11 Carrickmore Crescent Wanaka 9382
Queenstown Lakes · property 169190 · LOT 510 DP 607419 - 0.142000 Ha CT- 1197604
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| RM261151 Resource | Construction Of A Residential Unit, Breaching The Earthwork Standards At 11 Carrickmore Crescent, Northlake, Wanaka | G & P Wilson | Formally Received | |
| BC261489 Building | Construction Of A Single Storey Detached Dwelling With Attached Double Garage. | PIC/PIM Issued |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of RM261151 read 18 Nov 2026
- Lodged by
- Nicola Scott, Wanaka Resource Management Ltd
nicolascott@xtra.co.nz
027 443 6114 - Applicant
- G & P Wilson
phillip_is@hotmail.com
gemblem@hotmail.com
021 0329 114
0210 332 688
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- Walls: Vertical Shiplap weatherboards, natural oil stain; and Colorsteel 5-Rib cladding (selected colour to match roofing).
- gabled roof forms (at the required pitch) and materials incorporating natural timber weatherboards and dark, recessive coloured cladding.
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.
- Not read
- no plans
From the documents of BC261489 read 18 Nov 2026
- Value of work
- $800k estimated on the application form, GST included
- Designer
- Richard Vorstermans
rich@hotmail.co.nz
027 2070157 - Engineer
- Wilton Joubert Ltd
johnson@wjl.co.nz
09 527 0196 - Builder
- Phillip Wilson
phillip_is@hotmail.com
0210 332688 - Licensed: Design
- Richard Vorstermans BP114165
- Licensed: Carpentry
- Phil Wilson BP131758
- Lodged by
- Richard Vorstermans (Designer)
rich@hotmail.co.nz
027 2070157 - Applicant
- Owner
phillip_is@hotmail.com
0210 332688
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- 407 TIMBER CLADDING DETAILS 408 TIMBER CLADDING DETAILS
- T Timber Weatherboard Cladding M
- TIMBER SHIPLAP WEATHERBOARDS RUN VERTICALLY ON 20mm H3.1 CAVITY BATTENS @
- Vertical shiplap weatherboards.
- Bevel back timber weatherboard over nominal 20mm drained cavity
- -Timber Weatherboard Cladding. Cedar species with natural oil stain. -Coloursteel Cladding: Coloursteel Flaxpod or Slate or Windsor Grey
- Vertical shiplap weatherboards on castelated horizontal cavity
- Vertical shiplap weatherboard
- Timber Weatherboard / Metal Cladding Internal Corner Junction
- Timber Cladding Details NOV 2026 WILSON & THOMPSON RESIDENCE
- Cavity Fix Vertical Shiplap Weatherboard System CMNZ30036
- Cavity Fix Vertical Shiplap Weatherboard System NOTES:
- All weatherboard fixings pre-drilled maximum 1mm diameter smaller than the nail/screw gauge. All Hermpac timber products, cut ends and edges to be precoated as per Installation Specifications.
- For non-hemmed corner flashings, ensure a minimum 75mm cover to weatherboards beyond the point where BRANZ Bulletin 411 compliant weatherboard lap or rebate combinations terminate at
- Prior to installation, refer to Hermpac Vertical Shiplap Technical Installation Specifications. CMNZ30036
- - All weatherboard fixings pre-drilled maximum 1mm diameter smaller than the nail/screw gauge. - All Hermpac timber products, cut ends and edges to be precoated as per Installation Specifications.
- - For non-hemmed corner flashings, ensure a minimum 75mm cover to weatherboards beyond the point where BRANZ Bulletin 411 compliant weatherboard lap or rebate combinations terminate at
- - Prior to installation, refer to Hermpac Vertical Shiplap Technical Installation Specifications. CMNZ30036
- - Prior to installation, refer to Hermpac Vertical Shiplap Technical Installation Specifications. 20mm
- Timber Weatherboard Top Detail D31
- Timber Weatherboard Base Detail D27
- Hermpac VertiLine Vertical Shiplap Installation Specifications. 100 x 100mm Hermpac
- Hermpac Vertical Shiplap Installation Specifications. Selected Vertibat Cavity
- Cavity Fix Vertical Shiplap Weatherboard System must also be used.
- Timber Weatherboard Cladding...........................................................................................58 Rigid Air Barriers.................................................................................................................60
- 3617:1979(NZS) Specification for profiles of weatherboards, fascia boards, and flooring
- 6.8 Timber Weatherboard Cladding 6.8.1 Scope
- Supply and install the selected Timber Weatherboard Cladding type(s) to the locations shown on the drawings, complete with all accessories. All aspects of this work shall be carried out to comply with
- 6.8.2 Vertical Weatherboard Profile Vertical Shiplap Weatherboard: ex.150mm x 25mm, machined to NZS 3617 and/or BRANZ Bulletin
- Co-ordinate with other trades to ensure that the weatherboards correctly allow for door and window installation, and for the locations of pipes, outlets, and fittings installed by others.
- Vertical Weatherboards Cavity-Fixed on Timber Framing - check all aspects of preparatory works, including, but not limited to:
- correctly in place, and has a maximum moisture content of 20% at the time of weatherboard cladding installation.
- and appropriate for the weatherboard cladding installation. - For cavity construction without a rigid wall underlay and where the studs are at greater than 450mm
- works have been completed that will enable the weatherboards to be installed, and that the work of other trades does not negatively impact on or reduce the minimum clearances required by the NZ
- 6.8.5.1 Vertical Shiplap Weatherboard - Cavity Fix Back flash all internal and external corners as detailed.
- Carefully set-out Vertical Shiplap Weatherboard cladding vertically over the fluted/castelated horizontal cavity battens, to straight plumb lines, and fix to the framing with side laps directed away
- plate or floor structure. Install full length weatherboards boards where possible. Where joints are unavoidable, scarf the weatherboards at 45º and fix to solid framing through the top overlapping board
- Check for and eliminate any creep and/or spread of shiplap weatherboards during installation. Finish Standard Vertical Weatherboards, weatherboard trim, flashings and accessories at internal and
- Upon delivery to site, inspect weatherboards and accessories and reject any items found to be damaged, defective or substandard. Contact the manufacturer/supplier for replacement.
- Store weatherboards, flashings and accessories undercover, flat and true, clear of the ground by at least 150mm and supported on dry, clean timber bearers at maximum 900mm centres, or as recommended
- by the weatherboard manufacturer. Keep stored materials and accessories dry and protected from damage and contamination at all times, and free from bending, distortion or excessive compression. Do
- Do not use damaged or defective weatherboards or accessories. Dock any oversized knots, unacceptable grade characteristics or damaged areas of weatherboard.
- Weatherboards must be dry prior to installation. Do not install weatherboards during periods of wet weather. Seal all cut ends and fresh-cut timber with two coats of the selected exterior primer or coating.
- Handle weatherboards in accordance with the manufacturer's recommendations and in a manner that prevents damage to or deterioration of the material, including surface marking.
Plans (PDF, 9.7MB)Project Specification (PDF, 0.7MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.