← Board

4 Lauderdale Lane Wanaka 9382

Queenstown Lakes · property 160960 · LOT 525 DP 600652 - 0.160600 Ha CT- 1172058

Every consent eDocs lists on this property

Consent Description Applicant Status Status date
CC260176 John Eley - Connection To Council Services At 4 Lauderdale Lane, Wanaka Assessing Application
BC261463 Building Construction Of Single Storey Dwelling With Attached Garage Waiting for Further Information

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of BC261463 read 18 Nov 2026

Value of work
$863k estimated on the application form, GST included
Lodged by
Peetah Schist
peetah.schist@a1homes.co.nz
03 377 9051
Applicant
Owner
john.p.eley@gmail.com
jzampese@gmail.com
027 266 8928
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • Vertical Hermpac Cedar only: nogs @ 480crs max Scyon Stria OR Oblique Cladding:
  • Selected Herman Pacific Cedar Vertical Shiplap various sized cladding on CAVIBAT battens, installed, flashed and finished to the latest Manufacturers specifications and
  • Vertical Cedar 52.84 m2
  • Fibre cement weatherboard over nominal 20mm drained cavity
  • James Hardie Oblique weatherboard - Vertical Vertical Shiplap Cedar
  • 4 Weatherboards, exterior joinery and 14 – 18 14 – 18 14 – 18 finishing timbers
  • b) For timber weatherboards and exterior joinery, 20% at the time of painting,
  • cedar or redwood, or is treated with copper based ACQ or CuAz preservatives, use type 304 stainless steel or silicon bronze
  • ObliqueTM Weatherboard over flashing tape, carefully cut to
  • 28 Oblique™ Weatherboard Vertical Installation Technical Specification | October 2022 100
  • Oblique™ Weatherboard fixed vertically
  • Oblique™ Weatherboard 14mm - Vertical FOUNDATION DETAIL OPTION 1
  • 300mm weatherboard width EH wind zone and SED James Hardie Linea™
  • Weatherboard Vertical Installation Technical Specification July 2018 New Zealand 21 aluminium box corner
  • James Hardie Linea™ Oblique™
  • Weatherboard Vertical Installation Technical Specification July 2018 New Zealand 17 Figure 4: Soffit detail
  • Vertical Shiplap Weatherboard
  • 20 James Hardie Linea™ Oblique™
  • Weatherboard Vertical Installation Technical Specification July 2018 Figure 10: Internal corner
  • OBLIQUE/CEDAR INTERNAL CORNER Rigid wall underlays shall (required in Extra High wind zones):
  • battens & weatherboards to be fixed to. T scale off drawings. Cross reference all drawings. Any discrepancies MUST be clarified
  • 0mm weatherboard width EH wind zone and SED James Hardie Linea™
  • Weatherboard Vertical Installation Technical Specification July 2018 New Zealand 21 minium box corner
  • battens & weatherboards to be fixed to. Figure 11: External aluminium box corner
  • VERTICAL OBLIQUE/CEDAR EXT 36 Oblique™
  • Weatherboard Vertical Installation Technical Specification | March 2026 Figure 13: Soffit detail
  • Oblique™ Weatherboard finished with selected coating
  • Oblique™ Weatherboard must be neat cut and silicone
  • Oblique™ Weatherboard - Vertical Timber Cavity Batten with Flexible Underlay
  • Weatherboard Vertical Installation Technical Specification | March 2026 New Zealand 35 Flexible underlay
  • Weatherboard in internal corner
  • Weatherboard Vertical Installation Technical Specification | March 2026 New Zealand 33 40 mm
  • ObliqueTM Weatherboard to butt into the Hardie™ 14mm
  • oint 300mm weatherboard width EH wind zone and SED nal aluminium box corner
  • Figure 9: Vertical joint 300mm weatherboard width EH wind zone and SED Figure 10: Internal corner
  • Figure 9: Vertical joint 300mm weatherboard width EH wind zone and SED OBLIQUE EXTERNAL CORNER
  • t 300mm weatherboard width EH wind zone and SED aluminium box corner
  • VERTICAL OBLIQUE/CEDAR DO NOT scale off drawings. Cross reference all drawings. Any discrepancies MUST be clarified
  • Weatherboard Vertical Installation Technical Specification July 2018 l corner
  • oint 300mm weatherboard width EH wind zone and SED James Hardie Linea™
  • Weatherboard Vertical Installation Technical Specification July 2018 New Zealand 21 nal aluminium box corner
  • battens & weatherboards to be fixed to. O NOT scale off drawings. Cross reference all drawings. Any discrepancies MUST be clarified
  • Weatherboard Vertical Installation Technical Specification July 2018 orner
  • t 300mm weatherboard width EH wind zone and SED James Hardie Linea™
  • VERTICAL OBLIQUE/CEDAR VERTICAL OBLIQUE SOFFIT DETAIL
  • Weatherboard Vertical Installation Technical Specification | March 2026 New Zealand 41 35mm
  • Weatherboard Vertical Installation Technical Specification | March 2026 New Zealand 39 Air seal as per E2/AS1
  • Weatherboard 8 mm gap nominal
  • Weatherboard Vertical Installation Technical Specification | March 2026 Figure 15: Window sill
  • Your detail: Figure 13-14-15 - Linea Oblique Vertical http://wksp.nz/jh-lio-vwin
  • Weatherboard Vertical Installation Technical Specification | March 2026 Figure 39: Garage door head
  • Weatherboard Vertical Installation Technical Specification | March 2026 New Zealand 63 Figure 40: Garage door jamb
  • Rusticated Weatherboard Flexible flashing tape
  • Cedar Weatherhead if required
  • Cavity Fix Rusticated Weatherboard System CMNZ30037
  • Rusticated Weatherboard Line of head flashing over
  • Cavity Fix Rusticated Weatherboard System Notes:
  • - All weatherboard fixings pre-drilled maximum 1mm diameter smaller than the nail/screw gauge. - All Hermpac timber products, cut ends and edges to be precoated as per Installation Specifications.
  • - For non-hemmed corner flashings, ensure a minimum 75mm cover to weatherboards beyond the point where BRANZ Bulletin 411 compliant weatherboard lap or rebate combinations terminate at
  • - Prior to installation, refer to Hermpac Rusticated, Splaycut & Multi-Splay Technical Installation Specifications.
  • CEDAR JOINERY HEAD DETAIL CEDAR JOINERY JAMB DETAIL DO NOT scale off drawings. Cross reference all drawings. Any discrepancies MUST be clarified
  • HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING
  • 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM This section relates to the supply and fixing of Hermpac Vertical cladding:
  • Vertical Shiplap weatherboards Board and Batten weatherboards
  • Vertical Shiplap 'Vertibat' cavity batten systems 1.1 ABBREVIATIONS AND DEFINITIONS
  • NZS 3617 Profiles of weatherboards, fascia boards and flooring JAS-ANZ CodeMark Certification CMNZ30036 - Hermpac VertiLine Vertical Shiplap Weatherboard
  • Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System installation Specifications Hermpac Vertical Shiplap Weatherboard Direct Fix System Installation Specifications
  • Hermpac Product Technical Statement (PTS) – VertiLine Vertical Shiplap Weatherboard Cavity System (July 2023)
  • Hermpac Product Installation Checklist – VertiLine Vertical Shiplap Weatherboard Cavity System (Jan 2023 V2)
  • Hermpac Board and Batten Weatherboard Cavity System Installation Specifications Hermpac Board and Batten Weatherboard Direct Fix System Installation Specifications
  • Hermpac Product Technical Statement (PTS) – Board and Batten Weatherboard Cavity System (July 2023)
  • Hermpac Product Installation Checklist – Board and Batten Weatherboard Cavity System (Jan 2023 V2)
  • Hermpac WR & Yellow Cedar cuts and characteristics iDesign Architecture Eley & Zampese 361123
  • © CIL Masterspec Sep 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 64 of 151 2 PRODUCTS
  • BRANZ Appraisal 650 - Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System Manufacturer/supplier contact details:
  • 5 years For installation of Hermpac vertical weatherboard cladding systems Provide this warranty on the installer/applicator standard form (if not available then use the
  • Hermpac vertical weatherboard cladding systems meet the requirements of the NZBC when used within the Conditions and Limitations of their Certificate CMNZ30036.
  • 2.1 VERTICAL SHIPLAP / VERTICAL BOARD AND BATTEN Weatherboards to Hermpac profiles, Lap and Rebate details to BRANZ BU 411 and general design
  • wood-based building components to achieve a 15-year durability performance. Weatherboards in lengths relevant to profile selection and application, with all unsound and open split knots excluded
  • © CIL Masterspec Sep 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 65 of 151 Acceptable Solution is limited to the following types of weatherboards and their derivatives:
  • Vertical Standard Shiplap and Hermpac Custom Profiles Vertical Standard Board and Batten and Hermpac Custom Profiles
  • A selection of the above profiles are also available in Western Red Cedar and Yellow Cedar finger-joint (CedarOne Evolve and CedarLine Evolve). CedarOne Evolve is quarter-sawn cut Cedar.
  • CedarLine Evolve is primarily flat-sawn cut Cedar. Evolve profiles are available across most standard and custom profiles. The timber is machined with a “combed” finish to the front face and
  • Western Red Cedar and Yellow Cedar. Profiles are machined with a “dressed” finish to the front face and the exposed corners are machined to paint quality - PQ (ie. rounded edges for paint
  • © CIL Masterspec Sep 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 66 of 151 3 EXECUTION
  • relative to visible edge of board. For vertical shiplap boards, where possible the exposed lap should face away from the prevailing wind.
  • Hermpac Western Red Cedar, Yellow Cedar or DuraLarch™ weatherboards fixed with Stainless Steel or Silicon Bronze Hermpac Crown, Rose and Flat Head nails or Hermpac Starcap screws and
  • Kanda weatherboards fixed with Hermpac Starcap screws are limited to use in NZS 3604 Wind Zones up to and including Extra High when dwangs or structurally fixed Vertibat cavity battens are
  • © CIL Masterspec Sep 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 67 of 151 4 SELECTIONS
  • Hermpac Western Red Cedar weatherboards fixed with stainless steel jolt head nails are limited to use in NZS 3604 Wind Zones up to and including Medium when dwangs or structurally fixed Vertibat
  • Hermpac Yellow Cedar and DuraLarch™ weatherboards fixed with jolt head nails are limited to use in NZS 3604 Wind Zones up to and including Extra High when dwangs or structurally fixed Vertibat
  • 3.9 FIXING VERTICAL SHIPLAP WEATHERBOARDS Install level, true to line and face, to NZBC E2/AS1: 9.4 Timber weatherboards. Single face fix
  • weatherboards to every fixing point, clear of the adjacent lapped board. Fixing to be driven in with a slightly upward slope. Line fixings horizontally across the boards. Pilot drill all fixings slightly
  • Hermpac Construction Drawings for accurate weatherboard fixing information. Using a Hermpac specialty clinch nail, prior to the next row of Vertical Shiplap boards being fixed
  • clinch nail into the cavity batten so that the clinch head settles flush into the weatherboard's surface. The clinch nail head must not sit proud of the timber surface nor prevent the correct separation of
  • each adjacent row of boards. Do not pin laps or weatherboard faces. Refer to Hermpac Construction Drawings and Installation Specification for suitable face fixings
  • Kanda weatherboards must be fixed with Hermpac Starcap screws), correct placement of fixings, size, length and minimum penetration requirements, and for external and internal corner
  • Coated weatherboards laid over Mill Finish Grade 316 Stainless Steel: Sika: Wipe weatherboard surfaces with a clean rag. Using an abrasive pad, rub down Stainless
  • Steel in a single pass before cleaning with Sika Aktivator-205. Coat both weatherboards and Stainless Steel with Sika Primer 3N and apply a continuous 5mm bead of Sikaflex-11FC or Sikaflex
  • Soudal: Wipe weatherboard surfaces with a clean rag before wiping Stainless Steel only with Gorilla 696 Surface Activator, being careful not to coat any powder coated surfaces. Apply a minimum
  • © CIL Masterspec Sep 2026 4221HV HERMPAC VERTICAL WEATHERBOARD CLADDING SYSTEM | Page 68 of 151 1 GENERAL
  • 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING This section relates to the supply and fixing of Oblique™ Weatherboard cladding.
  • Oblique™ Weatherboard by James Hardie® Cavity Cladding System
  • Oblique™ Weatherboard Horizontal Installation Technical Specification (March 2026) Oblique™ Weatherboard Vertical Installation Technical Specification (March 2026)
  • Oblique™ Weatherboard Vertical Installation to Hardie™ 40mm Structural Horizontal Cavity Batten Technical Specification (March 2026)
  • BRANZ Appraisal 1231 (2022) - Oblique™ Weatherboard (Horizontal) Cavity Cladding - amended 31 March 2026
  • BRANZ Appraisal 1232 (2022) - Oblique™ Weatherboard (Vertical) Cavity Cladding - amended 31 March 2026
  • 25 years For Oblique™ Weatherboard products (refer to James Hardie® product warranty)
  • © CIL Masterspec Sep 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 69 of 151 2 PRODUCTS
  • Oblique™ Weatherboard Care and Maintenance guide. Provide this information prior to practical completion.
  • 1.9 OBLIQUE™ WEATHERBOARD INSTALLATION CHECKLIST Installer to complete, sign and provide a James Hardie® Installation Checklist.
  • James Hardie® Oblique™ Weatherboard meets the requirements of the NZBC when used within the Conditions and Limitations of its Certificate of conformity CMNZ30147.
  • James Hardie® Oblique™ Weatherboard cladding tested to AS/NZS 3837 and to specific requirements of C/AS1 or C/AS2 achieving Type A classification (peak heat release rate ≤ 100
  • 2.1 OBLIQUE™ WEATHERBOARDS Oblique™ Weatherboards, rusticated profile, 14mm thick, available in 200mm or 300mm widths and
  • © CIL Masterspec Sep 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 70 of 151 2.2 RIGID AIR BARRIERS
  • Aluminium moulding used beside window opening to end butt the Oblique™ Weatherboard. 2.8 HARDIE™ 14MM ALUMINIUM TRIMLINE JOINT FLASHING
  • 2.11 WEATHERBOARD INTERNAL "W" CORNER Anodised aluminium extrusion to flash behind cladding at internal corners.
  • Oblique™ Weatherboards over cavity battens over flexible underlay. 2.16 GRADE 316 STAINLESS STEEL NAILS
  • fixing Oblique™ Weatherboards over cavity battens over flexible underlay. 2.17 HOT DIPPED GALVANIZED NAILS
  • Oblique™ Weatherboards over battens over rigid air barrier. iDesign Architecture Eley & Zampese 361123
  • © CIL Masterspec Sep 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 71 of 151 3 EXECUTION
  • Oblique™ Weatherboards over battens over rigid air barrier. 2.19 FLEXIBLE SEALANT
  • weatherboards are fixed. Application - particular installations
  • 3.5 INSTALL CAVITY BATTENS - OBLIQUE™ HORIZONTAL WEATHERBOARDS Install 20mm minimum thick cavity battens to NZBC E2/AS1, 9.0 Wall claddings, where required.
  • 3.6 INSTALL CAVITY BATTENS - OBLIQUE™ VERTICAL WEATHERBOARDS Install 20mm thick Hardie™ Horizontal Cavity Battens. Fix horizontal cavity battens to wall framing
  • © CIL Masterspec Sep 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 72 of 151 4 SELECTIONS
  • 3.8 INSTALL OBLIQUE™ WEATHERBOARDS - HORIZONTAL INSTALLATION Cut weatherboards to required lengths for vertical jointing. Prime site cut ends that are exposed
  • prior to installation. Fit vertical jointers, internal and external corners and fix weatherboards as per Oblique™ Weatherboard Horizontal technical specifications.
  • 3.9 INSTALL OBLIQUE™ WEATHERBOARDS - VERTICAL INSTALLATION Cut weatherboards to required lengths. Prime site cut ends that are exposed prior to installation.
  • Fit joint flashing, internal corners and external corners and fix weatherboards as per Oblique™ Weatherboard Vertical technical specifications.
  • © CIL Masterspec Sep 2026 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING | Page 73 of 151 1 GENERAL

Plans (PDF, 8.2MB)Project Specification (PDF, 1.7MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.