12 Kahiwi Drive Lower Shotover 9304
Queenstown Lakes · property 148510 · LOT 6 DP 568849 - 0.200000 Ha CT- 1023833
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| RM261017 Resource | S88 Application For The Construction Of A Residential Unit Including A Retaining Wall, With Breaches To Road Boundary Setback Distance And Earthworks Standards S221 Application To Vary Cn Regarding The Provision Of A Buffering Tank And Booster Pump At 12 Kahiwi Drive, Lower Shotover, Queenstown | R & P Wood | Waiting for Further Information | |
| BC261390 Building | Construction Of New Single Level Dwelling With Attached Garage | Building Consent Issued | 2 Nov 2026 |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of RM261017 read 18 Nov 2026
- Lodged by
- Amanda Leith; Remarkable Planning Limited
amanda@remarkableplanning.nz
021621759 - Applicant
- R & P Wood
r.pinnock@hotmail.com
accounts@maebellehomes.co.nz
0226584096
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
-
- Selected Vertical Cedar Cladding on 20mm cavity battens system
- BBS Vertical Cedar Cladding with a 20mm cavity
- Vertical Cedar Cladding on 20mm cavity battens system as per manufacturers specifications.
- - VERTICAL CEDAR CLADDING - RESENE WATERBORNE PITCH BLACK - SCHIST CLADDING - BAGGED SCHIST
- Cedar Clad garage door 40mm Schist Veneer on 9mm backing board on
- Selected Vertical Cedar Cladding on 20mm cavity
- Cedar Cladding - Dwangs @ 400crs Kitchen
- Selected Vertical Cedar Cladding on 20mm cavity battens system.
- Cedar Cladding - Dwangs @ 400crs Master Bedroom
- Cedar Cladding - Dwangs @ 400crs 40° pitch Corrugated profile roofing on self supporting
- Cedar Base Detail NTS
- Shiplap Soffit Detail NTS
- Cedar to Corrugated Cladding External Corner Detail Scale 1:5
- min cover behind Cedar cladding.
- and Cedar cladding Corrugated metal Vertical
- Schist to Cedar Internal Corner Detail Scale 1:5
- & Cedar cladding 0.55BMT metal flashing with
- behind Schist & Cedar cladding RigidRap barrier, flexible
- Vertical Cedar cladding on 20mm cavity battens system
- Cedar Window Sill Detail NTS
- Cedar Window Jamb Detail NTS
- Cedar Window Head Detail NTS
- Cedar Cladding Horizontal Joint Detail NTS Schist Cladding Inter-Story Control Joint Detail
- Pipe Penetration through Cedar Cladding NTS
- Selected Cedar cladding on 20mm Cavity system
- Cedar Clad garage door
Appendix D - Proposed plans (PDF, 13.0MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.
From the documents of BC261390 read 18 Nov 2026
- Value of work
- $1.5m estimated on the application form, GST included
- Designer
- Jayant Rata
jayantrana@hotmail.com
0226348007 - Engineer
- Julian Addington
tim@engoco.co.nz
027 531 0741 - Builder
- Andrew Sorbello
projectbuiltltd@gmail.com
0220261137 - Lodged by
- Tim Baty (Builder)
tim@maebellehomes.co.nz
accounts@maebellehomes.co.nz
021 029 46929 - Applicant
- Owner
pauldw996@gmail.com
021 222 4582
As written on the application form. Don't add applicants to email marketing lists: that needs their consent. - Timber cladding
- Not mentioned in the documents read