← Board

52 Hansen Road Frankton 9300

Queenstown Lakes · property 135460 · Title updated from: 860237

Every consent eDocs lists on this property

Consent Description Applicant Status Status date
RM260853 Resource Land Use Consent Is Sought To Establish A Commercial Development Comprising 49 Dualkey Commercial Units 98 Tenancies, With Breaches To Zoning, Built Form, Transport, Earthworks And Signage Breaches At 52 Hansen Road, Frankton, Queenstown Hansenqt Limited On Hold External Report Required
DE260780 Estimate Only_X000d_ Hansenqt Limited - A Fee-Simple Subdivision At The Site, To Enable Each Lot To Become A Free Hold Title And To Enable The Future Development Of The Bottom Terrace Of The Site Proposed Lot 602. Application Also Seeks To Provide For 38 Units To Be Available For Rva Each Unit With A Cumulative Total Of 180 Nights Per Annum Per Unit At 52 Hansen Road, Frankton, Queenstown Development Contribution Required
BC260567 Building 14 X 1 Bedroom A Frame Type 1 - Units 1-14 - Stage 5 Building Consent Issued 19 Jun 2026
BC260566 Building Stage 3E 10 Units, Units 7382. Originally 47 X 1 Bedroom A Frame & 7X Two Storey, 3 Bedroom Units 29 82 Stage 3. Units 2950 Split To Bc2612520. Units 5172 Split To Bc261521. Building Consent Issued 19 Jun 2026
RN250028 Hansenqt Limited Road Naming Application For New Private Right Of Way Road Called Tomkies Crescent, Located Off Hansen Road, Frankton, Queenstown Decision Issued
RM250965 Resource A Fee-Simple Subdivision At The Site, To Enable Each Lot To Become A Free Hold Title And To Enable The Future Development Of The Bottom Terrace Of The Site Proposed Lot 602. Application Also Seeks To Provide For 38 Units To Be Available For Rva Each Unit With A Cumulative Total Of 180 Nights Per Annum Per Unit At 52 Hansen Road, Frankton, Queenstown Hansenqt Limited Decision Issued 5 Mar 2026
RM250258 Resource Application Under Section 88 Of The Resource Management Act 1991 (Rma) For Land Use Consent For The Establishment Of 100 Residential Units Breaching The Total Number Of Units On Site And Overall Site Density, Maximum Height Standards, Development Not In Accordance With The Frankton North Structure Plan, Buildings In The Business Mixed Use Zone, Residential Activity In The Rural Zone Not Otherwise Provided For, Associated Earthworks (Breaching Maximum Volume, Height Of Fill, Hansen Qt Limited Decision Issued 7 Nov 2025
MN250965 Hansenqt Limited - A Fee-Simple Subdivision At The Site, To Enable Each Lot To Become A Free Hold Title And To Enable The Future Development Of The Bottom Terrace Of The Site Proposed Lot 602. Application Also Seeks To Provide For 38 Units To Be Available For Rva Each Unit With A Cumulative Total Of 180 Nights Per Annum Per Unit At 52 Hansen Road, Frankton, Queenstown Awaiting Officer Review
MN250258 Hansen Qt Limited Application Under Section 88 Of The Resource Management Act 1991 Rma For Land Use Consent For The Establishment Of 100 Residential Units Breaching The Total Number Of Units On Site And Overall Site Density, Maximum Height Standards, Development Not In Accordance With The Frankton North Structure Plan, Buildings In The Business Mixed Use Zone, Residential Activity In The Rural Zone Not Otherwise Provided For, Associated Earthworks Breaching Maximum Volume, Height Of Fill, And Awaiting Monitoring Inspection
EA250258 Hansen Qt Limited - Partial Engineering Acceptance In Relation To Land Use Consent For The Establishment Of 100 Residential Units, Residential Visitor Accommodation And Associated Earthworks, Roading And Infrastructure At 52 Hansen Road, Frankton, Queenstown Decision Issued
DR250965 Hansenqt Limited Development Contribution Required
DB251606 Stage 2 - 18 X Type 1 A Frame (Units 83-100) Development Contribution Required
DB251487 Crest Chalets - Stage 4 - 14 X 1 Bedroom Single Level New Builds (Units 15 - 28) Development Contribution Required
CC250143 Hansen Qt Limited - Connection For Temporary Connection At 52 Hansen Road, Queenstown Approved
BC251610 Building Stage 5 - Construction Of 14 X Two Storey Dwelling (Units 1-14) Rejected - No Information Provided
BC251608 Building Stage 3 - 47 X Type 1 A Frame & 7X Type 3 Two Storey (Units 29-82) Rejected - No Information Provided
BC251606 Building Stage 2 - 18 X Type 1 A Frame (Units 83-100). Including Amendment 01 - Stage 2 Units 83-100 Minor Cladding And Foundation Changes To Original Bc Building Consent Issued 19 Jan 2026
BC251487 Building Crest Chalets - Stage 4 - 14 X 1 Bedroom Single Level New Builds (Units 15 - 28). Including Amendment 0.1 - Stage 4 Units 15-28 Minor Cladding And Foundation Changes To Original Bc Building Consent Issued 19 Jan 2026

Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.

From the documents of RM250965 read 19 Nov 2026

Lodged by
Rose Selby, Barker & Associates
roses@barker.co.nz
0272266673
Applicant
Hansenqt Limited
dillon@gibbonsco.co.nz
021 597 631
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
Not mentioned in the documents read
Not read
no plans

From the documents of BC251610 read 18 Nov 2026

Value of work
$1.7m estimated on the application form, GST included
Designer
DGSE Architects
e.macann@dgse.co.nz
0274282082
Engineer
Jensen McArley & Associates (JMA)
james@jma.co.nz
0277027215
Licensed: Design
Nigel Dong
Licensed: Design
James Jensen
Lodged by
Dillon Towers (Employee - Development manager)
dillon@gibbonsco.co.nz
021597631
Applicant
Owner
kurt@kurtgibbons.co.nz
021998888
As written on the application form. Don't add applicants to email marketing lists: that needs their consent.
Timber cladding
  • JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING JAMES HARDIE® SOFFITS
  • 4231HO James Hardie® Oblique™ Weatherboard Cladding 4239JH James Hardie® Soffits
  • James Hardie Axon™ Panel, face primed shiplap jointed panels, 9.0mm and 8.5mm thick, manufactured from cellulose fibre reinforced cement to AS/NZS 2908.2. Refer to SELECTIONS.
  • Avoid distortion and contact with potentially damaging shiplap edges and surfaces. Do not drag panels across each other, or across other materials. Protect edges, corner and surface finish from
  • 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING 1 GENERAL
  • This section relates to the supply and fixing of Oblique™ Weatherboard cladding. Refer to ~ for ~
  • Oblique™ Weatherboard by James Hardie® Manufacturer and supplier documents relating to this part of the work:
  • Oblique™ Weatherboard Horizontal Installation Technical Specification (June 2024) Oblique™ Weatherboard Vertical Installation Technical Specification (June 2024)
  • Oblique™ Weatherboard Vertical Installation to Hardie™ 40mm Structural Horizontal Cavity Batten Technical Specification
  • BRANZ Appraisal 1231 - Oblique™ Weatherboard (Horizontal) Cavity Cladding BRANZ Appraisal 1232 - Oblique™ Weatherboard (Vertical) Cavity Cladding
  • 25 years For Oblique™ Weatherboard products (refer to James Hardie® product warranty)
  • © CIL Masterspec Dec 2025 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING Page 63 1.6 QUALIFICATIONS GENERALLY
  • 1.10 OBLIQUE™ WEATHERBOARD INSTALLATION CHECKLIST 1.11 CODEMARK CERTIFICATE
  • 2.1 OBLIQUE™ WEATHERBOARDS 2.2 WALL UNDERLAY
  • Oblique™ Weatherboard Care and Maintenance guide. Provide this information prior to practical completion.
  • James Hardie® Oblique™ Weatherboard meets the requirements of the NZBC when used within the Conditions and Limitations of its Certificate of conformity CMNZ30147.
  • James Hardie® Oblique™ Weatherboard cladding tested toAS/NZS 3837 and to specific requirements of C/AS1 or C/AS2 achieving Type A classification (peak heat release rate ≤ 100
  • Oblique™ Weatherboards, rusticated profile, 14mm thick, available in 200mm or 300mm widths and 3000mm or 4200mm lengths, pre-primed, manufactured to AS/NZS 2908.2 from a reduced density
  • © CIL Masterspec Dec 2025 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING Page 64 2.4 20MM VENT STRIP/VERMIN-PROOFING
  • Aluminium moulding used beside window opening to end butt the Oblique™ Weatherboard. Aluminium flashing extrusion used behind cladding joints.
  • Oblique™ Weatherboards over cavity battens over flexible underlay. Bostik® Seal N Flex-1™ or Sikaflex® AT Facade or Sikaflex® MS sealants.
  • © CIL Masterspec Dec 2025 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING Page 65 3.3 PRE-INSTALLATION REQUIREMENTS
  • 3.5 INSTALL CAVITY BATTENS - OBLIQUE™ VERTICAL WEATHERBOARDS 3.6 PENETRATIONS AND FLASHINGS
  • 3.7 INSTALL OBLIQUE™ WEATHERBOARDS - VERTICAL INSTALLATION 3.8 COMPLETION MATTERS
  • 4.1 JAMES HARDIE® OBLIQUE™ WEATHERBOARDS Refer to 1250 TEMPORARY WORKS & SERVICES for protection requirements.
  • weatherboards are fixed. Application - particular installations
  • Cut weatherboards to required lengths. Prime site cut ends that are exposed prior to installation. Fit joint flashing, internal corners and external corners and fix weatherboards as per Oblique™
  • Weatherboard Vertical technical specifications. Completion & Commissioning
  • Type/Brand: Oblique™ Weatherboards Thickness: 14mm
  • © CIL Masterspec Dec 2025 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING Page 66 4.2 HARDIE™ 20MM HORIZONTAL CAVITY BATTEN - FOR VERTICAL INSTALLATION
  • © CIL Masterspec Dec 2025 4231HO JAMES HARDIE® OBLIQUE™ WEATHERBOARD CLADDING Page 67 4239JH JAMES HARDIE® SOFFITS
  • Bevelback weatherboard cladding profile Rusticated weatherboard cladding profile
  • Metalcraft Roofing Bevelback Weatherboard product literature Designgroup Stapleton Elliott Crest Chalets
  • 4.3 TIMBER / WEATHERBOARD - PAINT 4.4 CONCRETE / FIBRE CEMENT / CEMENT PLASTER

Project Specifications (PDF, 0.9MB)

Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.

Not read
plans: Plans - Architectural is 170MB, over the 60MB limit