard Fix Hermpac Cedar Rebated Bevelback Weatherboards with Silicon Bronze Annular Grooved
  • Ensure the weatherboards are set-out with a minimum overlap of 25mm, with a 2mm expansion gap between boards at the overlap.
  • Fix Hermpac Rebated Bevelback Weatherboards Fix Hermpac Rebated Bevelback Weatherboards with Silicon Bronze Annular Grooved Rose
  • Fix Hermpac Rebated Bevelback Weatherboards Fix Hermpac Rebated Bevelback Weatherboards with Silicon Bronze Annular Grooved Flat
  • Fix paint-finished Hermpac Rebated Bevelback Weatherboards Fix paint-finished Hermpac Rebated Bevelback Weatherboards with Grade 316 Stainless
  • Fix Hermpac Rebated Bevelback Weatherboards Fix Hermpac Rebated Bevelback Weatherboards with Grade 316 Stainless Steel finish as
  • Fix Hermpac Rusticated Weatherboards Fix Hermpac Rusticated Weatherboards with Grade 316 Stainless Steel Annular Grooved
  • Single fix weatherboards at every fixing point, with nails driven in a slight upward slope, located 30-35mm from the bottom edge of the weatherboard, and no closer than 32mm from
  • Fix Hermpac Rusticated Weatherboards Fix Hermpac Rusticated Weatherboards with Silicon Bronze Annular Grooved Hermpac
  • Single fix weatherboards at every fixing point, with nails driven in a slight upward slope, located 30-35mm from the bottom edge of the weatherboard and no closer than 32mm from
  • Fix Hermpac Rusticated Weatherboards Fix Hermpac Rusticated Weatherboards with Silicon Bronze Annular Grooved Rose Head
  • Fix Hermpac Rusticated Weatherboards Fix Hermpac Rusticated Weatherboards with Grade 316 Stainless Steel Annular Grooved Flat
  • Fix Hermpac Rusticated Weatherboards Fix Hermpac Rusticated Weatherboards with Silicon Bronze Annular Grooved Flat Head Nails
  • Fix paint-finished Hermpac Cedar Rusticated Weatherboards Fix paint-finished Hermpac Cedar Rusticated Weatherboards with Grade 316 Stainless Steel
  • Fix Hermpac Rusticated Weatherboards Fix Hermpac Rusticated Weatherboards with Grade 316 Stainless Steel finish as identified on
  • Fix Hermpac Splaycut & Multi-Splay Weatherboards Arclight Architecture Limited LOT 291- 31 KAHIWI DRIVE,
  • Fix Hermpac Splaycut & Multi-Splay Weatherboards with Grade 316 Stainless Steel Annular Grooved Hermpac Crown Head Nails in accordance with Hermpac fixing requirements and as
  • Ensure the weatherboards are set-out with an overlap of 25mm (30mm for Multi-Splay profiles), with a 2mm expansion gap between boards at the overlap.
  • Single fix weatherboards at every fixing point, with nails driven in a slight upward slope, located 30-35mm (35-40mm for Multi-Splay profiles) from the bottom edge of the
  • weatherboard, and no closer than 32mm from the end of the board. Nails shall be set flush onto the board surface - not into or below the surface.
  • Fix Hermpac Cedar Splaycut & Multi-Splay Weatherboards Fix Hermpac Cedar Splaycut & Multi-Splay Weatherboards with Silicon Bronze Annular
  • Fix Hermpac Splaycut & Multi-Splay Weatherboards Fix Hermpac Splaycut & Multi-Splay Weatherboards with Grade 316 Stainless Steel Annular
  • Fix Hermpac Splaycut & Multi-Splay Weatherboards Fix Hermpac Splaycut & Multi-Splay Weatherboards with Silicon Bronze Annular Grooved
  • Fix Hermpac Splaycut & Multi-Splay Weatherboards Fix Hermpac Splaycut & Multi-Splay Weatherboards with Grade 316 Stainless Steel finish as
  • Check that the specified Hermpac Weatherboard System has been correctly installed and fixed to the layout and details shown on the drawings; that all joints, associated trim and
  • Weatherboard Cladding System Product Installation Check List. Issue a copy of the RBW document to the Building Consent Authority and to the Main Contractor.
  • 19. Product Technical Statement - Vertical Shiplap Cavity 20. Installation Specifications - Vertical Shiplap - Direct Fixed
  • 21. HermPac -Vertical Shiplap PTS 22. Product installation Check List
  • 27. BRANZ Appraisal 1181 – Vertical Shiplap 28. CODEMARK CMNZ30138 Vertical Shiplap
  • 29. Installation Specifications - Vertical Shiplap Cavity Fixed 30. Product installation Check List

Plans (PDF, 17.5MB)Project Specifications (PDF, 2.0MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.