5 Walter Place Glenorchy 9372
Queenstown Lakes · property 127380 · LOT 56 DP 560508 HAVING 1/6SH IN LOT 101 DP 560508 CT- 98929 2
Every consent eDocs lists on this property
| Consent | Description | Applicant | Status | Status date |
|---|---|---|---|---|
| BC261528 Building | Construction Of A Single Storey Dwelling With Attached Double Carport. | Application Complete |
Consent numbers link to the consent's documents in QLDC eDocs, which needs an eDocs sign-in.
From the documents of BC261528 read 18 Nov 2026
- Lodged by
- Not named on the application form
- Timber cladding
-
- • HERMPAC VERTICAL SHIPLAP WEATHERBOARD - BRANZ Appraisal
- All exposed sides of exterior and interior timber (except Cedar) shall be treated with one coat of paint (or clear coating) specified before fixing.
- All exposed sides of Cedar members shall be treated with one coat of finish specified before fixing.
- fixings dimensions and vertical shiplap timber framing manufacturer specification. Fix 2/90 x 45mm opening studs to all door openings except where otherwise specified. See
- Species: Alaskan Yellow Cedar Durability Class: Class1 Durability above ground
- Surface finish: Dressed face and sanded. Oil stain finish to match timber cladding. Dryden’s Wood-X Exterior oil – Pioneer : One coat only (due to high natural oil content in
- (C 14) VERTICAL SHIPLAP WEATHERBOARDS – WALL CLADDING Supply and install dressed Alaskan Yellow Cedar
- Profile No: CP1739 Vertical Shiplap Weatherboard – 115mm cover 140mm x 18.5mm thick, 6mm negative detail
- recommendations on the specific wood species of Alaska Yellow Cedar, only a single re- coating is required when ongoing maintenance is due.
- HERMPAC YELLOW CEDAR Product: Hermpac Yellow Cedar products
- Timber Species: Alaskan Yellow Cedar Origin : British Columbia and Alaska Canada
- HERMPAC - VERTICAL SHIPLAP TIMBER CLADDING Location: As per plans
- Species: Yellow Cedar Grade: HERMPAC Premium Clears No.1 (PC1)
- Profile type: Vertical Shiplap Cover dimensions: 115mm, 6mm negative detail, 140mm x 18.5mm finish
- Supply and install 180x28mm dressed Alaskan Yellow Cedar - Hermpac HP72 Fascia. Fix with Stainless Steel Hermpac 316 Stainless Steel rosehead nails (2 per fixing) at even
- Supply and install dressed Alaskan Yellow Cedar Grade PC1 timber ceiling panelling square negative Profile No: CP3356 110mm cover, 6mm negative detail
- Rusticated weatherboard Risk Matrix Calculation
- 1.1 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System is a cavity-based shiplap timber weatherboard external wall cladding system for residential and light commercial type
- 1.2 The system consists of vertically fixed Hermpac shiplap weatherboards, ventilated cavity battens, flashings and accessories and is finished with a premium penetrating oil, stain or an exterior paint
- 2.1 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System incorporating oil or stain finished Western Red Cedar, Yellow Cedar, and DuraLarch weatherboards and paint finished Yellow
- Cedar, DuraLarch and AshinDura weatherboards, has been appraised as an external wall cladding system for buildings within the following scope:
- 2.2 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System incorporating oil or stain finished weatherboards has also been appraised for weathertightness and structural wind loading
- VERTICAL SHIPLAP WEATHERBOARD
- SHIPLAP WEATHERBOARD CAVITY SYSTEM
- 2.3 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System incorporating paint finished Western Red Cedar weatherboards has been appraised as an external wall cladding system for
- 2.4 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System must only be installed vertically on vertical, flat surfaces.
- 2.5 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System is appraised for use with aluminium window and door joinery that is installed with vertical jambs and horizontal heads and
- sills. (Note: The Appraisal of the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System relies on the joinery meeting the requirements of NZS 4211 for the relevant Wind Zone or wind
- 3.1 In the opinion of BRANZ, the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System, if designed, used, installed and maintained in accordance with the statements and conditions of
- Shiplap Weatherboard Cavity System meets the requirements for loads arising from self-weight, wind, impact and creep [i.e. B1.3.3 (a), (h), (j) and (q)]. See Paragraphs 9.1-9.5.
- Shiplap Weatherboard Cavity System meets these requirements. See Paragraphs 10.1 and 10.2. Clause E2 EXTERNAL MOISTURE: Performance E2.3.2. The Hermpac VertiLine Vertical Shiplap
- Weatherboard Cavity System meets this requirement. See Paragraphs 14.1-14.5. Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1. The Hermpac VertiLine Vertical
- Shiplap Weatherboard Cavity System meets this requirement. Technical Specification
- Hermpac Shiplap Weatherboards ¬ Hermpac shiplap weatherboards are manufactured from Canadian Coastal Western Red Cedar
- andYellowCedar.SelectedweatherboardsarealsomanufacturedfromDuraLarchandAshinDura. ¬ The weatherboard lap and rebate profiles are in accordance with NZS 3617 and BRANZ
- ¬ The weatherboards are supplied minimum 18 mm thick, and are available in a range of widths and face profiles. They are supplied in random lengths up to 6.1 m. Lengths outside of the general
- ¬ Western Red Cedar and Yellow Cedar finger-jointed weatherboards (CedarOne and CedarLine) are minimum 17.5 mm thick, and are available in a range of widths and face profiles. They are
- ¬ Western Red Cedar, Yellow Cedar (including CedarOne and CedarLine) and DuraLarch weatherboards are supplied unfinished for site finishing with oil, stain or paint prior to
- AshinDura weatherboards are treated to Hazard Class H3.1 and must be paint finished only. They are supplied primed, or prefinished by Machinecoat NZ Limited. Refer to the Appraisals
- listing on the BRANZ website for details of the Hermpac shiplap weatherboard profiles covered by this Appraisal. (Note: This Appraisal is only valid when weatherboards with profiles as listed
- (Note: All timber accessories are manufactured from Canadian Coastal Western Red Cedar, Yellow Cedar or DuraLarch.)
- of the weatherboards at window and door jambs. The J Mould is available 20 and 29.5 mm wide with a 70 mm return and is supplied in 2.4 and 3 m lengths.
- Vertibat cavity battens 45 x 18 mm (V8 and V9) are available in Western Red Cedar (refer to BRANZ Appraisal No. 1189). The top and bottom edges are bevelled with a slope. The front and
- ¬ Hermpac oil or stain finished shiplap weatherboard fixings (for Vertibat battens fixed to dwangs) - silicon bronze, or Grade 316 stainless steel annular grooved Hermpac crown head, rose head or
- ¬ Hermpac oil or stain finished shiplap weatherboard fixings (for 40 or 45 mm Vertibat battens fixed to studs only) - silicon bronze, or Grade 316 stainless steel annular grooved Hermpac
- ¬ Hermpac paint finished shiplap weatherboard fixings - Grade 316 stainless steel annular grooved jolt head nails. The nail shank must be minimum 3.25 mm diameter and the length must
- ¬ Hermpac weatherboard screw fixing - Grade 316 stainless steel starcap screws to give a minimum 21 mm penetration of wall framing or structurally fixed cavity batten.
- 4.2 Accessories used with the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System which are supplied by the building contractor are:
- 4.3 Prior to the installation of oil or stain finished weatherboards, the back, face, ends and edges of the Hermpac shiplap weatherboards not supplied prefinished must be sealed with an exterior
- based penetrating stain must be used over the front face of the Hermpac shiplap weatherboards to protect the weatherboards and give the desired finish colour to the exterior walls. The oil or
- 4.4 Prior to the installation of paint finished weatherboards that are supplied unprimed, the back, face, ends and edges of the Hermpac shiplap weatherboards must be primed in accordance with the
- all bottom edges of Hermpac shiplap weatherboards and accessories not supplied prefinished, must be finished with at least two coats of an exterior grade paint complying with any of Parts 7, 8,
- 9 or 10 of AS 3730 to protect the weatherboards and give the desired finish colour to the exterior walls. The paint must be recommended for use as a wall cladding paint for the selected timber by the
- (Note: For Hermpac shiplap weatherboards, Hermpac recommends using paint with a colour that has a Light Reflectance Value (LRV) of ≥ 40% for Western Red Cedar, Yellow Cedar or AshinDura, or
- on-site or off-site, is under the control of the building contractor. Hermpac vertical shiplap weatherboards must be stacked flat and true, clear of the ground by a minimum of 150 mm and
- ends and the weatherboard surfaces. 5.2 Accessories must be stored so they are kept clean, dry and undamaged. All accessories must be
- ¬ VertiLine Vertical Shiplap Weatherboards Cavity System Installation Specifications, May 2022V2. ¬ All drawings referenced in HC-SHIP-000 and HC-SHIP-001, both issued 2022.
- 7.1 Timber wall framing behind the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System must be treated as required by NZBC Acceptable Solution B2/AS1.
- openings for the support and fixing of cavity battens and the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System.
- 7.4 Timber wall framing behind where weatherboards are joined over a cavity batten must be nominal 50 mm thickness (i.e. 45 mm minimum finished thickness).
- application. (Note: If Hermpac shiplap weatherboards are fixed to framing with a moisture content of greater than 24% problems may occur at a later date due to excessive timber shrinkage.)
- 8.1 When the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System is used for specifically designed buildings up to 2.5 kPa design differential ULS wind pressure, only the weathertightness
- 8.4 At balcony, deck or roof/wall junctions, the bottom edge of the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System must be kept above the top surface of any adjacent roof flashing by a
- Paragraph 9.1.3.4. Where rigid underlays are used, the weatherboard fixing lengths must be increased by a minimum of the thickness of the underlay.
- 9.1 The mass of the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System is less than 30 kg/m2
- 9.2 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System has good resistance to impact loads likely to be encountered in normal residential use. The likelihood of impact damage to the
- 9.3 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System incorporating oil or stain finished Cedar or DuraLarch weatherboards is suitable for use in all Wind Zones of NZS 3604,
- 9.4 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System incorporating paint finished DuraLarch, AshinDura and Yellow Cedar weatherboards is suitable for use in all Wind Zones of
- 9.5 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System incorporating paint finished Western Red Cedar weatherboards (fixed with jolt head nails) is suitable for use in NZS 3604
- 10.1 Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System installations are expected to have a serviceable life of at least 20 years provided the system is maintained in accordance with this
- Appraisal and the Hermpac shiplap weatherboards are continuously protected by a oil, stain or paint finish. (Note: For oil or stain finished weatherboards, this opinion only covers serviceability
- weatherboards in areas subject to microclimatic conditions requires specific design in accordance with NZS 3604, Paragraph 4.2.4, and is outside the scope of this Appraisal.
- western facing walls. When recoating, care must be taken to ensure bottom edges and shiplap edges are well covered and penetrated with the oil or stain.
- instructions. When repainting, care must be taken to ensure bottom edges and shiplap edges are well covered with the paint.
- stain or paint coatings, flashings or the weatherboards must be repaired in accordance with the relevant manufacturer’s instructions.
- term durability of the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System.) Control of External Fire Spread
- 12.2 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System has not been assessed for a peak heat release or total heat released rating and therefore cannot be used within 1 m of the
- 13.1 Separation or protection must be provided to the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System from heat sources such as fireplaces, heating appliances, flues and chimneys. Part
- 14.1 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System, when installed in accordance with this Appraisal and the Technical Literature, will prevent the penetration of moisture that could
- 14.3 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System allows excess moisture present at the completion of construction to be dissipated without permanent damage to building
- 14.5 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System, where there is a designed cavity drainage path for moisture that penetrates the cladding, does not reduce the requirements
- 15.2 The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System is not a barrier to the passage of water vapour, and when installed in accordance with this Appraisal will not create a risk of
- Shiplap Weatherboard Cavity System Technical Literature and this Appraisal by competent and experienced tradespersons conversant with the Hermpac VertiLine Vertical Shiplap Weatherboard
- Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System Installation Wall Underlay and Flexible Sill and Jamb Tape Installation
- installationofthecavitybattensandtherestoftheHermpacVertiLineVerticalShiplapWeatherboard Cavity System. Flexible wall underlay must be installed horizontally and be continuous around
- for paint finished Western Red Cedar weatherboards fixed with jolt head nails.) The battens must be installed with the top edge sloping away from the wall underlay towards the back of the
- weatherboards. The cavity battens must be fixed in place with 40 x 2.5 mm flat head hot-dip galvanised nails or 50 x 2.87 mm hot-dip galvanised gun nails (for 20 mm thick battens), or 60 x
- Vertibat cavity batten spacings for paint finished Western Red Cedar weatherboards fixed with jolt head nails.) The battens must be installed with the top edge sloping away from the wall
- underlay towards the back of the weatherboards. The cavity battens must be fixed in place with one 12 g x 65 mm long Grade 304 stainless steel screw at each stud crossing (maximum 600 mm
- Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System Installation 17.4 Hermpac shiplap weatherboards may be cut on-site by power or hand saw. Holes and cut-outs may
- 17.5 Hermpac shiplap weatherboards must be dry prior to installation. 17.6 Before oil or stain finished Hermpac shiplap weatherboards are installed, the back, face and edges
- 17.7 Before paint finished Hermpac shiplap weatherboards are installed, the back, face and edges must be primed with an exterior grade primer. During the installation of paint finished Hermpac shiplap
- weatherboards, cut ends must be sealed with two coats of an exterior grade alkyd timber primer. 17.8 Before the weatherboards are installed, the corner detail must be prepared to suit the selected
- be installed before commencing weatherboard fixing and the cavity closure must be installed continuously around the bottom of the cavity.
- 17.9 Hermpac shiplap weatherboards must be installed starting at the corner of the wall section being clad. The first weatherboard must be installed plumb to assist with the installation of subsequent
- weatherboards. The weatherboards must overhang the bottom plate by a minimum of 50 mm. The weatherboards should be installed with the lap facing away from the prevailing winds.
- 17.10 Immediately prior to installing the weatherboards over the internal and external corner flashings, a continuous bead of sealant must be applied to the face of the flashing along the fixing line.
- 17.11 Hermpac shiplap weatherboards must be overlapped a minimum of 25 mm, with an expansion gap of 2 mm at the overlap. In NZS 3604 Wind Zones up to, and including, Very High, it is recommended
- that the top of the weatherboard lap is restrained using the Hermpac clinch nail at every cavity batten. Hermpac clinch nails must be used to restrain the top of the weatherboard lap in the Extra
- 17.12 Fix weatherboards in full lengths where possible. Where joints are unavoidable, scarf the weatherboard at 30° over a cavity batten and fix with one fixing through the overlapping board.
- Nail-Fixing Weatherboards 17.13 Hermpac shiplap weatherboards must be pre-drilled with a hole diameter slightly smaller than that
- of the nail. Each weatherboard is to be fixed with one nail per board at every cavity batten. 17.14 For nail-fixing of the weatherboards, silicone bronce or Grade 316 stainless steel annular grooved
- 17.15 Fixing must be located 30-35 mm in from the weatherboard lap and a minimum of 32 mm from the end of the board. Crown head, rose head or flat head nails must finish flush onto the surface
- of the weatherboard, not into or below the surface. Nails must be installed with a slight upslope to reduce capillary draw. Jolt head nails must be punched a maximum of 2 mm beneath the surface
- Screw-Fixing Weatherboards 17.16 Hermpac shiplap weatherboards must be pre-drilled with a hole diameter slightly smaller than
- that of the screw. Each weatherboard is to be fixed with one screw per board at every cavity batten. 17.17 For screw fixing of the weatherboards, Grade 316 stainless steel Hermpac starcap screws must
- 17.18 Fixing must be located 30-35 mm in from the weatherboard lap and a minimum of 32 mm from the end of the board. The base of the screw head must finish flush onto the surface of the
- weatherboard, not into or below the surface. Readers are advised to check the validity of this Appraisal by
- 17.21 To prevent swelling of the weatherboard around punched fixings, the fixing must be filled immediately, or alternatively the weatherboard and the head of the fixing must be primed with a
- the paint finish. Hermpac shiplap weatherboards must be painted as soon as practicable following fixing and must be clean and dry before commencing. If the Hermpac shiplap weatherboards are
- Shiplap Weatherboard Cavity System installations. Health and Safety
- 18.1 Cutting of Hermpac shiplap weatherboards must be carried out in well ventilated areas and dust masks, eye and hearing protection must be worn.
- Vertical Shiplap Weatherboard Cavity System are provided in the relevant manufacturer’s Technical Literature.
- ¬ BRANZ expert opinion on NZBC E2 code compliance for the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System is based on testing and evaluation of all details within the scope
- and as stated within this Appraisal. The Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System was tested to NZBC Verification Method E2/VM1. The testing assessed the performance
- based weatherboard claddings. ¬ Fastener pull through testing. BRANZ determined design wind suction pressures, and by
- 20.2 The performance of timber weatherboard wall cladding products in New Zealand has been considered, including the structural and durability performance, and non-hazardous nature.
- 20.4 The Technical Literature for the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System has been examined by BRANZ and found to be satisfactory.
- 21.1 The manufacture of Hermpac shiplap weatherboards has been examined by BRANZ, including methods adopted for quality control. Details regarding the quality and composition of the materials
- battens and the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System in accordance with the instructions of Hermpac.
- 21.5 Building owners are responsible for the maintenance of the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System in accordance with the instructions of Hermpac.
- ¬ BRANZ Bulletin Number 411, April 2001, Recommended Timber Cladding Profiles. ¬ NZS 3602:2003 Timber and wood-based products for use in building.
- ¬ NZS 3617:1979 Specification for profiles of weatherboards, fascia boards and flooring. ¬ NZS 4211:2008 Specification for performance of windows.
- This Appraisal has been amended to remove reference to Cavibat cavity battens, add Yellow Cedar back into the Appraisal, add CedarOne and CedarLine, add the option of screw-fixing of the weatherboards and
- adjust the minimum thickness of the weatherboards. Readers are advised to check the validity of this Appraisal by
- In the opinion of BRANZ, the Hermpac VertiLine Vertical Shiplap Weatherboard Cavity System is fit for purpose and will comply with
- VertiLine Vertical Shiplap Weatherboard CavitySystem
- The VertiLine Vertical Shiplap Cavity System is a cavity- based external wall cladding system for residential and light
- shiplap timber weatherboards installed over ventilated battens, flashings and accessories and is finished with a
- The VertiLine Vertical Shiplap Cavity System has been appraised by BRANZ. Refer to Appraisal No. 650 (2020).
- The VertiLine Vertical Shiplap Cavity System has the Codemark Certificate of Conformity. Refer Certificate No.
- 1.4 Hermpac Vertical Shiplap Weatherboards Hermpac vertical shiplap weatherboards are manufactured
- from Canadian Coastal Western Red Cedar and Yellow Cedar. Selected weatherboard profiles are manufactured
- The weatherboard lap and rebate profiles are in accordance with NZS 3617 and BRANZ Bulletin 411. The
- weatherboards are available in a range of sizes and face profiles. They are supplied as a random length supply. Select
- The VertiLine Vertical Shiplap Cavity System uses Vertibat timber cavity battens to separate the weatherboards from
- to provide support for the weatherboards at fixings points. The 40 and 45mm thick Vertibat battens can be structurally
- weatherboards are then fixed into the batten only. Cavity battens are Vertibat 45 x 18mm (V8/V9) Western Red
- Cedar, 45 x 20mm (V1), 45 x 40mm (V3), 45 x 45mm (V5), 70 x 20mm (V2), 70 x 40mm (V4), 70 x 45mm (V6) thick Radiata
- Cedar Horizontal Cavity Battens. 1.6 Accessories
- VertiLine Vertical Shiplap Cavity System include: • Hermpac external corner mouldings – HP40 (40 x
- • Nail fixing - Oil/Stain finished weatherboard fixing – Silicon Bronze or Grade 316 Stainless Steel annular
- • Screw fixing - Oil/Stain finished weatherboard fixing- Grade 316 Stainless Steel or Bronzed Stainless Hermpac
- Shiplap weatherboards must be screw fixed. • Paint finished weatherboard fixings – Grade 316
- Hermpac vertical shiplap weatherboards must be stacked flat and true, clear of the ground by a minimum of
- The weatherboards must be kept dry at all times either by storing within an enclosed building or when stored
- damage to edges, ends and the weatherboard surfaces. Water must not be allowed to enter the stack.
- Shiplap Cavity System as an external vertically fixed wall cladding system for buildings within the following scope:
- All oil/stain finished Hermpac weatherboards fixed with crown/rose/flat head nails or Starcap screws. Paint finished
- Yellow Cedar, and AshinDura weatherboards fixed with annular grooved jjolt/crown/rose or flat head nails.
- Paint finished Western Red Cedar weatherboards fixed with annular grooved crown/rose/flat head nails:
- Any oil/stain or paint finished weatherboards if fixed with annular grooved flat/crown/rose head nails, or Starcap
- Paint finished Western Red Cedar weatherboards (including CedarOne/CedarLine) fixed with annular grooved jolt head
- The VertiLine Vertical Shiplap Cavity System if designed, used and installed in accordance with the statements and
- Hermpac weatherboards must overhang the floor structure by a minimum of 50mm as required by NZBC Acceptable
- The bottom edge of the VertiLine Vertical Shiplap Cavity System must finish a minimum of 100mm above paved
- of the Hermpac weatherboards must be kept clear of any adjacent surface, or above the top surface of any
- Timber wall framing behind the VertiLine Vertical Shiplap Cavity System must be treated as required by NZBC
- Note: For paint finished Western Red Cedar weatherboards (including CedarOne/CedarLine) fixed with annular
- The VertiLine Vertical Shiplap Cavity System must incorporate a cavity closure strip to close off the bottom of the cavity and
- The VertiLine Vertical Shiplap Cavity System must be installed over wall underlay complying with NZBC Acceptable Solution
- underlays are used, the weatherboard fixing lengths must be increased by a minimum of the thickness of the underlay.
- 2.10 Hermpac Vertical Shiplap Weatherboards The weatherboards shall be pre-coated with the selected
- Pre-finished vertical shiplap weatherboards shall be over- coated and maintained in accordance with the coating
- The weatherboards shall be fixed to nogs/dwangs (or structurally fixed to 40-45mm Vertibat cavity battens) at 400-
- 480mm maximum centres using Hermpac shiplap weatherboard fixings (refer to Section 1.5 of this
- the rest of the VertiLine Vertical Shiplap Cavity System. Flexible building underlay must be installed horizontally and
- weatherboards is maintained at all times. There are several options available for the installation of
- the back of the weatherboards. The cavity battens must be fixed in place with 40 x 2.5mm flat head hot-dipped
- underlay towards the back of the weatherboards. The cavity battens must be fixed in place with one 12gauge x 65mm long
- 3.1.2 Hermpac Vertical Shiplap Weatherboard Installation Hermpac vertical shiplap weatherboards must not be wet
- edges of the weatherboards to be sealed with an exterior grade oil-based penetrating oil/ stain or paint. During
- Hermpac shiplap weatherboards must be installed starting at the corner of the wall section being clad. The first
- weatherboard must be installed plumb to assist with the installation of subsequent weatherboards. The weatherboards
- weatherboards should be installed with the lap facing away from the prevailing winds.
- Immediately prior to installing the weatherboards over the internal and external aluminium corner flashings, a continuous
- Hermpac shiplap weatherboards must be overlapped 25mm with an expansion gap of 2mm at the overlap.
- gap between weatherboards at the back of the board. Clinch nails are a proprietary component of this cladding
- Hermpac shiplap weatherboards must be pre-drilled on a slight up-slope, with a hole slightly smaller than that of the
- fixing. Fix each weatherboard with one nail/screw per board at every cavity batten.
- The fixing must be located 30-35mm in from the weatherboard lap, be located no closer than 32mm (where practical) from
- the end of the board. Fix weatherboards in full lengths where possible. Where joints are required, scarf the weatherboard at
- Nail fixing - oil/stain finished weatherboards Weatherboard fixings must be either Silicon Bronze or Grade
- batten. Finish flush onto the surface of the weatherboard, not into or below the surface.
- Nail fixing - paint finished weatherboards Weatherboard fixings must be Grade 316 Stainless Steel
- weatherboard surface, prime nail holes and fill prior to sanding and finishing.
- finished weatherboards, refer to fixing clause above. Hermpac recommend the use of paint quality profiled
- weatherboards. Please ensure (PQ) profiles are ordered. Paint quality profiles are machined with a dressed face and
- Screw Fixing oil, stain or paint finished weatherboards Weatherboard fixings must be Grade 316 Stainless Steel or
- onto the surface of the weatherboard, not into or below the surface. NB: Kanda Vertical Shiplap weatherboards must
- of any butted weatherboard and direct to flashing along the line of weatherboard nail fixing (if the weatherboard fixing
- front faces and edges of the weatherboards to protect the weatherboards and give the desired finish colour.
- weatherboards to protect the weatherboards and give the desired finish colour.
- weatherboard profile/s will be paint quality (PQ) and the process below followed:
- VertiLine Vertical Shiplap Cavity System. Annual inspections must be made to ensure that all aspects of the cladding
- weatherboards must be repaired in accordance with the relevant manufacturer’s instructions.
- ensure bottom edges and shiplap edges are well covered and penetrated with the stain.
- Cutting of Hermpac shiplap weatherboards must be carried out in well ventilated areas and dust masks, eye and hearing
Project Specification (PDF, 26.8MB)
Lines of the assessment, plans or specification that mention timber cladding. Some describe what the neighbourhood rules allow rather than what is proposed.
- Not read
- BC Application is not a Form 2