Queenstown Lakes · property 167850 · LOT 76 DP 605913 - 0.096500 Ha CT- 1190852

Every consent eDocs lists on this property

Consent Description Applicant Status Status date
DB260307 Construction Of Single Storey Dwelling With Attached Garage And Solid Fuel Fire Development Contribution Notice Sent
BC260307 Building Construction Of Single Storey Dwelling With Attached Garage And Solid Fuel Fire CCC Processing Awaiting Further Information 16 Apr 2026

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of BC260307 read 18 Nov 2026

Value of work
$612k estimated on the application form, GST included
Designer
Craig Garner
office@garnerarchitecture.nz
0273583498
Licensed: Design
Craig Garner BP131065
Lodged by
Latitude Homes (Agent)
jeremy@latitudehomes.co.nz
021942922
Applicant
Owner
info@mdg.co.nz
021840656
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • Selected mber shiplap or T&G profile installed to soffit areas (refer to floor plan)
  • - Wall mber weatherboard 2.23 - Wall Internal R2.27
  • Hermpac ver cal cedar cladding on 20mm cavity system Allow dwangs to be installed as per the cladding
  • 480mm crs for ver cal weatherboard Joinery (External):
  • Hermpac ver cal cedar cladding on 20mm cavity system Underlay(s):
  • Selected weatherboard cladding installed to manufacturers
  • Vertical Shiplap Weatherboard
  • Cavity Fix Vertical Shiplap Weatherboard System NOTES:
  • - All weatherboard fixings pre-drilled maximum 1mm diameter smaller than the nail/screw gauge. - All Hermpac timber products, cut ends and edges to be precoated as per Installation Specifications.
  • - For non-hemmed corner flashings, ensure a minimum 75mm cover to weatherboards beyond the point where BRANZ Bulletin 411 compliant weatherboard lap or rebate combinations terminate at
  • - Prior to installation, refer to Hermpac Vertical Shiplap Technical Installation Specifications. CMNZ30036
  • Cavity Fix Vertical Shiplap Weatherboard System point where BRANZ Bulletin 411 compliant weatherboard lap or rebate combinations terminate at
  • Cavity Fix Vertical Shiplap Weatherboard System - All weatherboard fixings pre-drilled maximum 1mm diameter smaller than the nail/screw gauge.
  • Hermpac VertiLine Vertical Shiplap Installation Specifications. 100 x 100mm Hermpac
  • Vertical cedar weatherboard
  • 2.1 TIMBER WEATHERBOARD 2.2 FIBRE CEMENT SHEET CLADDING
  • 3.5 PRIME OR SEAL TIMBER WEATHERBOARDS 3.6 INSTALL TIMBER WEATHERBOARDS
  • (minimum 2 coats) before fixing weatherboards and exterior trim. Install level, true to line and face, to NZBC E2/AS1, 9.4 Timber weatherboards.

Plans (PDF, 11.7MB)Project Specifications (PDF, 0.4MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.