← Board

47 Carrickmore Crescent Wanaka 9382

Queenstown Lakes · property 160770 · LOT 493 DP 600652 - 0.121400 Ha CT- 1172039

Every consent eDocs lists on this property

Consent Description Applicant Status Status date
RM260066 Resource Application To Construct A Residential Unit Breaching Height And Associated Earthworks (Within Activity Area C1 Of The Nl Special Zone) At 47 Carrickmore Crescent, Wanaka C & S Bruce, S Clarke & Webb Farry Trustees 2014 Limited Decision Issued 12 Mar 2026
BC260325 Building New 2 Storey Dwelling With Attached Garage On Hold at Applicants Request

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of RM260066 read 19 Nov 2026

Lodged by
Not named on the application form
Timber cladding
  • • Vertical cedar weatherboard with oil finish “Dryden’s Elm” • Sliding screens – Cedar with stain finish “Flaxpod” (7% LRV)
  • SOFFITS - SHIPLAP RK TIMBERS SHIPLAP CLADDING SYSTEM, STAINED VERTICAL
  • WESTERN RED CEDAR RK55 PROFILE (110MM COVER BOARDS - 6MM NEGATIVE) FIXED VIA 60MMX12G ASSY S/S SCREWS
  • TIMBER CLADDING RK TIMBERS SHIPLAP CLADDING SYSTEM, STAINED VERTICAL
  • WESTERN RED CEDAR RK55 PROFILE (110MM COVER BOARDS - 6MM NEGATIVE) FIXED OVER 20MM H3.2 HORIZONTAL

Updated AEE - 05.02.26 (PDF, 5.4MB)Updated Plans - 09.02.26 (PDF, 16.7MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.

From the documents of BC260325 read 18 Nov 2026

Value of work
$1.5m estimated on the application form, GST included
Designer
Threefold Architecture - Bryce Monk
bryce@threefoldarchitecture.co.nz
027 425 0644
Engineer
Engco - Julian Addington
julian@engco.co.nz
021 240 0877
Builder
Bespoke Builds Ltd. - Jason
jason@bespokebuilds.co.nz
027 4063856
Licensed: Design
Bryce Monk
Lodged by
Not named on the application form
james@threefoldarchitecture.co.nz
027 252 9331
Applicant
Owner
suejlmclarke@xtra.co.nz
021 729287
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • Rosenfeld Kidson & Co Cedarscreen Weatherboard Systems ...............................................................................44 Thermakraft Underlay, DPM, DPC & Tapes............................................................................................................48
  • 3617:1979(NZS) Specification for profiles of weatherboards, fascia boards, and flooring 3622:2004(NZS) Verification of timber properties
  • 6.9 Rosenfeld Kidson & Co Cedarscreen Weatherboard Systems 6.9.1 Scope
  • 6.9.1.1 Cedarscreen Vertical Shiplap Weatherboard - 20mm Cavity Supply and install the RK TIMBERS (Ex Rosenfeld Kidson) Cedarscreen Vertical Shiplap Weatherboard 20mm Cavity System, as
  • The Rosenfeld Kidson Cedarscreen Vertical Shiplap Weatherboard 20mm Cavity System is CodeMark assured: CodeMark Product Certificate No. CM70083, issued by Bureau Veritas Australia Pty Ltd.
  • No substitutions or deletions are permitted for the Rosenfeld Kidson Cedarscreen Vertical Shiplap Weatherboard 20mm Cavity System.
  • 6.9.2.1 Western Red Cedar, Premium Clears No 1 – Vertical Shiplap Weatherboard Rosenfeld Kidson Vertical Shiplap Weatherboard Premium Grade PC1 Clears shall be manufactured from sustainably sourced
  • Canadian Western Red Cedar (Thuja plicata). Producers carry SFI, CSA, FSC or PEFC Certifications. Western Red Cedar used above ground complies with New Zealand Building Code Clause B2 Durability, Performance Requirement
  • 6.9.3 Weatherboard Profile 6.9.3.1 RK55 Vertical Shiplap
  • RK55 Rosenfeld Kidson Vertical Shiplap Weatherboard: 110mm effective cover, 135mm wide x 18.5mm thick. Installed Location:
  • 6.9.4 Weatherboard Finish & Coating 6.9.4.1 Bandsawn Face - Dryden WoodOil Clear Finish - Western Red Cedar
  • Cedarscreen Western Red Cedar weatherboard profiles and timber mouldings shall be shall be manufactured with a Bandsawn Face (BSF) and supplied factory-coated with Dryden WoodOil applied to all faces and edges.
  • All site-cut ends, notches and holes in weatherboards and timber mouldings must be sealed with one coat of Dryden WoodOil Following installation, Cedarscreen Western Red Cedar weatherboards and timber mouldings shall be coated with a finishing coat of
  • 6.9.5.1 Timber Cavity Battens, 20mm Cavity - Vertical Weatherboard Timber Cavity Battens (non-structural) to form a nominal 20mm deep drained cavity for vertical weatherboards.
  • accordance with the applicable Cedarscreen Weatherboard Cladding Manual(s) 6.9.8 Co-operation
  • barriers, and trims and any other related works are completed in accordance with the Cedarscreen Weatherboard Cladding System technical manuals and approved construction drawings.
  • Cedarscreen weatherboards. Coordinate with trades the locations of pipes, outlets, cables, meter boards and other fittings installed by others, and to install
  • Cedarscreen Weatherboard Cladding System as required. 6.9.9 Workmanship
  • required construction and installation techniques, in accordance with applicable Cedarscreen Weatherboard Cladding Manual(s) and to fully comply with all warranty requirements.
  • Store Cedarscreen weatherboards and accessories undercover, flat and true, clear of the ground by at least 100mm and supported on dry and clean timber in accordance with Rosenfeld Kidson & Co recommendations. Keep stored weatherboards and accessories dry
  • Do not use damaged or defective weatherboards or accessories. Should a problem be encountered with any Rosenfeld Kidson & Co product, immediately contact Rosenfeld Kidson & Co on 09 573 0503 (North Island) or 03 349 3316 (South Island). Do not continue
  • Handle weatherboards in accordance with the manufacturer's recommendations and in a manner that prevents damage and surface marking.
  • 6.9.11.1 Cavity Fix over Flexible Underlay - 20mm Cavity, Vertical Weatherboard Cedarscreen Shiplap Weatherboard Cladding - installed over bevelled and castellated Cavity Batten profiles with a Flexible Wall
  • Install Cedarscreen Weatherboard Cladding, complete with all system components and accessories required for proper installation and performance, in accordance with the appropriate Cedarscreen Cladding System Manual and as shown on the approved
  • Ensure that all site-cuts to weatherboards and timber mouldings are properly sealed with Dryden WoodOil accordance with WoodOil application requirements
  • All internal and external weatherboard corner junctions, inter-storey junctions, and weatherboard trim and accessories, shall be constructed and installed to the details shown on the drawings and Cedarscreen technical resources.
  • - The layout of the vertical shiplap weatherboards should be configured against the prevailing wind. - Establish an accurate measurement between the starting corner and finishing point, working out an even board set out taking into
  • - Jamb to head and sill junctions – ensure weatherboards are full width and continuous in length. - Ensure vertical weatherboards are continuous in length between inter storey heights (maximum height 2 storey).
  • - Check weatherboard length spread and use appropriately to suit each cladding face. 6.9.13 Fixing
  • 6.9.13.1 Fixing - Vertical Weatherboard, Stainless Steel Fix Cedarscreen Weatherboards with Rose Head, Annular Grooved, Grade 316 Stainless Steel Nails in accordance with Cedarscreen
  • All nail fixings shall be pre-drilled slightly smaller than the nail gauge. Do not brad weatherboards prior to face nailing. Single fix rusticated weatherboards at every fixing point, located 35-40mm up from the bottom or lapped edge of the weatherboard,
  • Ensure the weatherboards are set-out with an overlap of 25mm, with a 2mm expansion gap between boards at the overlap. Set rose head nails flush onto the board surface - not into or below the surface.
  • Check that the CedarscrenWeatherboard Cladding system has been correctly installed and fixed to the layout and details shown on the drawings and in accordance with the requirements of the applicable Cedarscreen Cladding Manual(s)
  • weatherboard cladding system is weathertight. Check for damage and defects - replace or repair as necessary to the required standard.

Project Specifications (PDF, 0.9MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.