← Board

17 Lost Burn Road Lake Hawea 9382

Queenstown Lakes · property 167100 · LOT 801 DP 606470 - 0.080100 Ha CT- 1196088

Every consent eDocs lists on this property

Consent Description Applicant Status Status date
BC260900 Building Refused -New Residential Dwelling Cancelled
DB250833 Construction Of A 2 Storey Detached Dwelling. Development Contribution Notice Sent
BC250833 Building Construction Of A 2 Storey Detached Dwelling, Including Amendment 0.1: Detached Dwelling. Work Start Extension 4 Sep 2025
BC250111 Building Alteration To Existing Building - Additional Plumbing And Drainage To Existing Building, Creating A Self Contained Residential Dwelling CCC Issued 30 Apr 2026

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of BC250833 read 18 Nov 2026

Value of work
$834k estimated on the application form, GST included
Designer
Cadence Architectural Design Ltd
adrian@cadence.net.nz
021 184 2285
Engineer
Groove Design
kevin@groovedesign.co
02102280957
Licensed: Design
Adrian Taylor BP018944
Licensed: Design
Dylan Mark Rothman
Licensed: Design
Kevin Spacey
Lodged by
Cadence Architectural Design Ltd (Designer)
adrian@cadence.net.nz
021 184 2285
Applicant
Owner
jamie.blakely@gmail.com
021 182 6039
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • modified timber weatherboards Profile: Vertical Shiplap (115mm cover)
  • modified timber weatherboards Profile: Vertical Shiplap (115mm
  • weatherboard 45-41-001 uPVC triple glazed joinery by Starke
  • timber weatherboards Profile: Vertical Shiplap (115mm cover)
  • weatherboard 53-0-001 13mm standard Gib ceiling lining on Rondo
  • vertical weatherboard Thermory Nordic Pine thermally
  • weatherboard 40 x 10 beveled architraves
  • shiplap weatherboards joinery head flashing extends beyond jamb
  • weatherboards returned into reveal, seal to joinery flange
  • Weathertex weatherboard return seal to joinery flange
  • vertical weatherboard powdercoated aluminium
  • weatherboard returned into opening as jamb liner
  • shiplap weatherboards structurally fixed horizontal
  • ITI TIMSPEC WEATHERTEX HORIZONTAL WEATHERBOARD JAMES HARDIE® SOFFITS
  • 4222WH ITI Timspec Weathertex Horizontal Weatherboard 4239JH James Hardie® Soffits
  • Recommended timber cladding profiles EN 84 Wood preservatives - accelerated aging of treated wood prior to biological
  • 2.2 THERMORY - WEATHERBOARD PROFILE Manufacturer/supplier contact details
  • 15 years For Thermory Weatherboards Provide this warranty on the manufacturer/supplier standard form (if not available then use the
  • for weatherboard cladding profiles. Thermory weatherboard profiles (unless detailed otherwise) to NZS 3617 or BRANZ BU 411.
  • Weatherboards in lengths relevant to profile selection and application, with all unsound and open split knots excluded by cross cut removal prior to fixing into position. Refer to SELECTIONS for
  • Acceptable Solution is limited to the following types of weatherboards and their derivatives: Cadence Architectural Design New Part 2 Storey Dwelling 324938
  • Vertical Standard Shiplap Vertical Standard Board and Batten
  • in line of weather is constant and that boards remain vertical. For vertical shiplap boards, where possible the exposed lap should face away from the prevailing wind.
  • Install level, true to line and face, to NZBC E2/AS1: 9.4 Timber weatherboards. Pilot drill all fixings slightly smaller than gauge of fixing to ensure a snug fit and to minimise risk of moisture entry.
  • 3.13 FIXING - VERTICAL SHIPLAP WEATHERBOARDS 3.14 INSTALL FLASHINGS
  • 4.2 SHIPLAP WEATHERBOARDS - THERMORY NORDIC PINE 4.3 TRIMS - THERMORY NORDIC PINE
  • permitted in any length of weatherboard. Cut board at min 30° angle. Use appropriate adhesive to bond boards together and nail overlapping board only.
  • Ensure weatherboards are set-out to achieve correct overlaps and provide a 2mm expansion gap between lapped boards. Single face fix weatherboards to every fixing point, just clear of the
  • Using a 40mm or 50mm x 2.0mm clinch nail, prior to the next row of Vertical Shiplap boards being fixed alongside (structural cavity battens at maximum 480mm centres) and at a position hard up
  • by driving the clinch nail into the frame so that the clinch head settles flush into the weatherboard's surface. The clinch nail head must not sit proud of the timber surface nor prevent the correct
  • minimum flashing cover to weatherboards is maintained depending on corner option selected. Material compatibility to NZBC E2/AS1, table 21, Compatibility of materials in contact and table
  • Weatherboards and trims Location: as per plan
  • Type/Brand: Thermory Nordic Pine - Shiplap Vertical Cladding Grade: Natur (Sound Tight Knot Grade)
  • 4.7 WEATHERBOARD FIXINGS - STAINLESS STEEL NAILS 4.8 WEATHERBOARD FIXINGS - CLINCH NAILS
  • 4222WH ITI TIMSPEC WEATHERTEX HORIZONTAL WEATHERBOARD 1 GENERAL
  • This section relates to the supply and fixing of ITI Timspec Ltd Weathertex, horizontal weatherboard cladding systems either direct fixed or over a drained cavity.
  • Weathertex Selflok or Primelok weatherboards. All associated cavity battens, flashings, accessories and fixings to complete installation.
  • BRANZ Appraisal 511 (2023) Weathertex Direct Fixed Weatherboard Cladding Systems BRANZ Appraisal 512 (2023) Weathertex Cavity Fixed Weatherboard Cladding Systems
  • Weathertex Construction Detail Guide - Primelok Weatherboards Weathertex Construction Detail Guide - Selflok Weatherboards
  • © CIL Masterspec Jul 2025 4222WH ITI TIMSPEC WEATHERTEX HORIZONTAL WEATHERBOARD Page 60 1.6 QUALIFICATIONS GENERALLY
  • 1.8 COMPLIANCE - WEATHERTEX CAVITY FIXED WEATHERBOARDS 1.9 PERFORMANCE
  • 2.1 WEATHERTEX SELFLOK WEATHERBOARDS 2.2 COVER BOARDS, MOULDINGS AND SCRIBERS
  • For Weathertex Selflok and Primelok weatherboards, factory primed and associated components and accessories.
  • 15 years For Weathertex Selflok weatherboards, natural finish and associated components and accessories.
  • To meet the requirements of BRANZ Appraisal 512 Weathertex Cavity Fixed Weatherboard Cladding Systems:
  • Weathertex Selflok weatherboards comply with AS/NZS 1859.4 for exterior hardboard and tested to AS/NZS 4266. Manufactured from exterior grade, selected Australian hardwood fibres that are
  • Weathertex Selflok weatherboards are 300mm wide x 9.5mm thick x 3660mm long planks either pre-primed or natural finish. Planks are profiled with an interlocking lap joint on the top & bottom
  • © CIL Masterspec Jul 2025 4222WH ITI TIMSPEC WEATHERTEX HORIZONTAL WEATHERBOARD Page 61 2.4 WALL UNDERLAYS
  • 2.10 TRIMTEC ALUMINIUM JOINTERS - FOR SELFLOK WEATHERBOARDS 2.11 TRIMTEC INTERNAL / EXTERNAL CORNER / STOP END TRIMS
  • For Weathertex pre-primed weatherboards with concealed or semi-concealed fixing, use specified hot dip galvanized nails in accordance with Fastening Tables in Weathertex New Zealand
  • For Weathertex Selflok, pre-primed weatherboards with exposed traditional fix fastenings and for Weathertex Selflok, natural finish weatherboards use specified Grade 304 stainless steel nails for
  • 9.1.8.3 Vermin Proofing, for use in conjunction all Weathertex weatherboards. Available in 1830mm lengths.
  • For Primlok weatherboards, can substitute Weathertex Large Cavity Closer & Weathertex Starter Strip for a folded colour coated steel cavity closer strip 29mm wide, to requirements of NZBC
  • Weathertex weatherboards except for Selflok Natural (unprimed) weatherboards. Trimtec anodised aluminium joiner for use in conjunction with Selflok weatherboard profiles only,
  • anodised aluminium for use in conjunction all Weathertex weatherboards, supplied in 3660mm lengths.
  • conjunction with butt and mitre joints to Selflok Natural finish weatherboards. Accessories
  • © CIL Masterspec Jul 2025 4222WH ITI TIMSPEC WEATHERTEX HORIZONTAL WEATHERBOARD Page 62 3 EXECUTION
  • are at maximum 600mm centres (maximum 450mm centres for Primlok Weatherboards in some wind zone classifications).
  • suit weatherboard profile. Application - Weathertex Horizontal Weatherboards
  • © CIL Masterspec Jul 2025 4222WH ITI TIMSPEC WEATHERTEX HORIZONTAL WEATHERBOARD Page 63 3.11 GROUND CLEARANCE - SEAL BOTTOM EDGE & BACK FACE
  • 3.15 FIXING - SELFLOK WEATHERBOARDS 3.16 TRADITIONAL JOINER - SELFLOK PRE-PRIMED WEATHERBOARDS
  • 3.17 TRIMTEC LONG VERTICAL JOINER - SELFLOK PRE-PRIMED / NATURAL WEATHERBOARDS 3.18 INSTALL FLASHINGS
  • 3.19 PAINTING PRE-PRIMED WEATHERBOARDS Installation of Weathertex weatherboards shall be in accordance to the Weathertex New Zealand
  • Installation manual and BRANZ Appraisal 511 for Weathertex Direct Fixed Weatherboard Cladding Systems and BRANZ Appraisal 512 for Weathertex Cavity Fixed Weatherboard Cladding Systems.
  • Ensure Weathertex weatherboards overhang bottom plate on a concrete slab by minimum 50mm. Ensure the bottom edge of Weathertex weatherboards are minimum 100mm clear of paved
  • extend undercoat 100mm up the back face of weatherboard. Reprime all cut edges of Weathertex pre-primed weatherboards with solvent based undercoat. It is
  • If using countersunk screw fixings for pre-primed weatherboards, allow to prime screw holes after screwing. Once holes are filled, the filler should be sanded and area re-primed prior to painting.
  • Weathertex weatherboards. It is recommended that expansion gaps be used for wall lengths greater than 6m to allow for thermal expansion / contraction of aluminium trims.
  • Application - Weathertex Selflok Weatherboards Install level, true to line and face. Commence at wall base, first row to over-hang bottom plate by
  • 50mm, fasten 70mm up from the bottom edge of weatherboard at each stud, a second row of fasteners shall be placed at each stud according to either traditional or semi-concealed fixing
  • pattern as selected. For successive rows of weatherboards rest the rebated edge of Selflok edge on the row below, apply firm pressure to ensure interlocking prior to fastening at each stud
  • second row. Use Weathertex traditional jointer to suit profile / finish of selected weatherboard, fit joiner to an installed plank. Joiners provide a tight fit to the board, if required a hand plain may be
  • Align weatherboard joins to form a single vertical off-stud joint using the Trimtec Long Vertical Joiner. Joiners must be supported by noggings at 800mm centres or alternatively positioned over a
  • NZBC E2/AS1. Ensure minimum flashing cover to weatherboards is maintained. Cadence Architectural Design New Part 2 Storey Dwelling 324938
  • © CIL Masterspec Jul 2025 4222WH ITI TIMSPEC WEATHERTEX HORIZONTAL WEATHERBOARD Page 64 3.20 COMPLETION MATTERS
  • 4.1 WEATHERTEX SELFLOK - HORIZONTAL WEATHERBOARDS, PRE-PRIMED 4.2 NAIL FIXINGS - FOR SELFLOK WEATHERBOARD TO TIMBER FRAMING
  • Ensure Weathertex pre-primed weatherboards are painted with 60 days of installation. Refer to relevant painting section for details.
  • © CIL Masterspec Jul 2025 4222WH ITI TIMSPEC WEATHERTEX HORIZONTAL WEATHERBOARD Page 65 4239JH JAMES HARDIE® SOFFITS

Plans (PDF, 4.7MB)Project Specification (PDF, 1.3MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.

From the documents of BC250111 read 19 Nov 2026

Value of work
$20k estimated on the application form, GST included
Designer
Cadence Architectural Design Ltd
adrian@cadence.net.nz
021 184 2285
Licensed: Design
Adrian Taylor BP108944
Lodged by
Cadence Architectural Design Ltd (Designer)
adrian@cadence.net.nz
021 184 2285
Applicant
Owner
jamie.blakely@gmail.com
021 182 6039
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding